Page 2 - UWP Mounting System installation; Drill holes at marked positions, and; Optional Decorative Cover Plate installation; Optional Cover Plate
2 UWP Mounting System installation 1. Open package to find the UWP. See Figure 1. 2. Position the UWP on the wall. Level and mark hole positions. See Figure 2. Drill holes at marked positions, and then lightly tap supplied wall anchors into wall using a hammer. ‒ Drill 7/32” holes for drywall. 3. Pu...
Page 3 - Terminal designations; Wiring UWP; Gently tug on the wires to
3 Terminal designations Conventional Systems Heat pump systems Terminal Description Terminal Description S/S Input for a wired indoor, outdoor sensor S/S Input for a wired indoor, outdoor sensor Y Compressor Stage 1 Y Compressor Stage 1 Y2 Compressor Stage 2 Y2 Compressor Stage 2 G Fan Relay G Fan R...
Page 4 - Setting Slider Tabs
4 Setting Slider Tabs Set R Slider Tab, see Figure 9. • Use built-in jumper (R Slider Tab) to differentiate between one or two transformer systems. • If there is only one R wire, and it is connected to the R , Rc , or RH terminal on the old thermostat, set the slider to the up position (1 wire) . • ...
Page 5 - Wiring; Conventional systems; Hot Water Relay Panel
5 Wiring 1H/1C System (1 transformer) R Power Rc [R+Rc joined by Slider Tab] Y Compressor contactor C 24VAC common W Heat relay G Fan relay NOTES: 1 Available wiring configurations differ by product models/product numbers.2 Use 18- to 22- gauge thermostat wire. Shielded cable is not required.3 Set t...
Page 6 - Heat pumps systems; H/1C Heat Pump System
6 Heat pumps systems 1H/1C Heat Pump System R Power Rc [R+Rc joined by Slider Tab] Y Compressor contactor C 24VAC common O/B Changeover valve G Fan relay 2H/1C Heat Pump System R Power Rc [R+Rc joined by Slider Tab] Y Compressor contactor C 24VAC common O/B Changeover valve G Fan relay Aux Auxiliary...
Page 7 - Ventilation systems; Mounting thermostat; Using U Slider Tab; Wired to ERV/HRV whole
7 Ventilation systems NOTE: Ventilation is not available on all models. Mounting thermostat 1 Push excess wire back into the wall opening. 2 Close the UWP door. It should remain closed without bulging. 3 Align the UWP with the thermostat, and push gently until the thermostat snaps in place. 4 If nee...
Page 8 - Installer setup – using the thermostat; Setup using the thermostat; START SETUP
8 Installer setup – using the thermostat Setup using the thermostat • After the Lyric thermostat has powered up, touch START SETUP on the thermostat. You’ll be asked if you want to perform setup via Lyric app. Touch No . • Touch or to toggle between Installer Set Up (ISU) options. • Touch Edit or to...
Page 9 - Advanced menu options; Installer setup – using the Lyric app; Setup using the Lyric app; Confirm; Lyric; Installer setup – advanced menu; enu
9 Advanced menu options Device Setup This is used to access the device ISU setting. Screen Lock The thermostat touch screen can be set to lock fully or partially. Rater View A read only place to view all the ventilation settings. System Test Test the heating and cooling system. Range Stop (Temperatu...
Page 10 - Key features; Menu button for 5
10 Auto Chg. On AM Heat On Menu Fan Mode Fan Auto Mode Heat Wake Away Home Sleep Following Schedule Recovery Key features The screen will wake up by pressing the center area of the displayed temperature. The screen will stay lit for 45 seconds. Brightness can be adjusted in the Menu. System status i...
Page 11 - Installer setup options (ISU) – advanced menu; ot; ISU options av
11 Installer setup options (ISU) – advanced menu # IS U IS U N am e IS U O p ti on s (d ef au lt s in b ol d ) N ote s 120 Sc he du le Ty pe No S ch ed ule M O -S U = E ve ry d ay t he s am e M O -F R, S A, S U = 5 -1 -1 s ch ed ul e M O -F R , S A -S U = 5 -2 sc h ed u le Ea ch D ay = E ve ry d ay ...
Page 12 - Installer setup options (ISU)– advanced menu
12 Installer setup options (ISU)– advanced menu # IS U IS U N am e IS U O p ti on s (d ef au lt s in b ol d ) N ote s 25 6 EM H ea t T yp e E le ct ri c, Ga s/ Oi l ( or F os sil F or ce d A ir) Th is I SU i s d isp la ye d o nl y i f I SU 2 00 i s s et t o H ea t P um p A ND i f I SU 2 21 A ux /E h...
Page 17 - Performing a system test; Viewing equipment status
17 Performing a system test You can test the system setup in ADVANCED MENU under SYSTEM TEST option. 1 Press and hold Menu on the Lyric thermostat for 5 seconds to access ADVANCED MENU options. 2 Touch or to go to SYSTEM TEST . 3 Touch Select or touch text area. 4 Touch or to select system test type...
Page 18 - Troubleshooting; Number Alert/Reminder; Alerts and reminders
18 Screen is blank • Check circuit breaker and reset if necessary. • Make sure power switch at heating and cooling system is on. • Make sure furnace door is closed securely. Screen is difficult to read • Change screen brightness in thermostat Menu . Increase brightness intensity for inactive backlig...
Page 20 - Home and Building Technologies; Specifications
Home and Building Technologies In the U.S.:Honeywell1985 Douglas Drive NorthGolden Valley, MN 55422-3992http://customer.honeywell.com ® U.S. Registered Trademark.© 2017 Honey well International Inc.33-0 0153—09 M.S. Rev. 08-17Printed in U.S. A . CAUTION: MERCURY NOTICE If this product is replacing a...