Page 2 - CONTENTS; Important Safety Instructions.........................................................................; - READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -
- READ AND SAVE THESE INSTRUCTIONS - CONTENTS Important Safety Instructions………………………………………………………………. Components of Package…………………………………………………………………… Installation…………………………………………………………………………………… Operating Instructions.…………………………………...………………………………… Maintenance…………………………………………………………………………………. Specifica...
Page 3 - IMPORTANT SAFETY INSTRUCTIONS; - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -; WARNING
1 IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicab...
Page 5 - COMPONENTS OF PACKAGE; ( M u s t k e e p a ll m a t e r ia l f o r re t u r n s o r r e f u n d s ); Range Hood Box
3 COMPONENTS OF PACKAGE ( M u s t k e e p a ll m a t e r ia l f o r re t u r n s o r r e f u n d s ) Range Hood Box Duct Cover Box (Sold Separately) {A} KOBE Range Hood {B} Warranty Registration Card {C} Instructions Manual {D} Vent Cover (Top) {E} Oil Containers (Round) {F} Oil Containers (Oval) {A...
Page 6 - INSTALLATION
4 INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation Calculate the length of the installation, before installing the hood. (All calculation is measure in inches.) - FOR UNDER THE CABINET - TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Count...
Page 7 - S A F E T Y W A R N I N G
5 S A F E T Y W A R N I N G HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. Installation Contents UNDER THE CABINET Top Vent……...
Page 8 - UNDER THE CABINET INSTALLATION – TOP VENT
6 UNDER THE CABINET INSTALLATION – TOP VENT Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. - A straight, short venting run will allow the hoo...
Page 10 - UNDER THE CABINET INSTALLATION – REAR VENT
8 UNDER THE CABINET INSTALLATION – REAR VENT Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from the hood to the outside. Refer to Figure 6. - A straight, short venting run will allow the ho...
Page 12 - STAND ALONE INSTALLATION – TOP VENT
10 STAND ALONE INSTALLATION – TOP VENT ***This installation only applied with the purchase of an optional duct cover (Model No. CH1120DC). Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from...
Page 15 - STAND ALONE INSTALLATION – REAR VENT
13 STAND ALONE INSTALLATION – REAR VENT ***This installation only applied with the purchase of an optional duct cover (Model No. CH1120DC). Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe fro...
Page 19 - OPERATING INSTRUCTIONS; Speed Control A
17 OPERATING INSTRUCTIONS This KOBE hood is equipped with four electronic controls with a 10-second standby startup & 30-second delay shutoff, two powerful centrifugal turbine impellers with safety screens, two bright 12-volt 20-watt halogen lights, and four oil containers. The four control butt...
Page 20 - Top rack dishwasher safe.
18 MAINTENANCE CAUTION: NEVER PUT YOUR HAND INTO THE AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For the optimal level of operation, clean the range hood surface, safety screens, and oil containers regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regul...
Page 21 - To Replace Light Bulb; CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.; maximum. Refer to Figure 34. Push bulb securely into light socket.
19 To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL. 1) Make sure all control switches are off, and range hood is unplugged. 2) Use a flat head screwdriver to pop out the protective covering as shown in Figure 33. 3) Gently pull out the defective light bulb and d...
Page 22 - SPECIFICATIONS
20 SPECIFICATIONS MODEL / SIZE CH7930SQ / 30” CH7936SQ / 36” CH7942SQ / 42” CH7948SQ / 48” COLOR # 304 Commercial Grade Stainless Steel VOLTAGE 120V 60Hz NUMBER OF MOTORS 2 DESIGN 18-Gauge Seamless / Satin Finish FAN TYPE Twin Turbine Impeller EXHAUST Top – 6” Round 7” Round 3-1/4” x 10” Rectangular...
Page 23 - MEASUREMENTS & DIAGRAMS
21 MEASUREMENTS & DIAGRAMS ***All inch measurements are converted from millimeters. Inch measurements are estimated. ***All measurements in ( ) are millimeters. - FOR UNDER THE CABINET - 30” = Knockout Holes “A” 36”, 42”, 48” = Knockout Holes “A” & “B” - FOR STAND ALONE (WITH OPTIONAL DUCT C...
Page 25 - PARTS LIST
23 PARTS LIST MODEL NO.: CH7930SQ, CH7936SQ CH7942SQ, CH7948SQ (Optional Duct Cover) NO. DESCRIPTION MODEL /SIZE PART NO. 1 Multi Duct Exhaust C1-0507-0301 2 Vent Cover (Top) B101-1530-12 3 Vent Cover (Rear) C1-0508-0311-A 4 Vent Cover Screw (1/8” x 3/8”) C1-0708-0003 5 Vent Cover Frame C1-0508-0311...
Page 28 - CIRCUIT DIAGRAM
Page 30 - DISCLAIMER; KOBE for the time limit.
28 DISCLAIMER 1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM. Upon acceptance of items, owner assumes responsibility for its safe arri...
Page 31 - WARRANTY; WARRANTY CERTIFICATE
29 WARRANTY WARRANTY CERTIFICATE KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement...
Page 32 - range hood or parts thereof to and from the dealer or Service Agent; CONSEQUENTIAL DAMAGE; MAY NOT APPLY TO YOU.; IMPLIED WARRANTIES/STATE LAW; from state to state.; SERVICE; For service contact:
30 3) The purchaser shall be responsible for any expenses involved in making the range hood readily accessible for servicing and where the range hood is installed outside the main sales territory of the retailer or service territory of the nearest approved KOBE Range Hoods Agent as applicable, for a...
Page 33 - PRODUCT REGISTRATION; Register Your Product!; section for complete warranty coverage information.; PLEASE MAIL IN YOUR WARRANTY REGISTRATION CARD AND PROOF OF; IMPORTANT: PLEASE KEEP A COPY OF YOUR SALE RECEIPT OR INVOICE HANDY
31 PRODUCT REGISTRATION Register Your Product! Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired or at our option the unit will be replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE ...