Page 2 - Barometer and Weather Forecast Device
EN 2 A weather forecast device, the EB833 uses barometricinformation to make forecasts as sunny, slightly cloudy,cloudy, and rainy. It also has a built-in thermometer. As a timepiece, this unit functions as a clock / calendar,daily alarm, and count-up timer. To optimize the usefulness of this device...
Page 4 - GENERAL OPERATION OF THE ALTIMETER; To view display sequences in Altimeter Mode:; BATT; NOTE
EN 4 GENERAL OPERATION OF THE ALTIMETER In Altimeter Mode, by detecting changes in air pressure,t h e E B 8 3 3 d e t e r m i n e s a g i v e n a l t i t u d e l e v e l .Subsequently, the unit can be set to show changes inaltitude and maximum / minimum elevations. It can storealtitude-related data ...
Page 5 - * Previous altitude levels can be displayed for up to; Altitude Alarm Display.
EN 5 2. Press [ALT] to view the Altitude Max Memory Display. Display shows: 3. Press [ALT] again, to view the Altitude Min Memory Display. Display shows: 4. Press [ALT] again, Altitude History Display. Display show: * Previous altitude levels can be displayed for up to 12-hours. Press [+] or [-] to ...
Page 6 - ALTITUDE CALIBRATION; To calibrate the altitude:; Point C: A point where the altitude, as indicated by a; The unit will return to Normal Altimeter Display if; UNITS OF MEASUREMENT FOR ALTITUDE; To change the altitude units of measure:; select between meters or feet.; ABOUT THE ALTITUDE CHANGE GRAPH
EN 6 ALTITUDE CALIBRATION If the altitude on the display is different from the actualcurrent altitude, the unit can be manually calibrated toreflect the true altitude level. To calibrate the altitude: 1. In Normal Altitude Display.2. Press and hold [ALT] and [TIME] simultaneously for about 2 seconds...
Page 7 - To clear the maximum altitude reached memory,; To clear Altitude Mode Memories:; To bypass any section without making changes; ALTITUDE HISTORY DISPLAY; To numerically display previous altitude levels:; history for a specified time period up to –12 hours.; ABOUT ALTITUDE CHANGE MEMORY; Point A: At this point, reset the Altitude Change Memory
EN 7 Point B: At this point, check the Altitude Change Memory. The unit will display the net vertical differencebetween point A and point B. CLEARING ALTITUDE MEMORY, MAX / MINALTITUDE MEMORY, AND VERTICALASCENT / DECENT MEMORY Altitude related memories are cleared sequentially. Duringthe sequence, ...
Page 8 - ALTITUDE SAMPLING RATE; THE ALTITUDE ALARM; ALTALARM
EN 8 activate at the specified elevation. 7. Press [ALT] again and the Altimeter exits the setting sequence. If the alarm is set to activate at a specifiedaltitude, the will be displayed. NOTE The unit will return to the Altimeter Display if no buttons are pressed for 2 minutes.The altitude alarm se...
Page 10 - BAROMETRIC CALIBRATIONS
EN 10 To View Different Displays in Barometric Mode: 1. Press [BARO] to move between barometric functions. Normal Barometric Display The first display in Barometric Display Mode. NOTE The unit will automatically enter Normal Barometric Display when first entering the Barometric Mode.Display shows: 2...
Page 11 - PRESSURE HISTORY DISPLAY; pressure for the specified time period.; NOTES ON THE BAROMETER FUNCTIONS; Simultaneously press again until the desired units; ABOUT THE PRESSURE CHANGE GRAPH
EN 11 PRESSURE HISTORY DISPLAY Barometric pressure readings can also be displayednumerically. To numerically display previous barometric pressurelevels: 1. Enter Barometric History Display.2. Press [+] or [-] to display the corresponding barometric pressure for the specified time period. NOTES ON TH...
Page 12 - Enter Normal Altimeter Display or Normal Barometer; Normal Time Display; The first display in Time and Date Mode.
EN 12 2. Press [TIME] to view the Current Date / Month Display. Display shows: 3. Press [TIME] again to view the Alarm Time Display Display shows: 4. Press [TIME] again to view the Timer Display Display shows: GENERAL OPERATION OF THE TIME ANDDATE FUNCTIONS The EB833 has a Time and Date Mode. This m...
Page 13 - TIME AND DATE; The current time and date can be set sequentially.; To Set the Current Date and Time:; Enter Normal Altitude Display or Normal Barometer; The unit will return to Normal Barometer Display; DAILY ALARM; To Set the Alarm Time:
EN 13 TIME AND DATE The current time and date can be set sequentially. To Set the Current Date and Time: 1. Enter Normal Altitude Display or Normal Barometer Display. 2. Press and hold [TIME] for 2 seconds, the EU or US indicator starts flashing. 3. Press [+] or [-] to select US for US format shown ...
Page 14 - indicator stops flashing.; If no buttons are pressed for 2 minutes during; DEACTIVATING THE ALARM; Pressing any button can stop the alarm sound.; TEMPERATURE DISPLAY; change the units of measure.; RESETTING THE UNIT; After resetting the unit all memories and data will
EN 14 6. Press [TIME] again to set and activate / deactivated the alarm. 7. Press [+] or [-] to select between activation and deactivation. The alarm icon will only appear whenthe alarm is set. 8. Pressing [TIME] a last time to exit. The ALARM indicator stops flashing. NOTE If no buttons are pressed...
Page 15 - Altimeter Functions
EN 15 MAINTENANCE When handled properly, this unit is engineered togive you years of satisfactory service. Here are a fewproduct care instructions: 1. Do not immerse the unit in water. If the unit comes in contact with water, dry it immediately with a soft lint-free cloth. 2. Do not clean the unit w...
Page 16 - CAUTION
EN 16 Resolution 0.1 ° C (0.2 ° F) Sampling rate 10 seconds Units of measure ° C or ° F Calendar Clock Functions Calendar Date/month (Europeanformat) or month/Date(US format) Clock time 12-hour AM /PM format or24-hours format Time resolution 1 second Timer Functions Range counts up to 99 hours,59 mi...
Page 17 - ABOUT OREGON SCIENTIFIC; OR
EN 17 ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learnmore about Oregon Scientific products such as digitalcameras; MP3 players; children's electronic learningproducts and games; projection clocks; health and fitnessgear; weather stations; and digital and conferencephone...
Page 19 - User Manual
EN 19 Altimeter / Barometer With Weather Forecasts And Clock / Calendar Model: EB833 User Manual EB833(EN3) 8/31/04, 3:40 PM 19