Page 2 - ertex; 2-Point Continuous Monitor; This avoids the requirement of scaling the value
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-8 If the concentration is non-zero and a fault exists, the concentration value will take priority and be reported. It is not possible to detect the existence of maintenance faults from the concentration outputs. Unlike previous Honey...
Page 3 - Word Address Hi Byte; HeartBeat
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-9 F.4 Data Map F i ve o f t h e o p t i o n a l f i e l d bu s s e s ( a l l ex c e p t LonWorks) report the status of the Vertex in the same 122 word (244 byte) format which is listed in Table F-5. If concentration information is no...
Page 5 - For more information about Profibus, see
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-11 F.5 Profibus Option (P/N 1295-0275) Profibus is a vendor-independent, open fieldbus s t a n d a r d fo r a w i d e ra n g e o f a p p l i c a t i o n s i n manufacturing and process automation. Vendor independence and openness are...
Page 6 - Procedure 1 - Changing Profibus Configuration
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-12 F.5.2 Profibus Module Configuration The Profibus interface is shipped from the factory with the address set to 3, the speed set to 19200 baud, and the memory length set to 122 words. The memory length to can be reduced to 41 words...
Page 7 - F.6 DeviceNet Interface; For more information about DeviceNet, see
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-13 F.6 DeviceNet Interface (P/N 1295-0329) The DeviceNet network is a low-level network that provides connections between simple industrial devices and higher-level devices (such as PLC controllers and computers). DeviceNet network u...
Page 8 - F.7 ControlNet Interface; Fo r m o r e i n fo r m a t i o n a b o u t C o n t r o l N e t , s e e
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-14 F.7 ControlNet Interface ControlNet a real-time, control-layer networ k providing for high-speed transpor t of both time-critical I/O data and messaging data, including upload/download of programming and configuration data and pee...
Page 9 - The pinout of the DF1 port is as follows:
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-15 F.8 DF1 Interface (P/N1295-0343) This module emulates the DF1 slave functionality of an Allen-Bradley SLC 5/03 DF1 port. It responds to queries for data from the N14 integer file by sending alarm, fault, and concentration data. Th...
Page 10 - F.9 Modbus Plus Interface; For more information on Modbus Plus, see
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-16 F.9 Modbus Plus Interface (P/N1295-0330) For more information on Modbus Plus, see http://eclipse.modicon.com . Technical information on the ProSoft Technology MVI46-MBP interface which is used in the Vertex can be found at http://...
Page 11 - F.10 LonWorks Interface; or; Table F-7: LonWorks Network Variable Outputs
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-17 F.10 LonWorks Interface (P/N 1295-0329) The LonWor ks protocol per mits peer-to-peer c o m m u n i c a t i o n w i t h o u t r e l y i n g o n a c e n t r a l controller. Routers permit expansion of networks to include thousands o...
Page 12 - An external personal computer with Microsoft
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-18 F.11 Modbus/TCP (P/N1295-0520) M o d b u s / T C P p r o v i d e s t h e h i g h l y r e l i a b l e communications like the other fieldbusses over fast, economical Ethernet media. This interface uses ProSoft-Technology MVI46-MNET...
Page 13 - Port; NETWORK MENU
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-19 Figure F-6 -- HyperTerminal Setup for Diagnostic Port Figure F-7 -- WATTCP.CFG File This procedure is used to set the IP Address Procedure 1 1. Determine the desired IP address, subnet mask, and default gateway. Usually a network ...
Page 15 - WARNING; heartbeat to increment as a complete loss of gas detection.; Table F-8: Data Presentation in Various PLCs
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-21 WARNING It is essential that Ethernet/CIP clients which communicate with the Vertex monitor the “Heart - beat” byte in word 40. This is because the MVI46-DFNT will continue to communicate if the Vertex PLC ceases to run. External ...
Page 17 - F.13 RSView32 Active Display; Rack; – The DAQ PC inside the Vertex rack.; Remote Station; – A computer external to the; Host ID Device; – A USB ethernet device with; Note
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-23 F.13 RSView32 Active Display Set-Up Instructions Three terms have special meanings in this section: Rack – The DAQ PC inside the Vertex rack. Remote Station – A computer external to the Vertex rack. The desktop computer will be us...
Page 18 - Add Rockwell Software to Rack
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-24 Ensure that all functionality is enabled by selecting Hardware, Optional from the Customized Windows Update as shown in Figure F-10. Figure F-10 Add Rockwell Software to Rack The RSView active display server is not installed on th...
