Page 3 - Perfect Window Fresh Air Ventilation Systems; Read and save these instructions.
Perfect Window Fresh Air Ventilation Systems NEED HELP? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. Read and save these instructions. ® U.S. Registered Trademark. Patents pending. Copyright © 2009 Honeywell ...
Page 4 - Safety Definitions and Precautions; Safety Definitions; These safety terms identify information you must read.; Safety Precautions; Electrical shock hazard.
GETTING ST AR TED Safety Definitions and Precautions Safety Definitions These safety terms identify information you must read. CAUTION: Indicates a hazardous situation which, if not avoided, could cause bodily injury or property damage. WARNING: Indicates a hazardous situation which, if not avoided,...
Page 5 - Features
GETTING ST ARTED The HR150B and HR200B Perfect Window™ Fresh Air Ventilation Systems provide proper levels of ventilation with energy savings by transferring heat between the exhaust and fresh air streams. The ER150B and ER200B Perfect Window™ Fresh Air Ventilation Systems provide proper levels of v...
Page 6 - Heat Recovery Ventilator; Planning the Installation
GETTING ST AR TED The Fresh Air Ventilation System is designed to supply fresh air and exhaust stale air. The system draws fresh outdoor air through the ventilator for distribution throughout the house. Heat Recovery Ventilator Stale air is exhausted through the ventilator and to the outdoors. Heat ...
Page 7 - Sizing
GETTING ST ARTED Sizing ASHRAE 62.2 There are several methods that can provide satisfactory results for sizing a ventilator to provide adequate ventilation for a home. There is a new residential ventilation standard, ASHRAE 62.2, that suggests the following: 7.5 CFM per person (count people as 1 per...
Page 8 - Mounting Position and Location; Locate fresh air intake 6 ft (2m) or more from stale; Ducting; Sealing insulated duct terminations.
GETTING ST AR TED Mounting Position and Location The HR150/ER150 and HR200/ER200 can be suspended from exposed ceiling joists, ceiling surface or floor mounted. (Level ventilator so drains function correctly.) NOTE: ER150C and ER200C are specifically designed for installations in unconditioned space...
Page 9 - Keep duct sizes as large as possible throughout the installation.
GETTING ST ARTED Design and installation of ductwork must be according to standard HVAC practice to deliver required quantities of fresh air to temperature-controlled space and exhaust equivalent quantities of room air to the outside. Keep intake and exhaust duct runs as short as possible with few b...
Page 11 - Balancing Airflow; Dehumidistat; the defrost timer is activated. At the end of the
GETTING ST ARTED Balancing Airflow Balancing the airflow verifies that the Fresh Air Ventilation System is delivering the intended airflow and energy performance. Use the Airflow Balancing instructions in the Installation section to check and balance the airflow. Controls Remote Override Switch Func...
Page 12 - MOUNTING; When Installing this Product...; Fresh Air Ventilation System.; Mounting; INSTALLATION
MOUNTING When Installing this Product… 1. