Page 2 - VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES; Mechanical Installation; Mounting Plate Adjustment; IMPORTANT; Electrical Installation

VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES 62-0197—04 2 Fig. 3. Three-way ball valve flow orientation (not to scale). Fig. 4. Reset mixing control for discharge hot water. Fig. 5. Three-way mixing valve operation with coil bypass. Mechanical Installation The valveshave female NPT pipe fitting...

Page 3 - Valve assembly exploded view.; OPERATION AND CHECKOUT

VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES 3 62-0197—04 Fig. 6. Valve assembly exploded view. OPERATION AND CHECKOUT Once both the mechanical and electrical installations are complete: 1. Cycle the actuator to verify that the direction of rota- tion suits the control sequence. 2. If the rotat...

Page 4 - Automation and Control Solutions; Honeywell International Inc.

VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 http://customer.honeywell.com http://customer.honeywell.ca ® ...

1 Page 1
2 Page 2
3 Page 3
4 Page 4

Summary

Page 2 - VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES; Mechanical Installation; Mounting Plate Adjustment; IMPORTANT; Electrical Installation

VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES 62-0197—04 2 Fig. 3. Three-way ball valve flow orientation (not to scale). Fig. 4. Reset mixing control for discharge hot water. Fig. 5. Three-way mixing valve operation with coil bypass. Mechanical Installation The valveshave female NPT pipe fitting...

Page 3 - Valve assembly exploded view.; OPERATION AND CHECKOUT

VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES 3 62-0197—04 Fig. 6. Valve assembly exploded view. OPERATION AND CHECKOUT Once both the mechanical and electrical installations are complete: 1. Cycle the actuator to verify that the direction of rota- tion suits the control sequence. 2. If the rotat...

Page 4 - Automation and Control Solutions; Honeywell International Inc.

VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 http://customer.honeywell.com http://customer.honeywell.ca ® ...

Honeywell Manuals