Page 19 - . The splash screen is; Add Rockwell Software to Remote Computer
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-25 Active Display software is distributed via a CD labeled RSView32 and Active Display TM . For users on the Honeywell network, this software is available in the Rockwell Software folder at \\158.100.40.11\vtxinstl\ . The splash scre...
Page 20 - Add Honeywell Software to Remote Computer; CAUTION; Protect both the remote station and the net
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-26 When the setup program starts, click Client Install, highlighted in green in Figure F-13. Figure F-13 When the Rockwell software is properly installed on the remote client, the Windows control panel program list will include the f...
Page 21 - Add Rockwell License Files to the Rack
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-27 Add Rockwell License Files to the Rack (Master Disc Activation Method) Moving license files requires that all Rockwell applications be shut down, including RSLinx. To stop RSLinx, right-click the RSLinx icon (highlighted in green ...
Page 22 - Method 1
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-28 Add Rockwell License Files to the Rack (Factory Talk activation method) The Rockwell Factory Talk activation method consists of a host ID device that contains the license file locked to that particular host device’s MAC address an...
Page 23 - Method 2
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-29 rack computer (the description will be similar to “Realtek RTL8150 USB 10/100 Fast Ethernet Adapter #x”. Click Next. i. Verify the information on the confirm screen and click Next. j. On the following screen, note the file name an...
Page 24 - If the Vertex Rack does not currently use; sign above; Configure DCOM on Rack
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-30 If the Vertex Rack does not currently use Factory Talk Activation: The Factory Talk Activation Tool software must be installed on the Vertex rack and configured. A host device must also be purchased to host the license. The Factor...
Page 25 - DCOM Configuration
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-31 When OK is clicked, a Microsoft Component Services Management Console window, shown in Figure F-19, will appear. If a DCOM Configuration Warning! message appears (similar to the one in Figure F-18), close it by clicking Yes. Figur...
Page 26 - Other Settings on Rack
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-32 Figure F-22 Typical objects that might be added:• Administrators • ANONYMOUS LOGON • Everyone • Guests • INTERACTIVE • NETWORK • SYSTEM • Users Other Settings on Rack None. Other Settings on Desktop Windows’ firewall is incompatib...
Page 27 - Creating an Active Display Account; On the remote computer, navigate to; Figure F-25 Figure F-26
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-33 Add a new account as shown in Figure F-24 and add Honeywell Analytics to the Administrators group. Figure F-24 Create HMI account (optional) It is often useful to create multiple HMI accounts. This facilitates using the HMI securi...
Page 28 - Debugging; from the command prompt as shown in
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook F-34 Figure F-27 Click the Save user name and password (shown in Figure F-27) checkbox and then click OK. Figure F-28 Figure F-29 Debugging 1. Occasionally, a failed operation is manifestedby the desktop Active Display screen being all...
Page 30 - G Line Integrity Test
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook G-1 G Line Integrity Test Option
Page 31 - Pneumatic Overview
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook G-2 H o n ey we l l A n a l y t i c s n ow o f fe r s t h e o p t i o n a l capability to check for leaks in Vertex sample lines. Analyzers equipped with option 1295-0510 detect a pneumatic signal from valves installed at the end of th...
Page 32 - because of synchronization delays.; Quantitative Performance
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook G-3 Figure G-1 -- Simplified Pneumatic Schematic In practice, the sample pressure measurements are made as a differential measurement with the pump on and then off. This eliminates the effect of any transducer offset. However, since an...
Page 33 - Software Overview
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook G-4 The LIT measurement requires that the total pressure variance of the sampled point, the Vertex rack and the exhaust outlet must be less than 0.3 in. Hg. for correct operation (see Figure G-1). Software Overview Automatic LI tests c...
Page 34 - checkmark will be set.; LIT Access from RSView; RSView has two buttons.; Mode
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook G-5 checkmark will be set. LIT Access from RSView RSView has two buttons. 1. Two buttons in the Authorized Service screen as shown in Figure G-5. When the associated analyzer is in Monitor mode this will appear as shown in Figure G-6. ...
Page 35 - LIT Related Events; Maintenance Faults; Figure 4 -- Configuration Editor New Page
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook G-6 Pressing the “Record Known Good LITC” button will cause a characterization to be performed on all analyzers in the rack. Similarly, pressing the “Line Integrity Test” button will cause a line integrity test to be performed immediat...
Page 36 - H Warranty Statement
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook H-1 H Warranty Statement
Page 37 - Chemcassette
V ertex TM 72-Point Continuous Monitor Vertex Technical Handbook H-2 All products are designed and manufactured to the latest internationally recognized standards by Honeywell Analytics under a Quality Management System that is certified to ISO 9001. As such, this instrument (including the pump) is ...