34-ST-03-57 Page 2 Description of Diaphragm Seals Diaphragm seals are traditionally used when a standard pressure transmitter should not be exposed to the process pressure directly. Diaphragm seals typically protect the pressure transmitter from one or more damaging aspects of the process media. Con...

Page 4 - Configuration Toolkit provides an easy way to

34-ST-03-57 Page 4 Figure 12 - Welded Meter Body for All-Welded Remote Seal Solution. The welded ST 3000 meter body is an important part of an All-Welded Remote Seal Solution, which is commonly used in Vacuum applications. Figure 12 Description Features The ST 3000 transmitter can replace any 4 to 2...

Page 5 - Page 5; Specifications; Operating Conditions – All Models; See Figure 13

34-ST-03-57 Page 5 Specifications Operating Conditions – All Models Parameter Reference Condition (at zero static) Rated Condition Operative Limits Transportation and Storage °C °F °C °F °C °F °C °F Ambient Temperature 25 ±1 77 ±2 -25 to 70 -13 to 158 -40 to 85 -40 to 185 -55 to 125 -67 to 257 Proce...