Page 2 - — Introduction; Ceiling DocCam II; — Table of Contents; ii; providing accurate document positioning.; Single cable; carrying power, video and control, simplifying installation and; IR remote; that allow the Ceiling DocCam II to respond to different; Services and support; Ceiling DocCam IITM User Manual; Technical support; Table of Contents
Ceiling DocCam II — Introduction 1 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Ceiling DocCam II — Table of Contents ii Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 The Ceiling DocCam™ II is a ceiling-mounted document camera that displays images on monitors, ...
Page 3 - Important safeguards; unauthorized power supply will void any and all warranties.; Attention; Unpacking; Figure 1. Unpacking items; CAUTION
Ceiling DocCam II — Introduction 3 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Ceiling DocCam II — Introduction 2 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Important safeguards • Read and understand all instructions before using. • Do not operate the Ceili...
Page 4 - Front and back wall plate connections; Product overview; Camera enclosure; DIP switches; Figure 2. Front and back of camera enclosure and trim ring
Ceiling DocCam II — Introduction 5 Front and back wall plate connections A. RJ-45 Connector. The RJ-45 jack connects to the RJ-45 connector on the camera enclosure using a Cat. 5 cable. B. 15 VDC . The 15 VDC power supply jack. C. Composite. This output jack allows the Ceiling DocCam II to be connec...
Page 5 - Remote; Before you install; Figure 5. Complete installation; Installation; Figure 4. ClearOne remote
Ceiling DocCam II — Installation 7 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Ceiling DocCam II — Introduction 6 Remote A. Flip . Rotates image 180º on video display device. B. Freeze. Freezes current image until you press again to release and return to live view. C. Focus. Foc...
Page 6 - — Installation; Connecting cables; To connect to the wall plate; Note; : For display devices that do not have; : Use only the power supply; Figure 9. Enclosure with back of wall plate; Figure 10. Connection to a video codec; To mount the camera; If the positioning indicator is; Figure 8. Enclosure and trim ring side view
Ceiling DocCam II — Installation 9 Ceiling DocCam II — Installation 8 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Connecting cables A single RJ-45 cable connects to the back of the wall plate providing S-video, com...
Page 7 - Programming presets; : These presets will only work with the ClearOne IR remote.; To program a preset; Configuring for remote controls; : After changing the DIP switches, camera must be power cycled.; Figure 11. DIP switch configurations
Programming presets Presets are used to program defined positions of the camera into a simple, one button preset.You can switch easily from a zoomed in position on a small document to a zoomed out position for documents such as blueprints. This saves the hassle of zooming in and out when presenting ...
Page 8 - Custom cable information; Viewing areas; — Operation; Using your codec remote; To zoom; When the zoom indicator passes the; To focus an image; Operation; Figure 14. Cable pinouts
Custom cable information If you need a longer cable, for best performance use a Cat. 5E or Cat. 6 cablewith a 200' maximum and 24 AWG. Usethe following pinouts for the Cat. 5 or Cat.6 cable. 13 12 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Ceiling DocCam II — Operation Technica...
Page 9 - Problem; Troubleshooting
Ceiling DocCam II — Appendix 15 Ceiling DocCam II — Troubleshooting 14 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Specifications Dimensions (Height x Diameter) Enclosure: 4.5" x 6.5" (11.43 x 16.51 cm) Cei...
Page 10 - Warranty; Product Return and Repair
Ceiling DocCam II —Appendix 17 Ceiling DocCam II — Appendix 16 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 NO OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MER-CHANTABILITY OR FITNESS FOR ANY PARTICULAR USE, APPLIES TO THE PRODUCT.MANUFACTURER’S MAXIMUM LIABILITY H...
Page 12 - Command execution cancel; VISCA Command/ ACK Protocol; RS-232 control information; Overview of VISCA; Command and inquiry
Ceiling DocCam II — Appendix 21 Ceiling DocCam II — Appendix 20 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 • Error message When a command or inquiry command could not be executed or failed, an error message isreturned instead of the completion message. Command execution cancel ...
Page 13 - — Appendix; Command List; VISCA Camera-Issued Messages; ACK/Completion Messages
Ceiling DocCam II — Appendix 23 Ceiling DocCam II — Appendix 22 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Command List Command Set Command Command Packet Comments Address Set Broadcast 88 30 01 FF IF_Clear Broadcast 88 01 00 01 FF CommandCancel 81 2p FF p: Socket No.(=1or2) CA...
Page 16 - Inquiry Command
Ceiling DocCam II — Appendix 29 Ceiling DocCam II — Appendix 28 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Inquiry Command Command Packet Inquiry Packet Comments 90 50 02 FF CAM_SpotAE PosInq 90 50 0p 0q 0r 0s FF pq: X positionrs: Y position 81 09 04 29 FF 90 50 00 00 0p 0q FF ...
Page 17 - Block Inquiry Command List
Ceiling DocCam II — Appendix 31 Ceiling DocCam II — Appendix 30 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Comments 0 0 0 0 Bit Byte 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 8 9 10 11 Focus Position (LL) 0 0 0 0 0 0 0 0 0 0 0 0 Focus Position (HH) Focus P...
Page 21 - VISCA Command Setting Values; Exposure control
Ceiling DocCam II — Appendix 39 Ceiling DocCam II — Appendix 38 Exposure control Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Bright 1F 1E 1D 1C 1B 1A 19 18 17 16 15 14 13 12 11 10 0F 0E 0D 0C 0B 0A IRIS F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F1.6 F...
Page 22 - Lens Control
Ceiling DocCam II — Appendix 41 Ceiling DocCam II — Appendix 40 Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Lens Control Others Title Setting Zoom Position Focus Position Focus Near Limit to 4000 0000 Wide End Optical Tele End to 7700 (77C0) a) Digital Tele End 1000 Far End to C...