Page 3 - – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY,; ) Ducted fans must be vented to the outside.; WARNING; – TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE; power from switching on accidentally.
1 IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicab...
Page 4 - CAUTION
2 What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT ...
Page 5 - COMPONENTS OF PACKAGE; (Must keep all material for returns or refunds); Range Hood Box
3 COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) Range Hood Box RA9430SQB Model No. RA9430SQB RA9436SQB KOBE Range Hood – 1 Warranty Registration Card – 1 Instructions Manual – 1 Hood-Mounting Bracket – 2 Screws Package – 1 *Attached to Hood Baffle Filter – 2 Baffle Handle – 2...
Page 6 - INSTALLATION; PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING; TABLE 1; SAFETY WARNING
4 INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate the length of the installation, please refer to Table 1. (All calculations are measured in inches.) TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) ...
Page 8 - Duct Cover Installation; Align the inner duct cover to the duct; Figure 5
6 4. Secure and tighten the mounting screws. CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING. Ductwork Installation 5. Using Reference E from Table 1 and measurements on Page 11, mark the leveling point for duct cover-mounting bracket. 6. Secure the duct cover-mounting bracket to the wall wit...
Page 9 - Fasten outer duct cover to plastic plate on; Install Accessories; all lights and fan operation.
7 inner duct cover with two (4x8 mm) screws (provided). 12. Fasten outer duct cover to plastic plate on the hood with four (4x8 mm) screws (provided). Install Accessories 13. Place baffle filters underneath the hood. Refer to Figure 10. Final Assembly 14. Turn power ON in control panel. Check all li...
Page 11 - MAINTENANCE; To Clean Baffle Filter
9 MAINTENANCE For the optimal level of operation, clean the range hood surface and filters regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. Regular care will help preserve your KOBE Range Hood’s fine appearance. 1. Use only mild soap or detergent. Dry surface u...
Page 12 - SPECIFICATIONS; Commercial Grade Stainless Steel
10 SPECIFICATIONS MODEL / SIZE RA9430SQB / 30" RA9436SQB / 36" COLOR Commercial Grade Stainless Steel CONSUMPTION / AMPERE RA9430SQB - 215W / 1.79A RA9436SQB - 215W / 1.79A VOLTAGE 120V 60Hz NUMBER OF MOTORS 1 DESIGN 18-Gauge Seamless / Satin Finish MOTOR TYPE Squirrel Cage EXHAUST Top 6"...
Page 13 - MEASUREMENTS & DIAGRAMS
11 MEASUREMENTS & DIAGRAMS Front View Bottom View 36" Hood 30" Hood
Page 14 - PARTS LIST
12 PARTS LIST MODEL NO.: RA9430SQB RA9436SQB NO. DESCRIPTION MODEL / SIZE PART NO. 1 Duct Cover-Mounting Bracket C1-0203-0092 2 Duct Cover RA9236DC B102-0192 3 Plastic Plate C1-0506-0092 4 6” round Plastic Exhaust C1-0505-0001 5 Hood-Mounting Bracket C1-0221-0001 6 Rubber Stand C1-0510-0101 7 Hood C...
Page 16 - CIRCUIT DIAGRAM
Page 17 - DISCLAIMER; DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR WARRANTY.
15 DISCLAIMER 1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM. Upon acceptance of items, owner assumes responsibility for its safe arri...
Page 18 - WARRANTY; WARRANTY CERTIFICATE; for failure of light bulbs or heat lamps
16 WARRANTY WARRANTY CERTIFICATE KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement...
Page 20 - PRODUCT REGISTRATION
18 PRODUCT REGISTRATION Register Your Product! Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired or at our option the unit will be replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE ...
Page 21 - KOBE Range Hoods
19 KOBE Range Hoods 10505 Valley Blvd Suite # 302 El Monte, CA 91731 USA http://www.KOBERangeHoods.com This KOBE hood is manufactured for use in the USA and CANADA only. We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that...