Page 2 - Description of Diaphragm Seals; Figure 2
34-ST-03-57 Page 2 Description of Diaphragm Seals Diaphragm seals are traditionally used when a standard pressure transmitter should not be exposed to the process pressure directly. Diaphragm seals typically protect the pressure transmitter from one or more damaging aspects of the process media. Con...
Page 4 - Configuration Toolkit provides an easy way to
34-ST-03-57 Page 4 Figure 12 - Welded Meter Body for All-Welded Remote Seal Solution. The welded ST 3000 meter body is an important part of an All-Welded Remote Seal Solution, which is commonly used in Vacuum applications. Figure 12 Description Features The ST 3000 transmitter can replace any 4 to 2...
Page 5 - Page 5; Specifications; Operating Conditions – All Models; See Figure 13
34-ST-03-57 Page 5 Specifications Operating Conditions – All Models Parameter Reference Condition (at zero static) Rated Condition Operative Limits Transportation and Storage °C °F °C °F °C °F °C °F Ambient Temperature 25 ±1 77 ±2 -25 to 70 -13 to 158 -40 to 85 -40 to 185 -55 to 125 -67 to 257 Proce...
Page 6 - CTFE
34-ST-03-57 Page 6 1Atm Special High Vacuum Construction required. Consult STC. 9000 8000 7000 600050004000 3000 2000 1000 Maximum Pressure Limited by Flange Rating of Seal 10000 900 800 700 600 500400 300 200 100 90 80 70 60504030 20 10 Pressure (mmHgA) -40 5 25 30 0 100 175 350 450 200 300 400 500...
Page 7 - Page 7; —Supply voltage and loop resistance chart; Parameter; For F; Fieldbus use
34-ST-03-57 Page 7 Note: A minimum of 250 ohms of loop resistance is necessary to support communications. Loop resistance equals barrier resistance plus wire resistance plus receiver resistance. = Operating Area 0 10.8 16.28 20.63 25 28.3 37.0 42.4 1440 1200 800 650 450 250 Operating Voltage (Vdc) L...
Page 8 - (Reference – Includes; Maximum capillary length and diaphragm size chart.; Performance Under Rated Conditions - General for all Models; Fieldbus and HART protocols.
34-ST-03-57 Page 8 Performance Under Rated Conditions * - Models STR94G (0 to 500 psi/35 bar) Parameter Description Upper Range Limit psi bar 500 35 Minimum Span psi bar 20 1.4 Turndown Ratio 25 to 1 Zero Elevation and Suppression No limit except minimum span from absolute 0 (zero) to +100% URL. Acc...
Page 9 - Page 9; Physical and Approval Bodies; ATEX
34-ST-03-57 Page 9 Physical and Approval Bodies Parameter Description Process Interface See Model Selection Guide for Material Options for desired Seal Type. Seal Barrier Diaphragm 316L Stainless Steel, Monel, Hastelloy C, Tantalum Seal Gasket Materials Klinger C-4401 (non-asbestos) Grafoil Teflon G...
Page 11 - Application Data; Liquid Level: Closed Tank; ¥ Transmitter above datum
34-ST-03-57 Page 11 Application Data Liquid Level: Closed Tank Determine the minimum and maximum pressure differentials to be measured (Figure 17). PMin = (SGp x a) - (SGf x d) = LRV when HP at bottom of tank = –URV when LP at bottom of tank PMax = (SGp x b) - (SGf x d) = URV when HP at bottom of ta...
Page 12 - Density or Interface; LP; fill fluid (See Page 9 for
34-ST-03-57 Page 12 Density or Interface Calculate the minimum and maximum pressure differentials to be measured (Figure 18). Pmin = (SGmin – SGf) x (d); minimum density, 4mA output Pmax = (SGmax – SGf) x (d); maximum density, 20mA output Where: d = distance between the taps SGmax = maximum Specific...
Page 13 - Reference; millimeters; STR93D DP/I Remote Seal with Horizontal Pipe Mount
34-ST-03-57 Page 13 Reference Dimensions: millimeters Inches STR93D DP/I Remote Seal with Horizontal Pipe Mount STR94G LGP/I Remote Seal with Horizontal Pipe Mount 24272 Seal omitted for clarity with meter Optional external ground 45.7 1.8 53.1 2.09 Removal Clearance for All Caps 82.9 3.26 With Smar...
Page 14 - STR93D DP/I Remote Seal with Vertical Pipe Mount
34-ST-03-57 Page 14 Reference Dimensions: millimeters Inches Sealomitted forclarity Optionalexternalground with meter 45.7 1.8 53.12.09 RemovalClearancefor All Caps 82.93.26 W ithSmart meter W ithout meter 94.93.74 65.12.56 W ithout meter 23.5.925 STR93D DP/I Remote Seal with Vertical Pipe Mount Opt...
Page 15 - Mounting Bracket; Fieldbus
34-ST-03-57 Page 15 Options Ordering Information Mounting Bracket The angle-mounting bracket is available in either zinc-plated carbon steel or stainless steel and is suitable for horizontal or vertical mounting on a two-inch (50 millimeter) pipe, as well as wall mounting. An optional flat mounting ...
Page 16 - Instructions; XXXX; Dual Head DP
34-ST-03-57 Page 16 Model Selection Guide (34-ST-16-34) Instructions • Select the desired Key Number. The arrow to the right marks the selection available. • Make one selection from each table, I and II, using the column below the proper arrow. • S elect as many Table III options as desired (if no o...
Page 17 - Selection
34-ST-03-57 Page 17 TABLE II - SEALS Format for Seal Selection: Specify 12 characters _ _ _ _ _ _ _ _ _ _ _ _ Availability Common Required Seal STR9xx Note: The first 3 characters are common to all seals.When selecting required seal, you must specify 3D 4G only the 9 selections within the required s...
Page 23 - - with M20 Conduit Connections; Meter Body Options
34-ST-03-57 Page 23 STR9xx TABLE III - OPTIONS Selection 3D 4G None 00 • • Communication Options HART 5.x Protocol Compatible Electronics HC e e H6 e e FOUNDATION Fieldbus Communications FF r r Indicating Meter Options Analog Meter (0-100 Even 0-10 Square Root) ME • • Smart Meter SM • • Custom Confi...
Page 27 - Dimensions and drawings
34-ST-03-57 Page 27 Dimensions and drawings Figure 20a. Flush Flanged Seal Figure 20b. Flush Flanged Seal 20a 20b20b20a20a20a 20a 20b20b20a20a20a 20a 20b20b20a20a20a 20a 20b20b20a20a20a Figure 21a. Flush Flanged Seal Figure 21b. Flush Flanged Seal 21a 21b21b21a21a21a 21a 21b21b21a21a21a 21a 21b21b21...
Page 32 - HART* is a trademark of the Hart Communication Foundation.; Honeywell International Inc.
34-ST-03-57 Page 32 ST 3000 ® is a registered trademark of Honeywell International Inc. FOUNDATION ™ is a trademark of the Fieldbus Foundation. HART* is a trademark of the Hart Communication Foundation. Honeywell Process Solutions Industrial Measurement and Control Honeywell International Inc. 2500 ...