Page 3 - Supports the remote unit in wall-mounting; BEFORE YOU BEGIN; Assign different channels to different remote units.; BATTERY AND CHANNEL
3 EN H Wall-mount holder Supports the remote unit in wall-mounting I Removable table standFor standing the remote unit on a flat surface BEFORE YOU BEGIN To ensure proper functioning of the EMR812HGN follow this setupprocedure. For best operation: 1. Assign different channels to different remote uni...
Page 4 - EN Follow these steps to install / replace batteries:; Remove the screws on the battery compartment.; Select the channel number on the CHANNEL slide switch.; Select the temperature display unit on the; BATTERY INSTALLATION: MAIN UNIT; Follow these steps to install / replace batteries:; Slide open the battery compartment door.
4 EN Follow these steps to install / replace batteries: 1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the ° C/ ° F slide switch. 4. Insert the batteries strictly according to the polarities shown t...
Page 5 - GETTING STARTED; To force a signal search:; HOW TO CHECK REMOTE AND; Icon; To display temperature / humidity readings from the main unit:; displayed in the box under the kinetic-wave.; HOW TO READ
5 EN GETTING STARTED Once batteries are placed in a given remote sensor unit, it will starttransmitting information at 40-second intervals. Also, for approximately a 3-minute duration, the main unit willautomatically search for signals once batteries are installed. Uponsuccessful reception, the indi...
Page 6 - To activate the remote-sensor scanning mode:
6 EN The unit is in searching mode. Transmission data are securelyregistered. No signals. THE COMFORT-LEVEL ICONS The comfort level is based on the recorded relative humidity. Anindicator will be displayed ot show if the level is comfortable, wet ordry. TEMPERATURE AND HUMIDITY TREND INDICATORS The ...
Page 7 - To deactivate the remote-sensor scanning mode:; MAXIMUM AND MINIMUM; To display the maximum and minimum display memory:; TEMPERATURE/HUMIDITY ALARM; Sequence; To set a high or low temperature or humidity alarm:; Press to set the temperature or humidity limit. Each press will
7 EN To deactivate the remote-sensor scanning mode: ◊ Press any button. MAXIMUM AND MINIMUM TEMPERATURE AND HUMIDITY The maximum and minimum recorded temperature and humidityreadings will automatically be stored in the memory. To display the maximum and minimum display memory: 1. Select the channel ...
Page 8 - The temperature range is from -50; To disable a sounding alarm:; DISCONNECTED SIGNALS
8 EN Note: The temperature range is from -50 ° C (-58 ° F) to +70 ° C (158 ° F). If this is the first time you set the limits, the lower limit will startfrom -50 ° C (-58 ° F) and the upper limit +70 ° C (158 ° F). Otherwise, the reading will start from the temperature lastselected. The humidity ran...
Page 9 - Main unit; Remote unit; Table Stand
9 EN TRANSMISSION COLLISION Signals from other household devices, such as door bells, homesecurity systems and entry controls, may interfere with those of thisproduct and cause temporarily reception failure. This is normal anddoes not affect the general performance of the product. Thetransmission an...
Page 11 - CAUTION
11 EN General RF Transmission Frequency : 433 MHz No. of Remote unit : Maximum of 3 RF Transmission Range : Maximum 30 meters Temperature compensation : 0.1 ° C to ( 0.2 ° F) Temperature sensing cycle : around 40 seconds Power Main unit : 2 pcs UM-3 or “AA” 1.5Valkaline batteries Remote sensing unit...
Page 12 - EC-DECLARATION OF CONFORMITY; ABOUT OREGON SCIENTIFIC
12 EN EC-DECLARATION OF CONFORMITY This product complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / ECDirective, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.1.a of the R&TTE Directive) Appl...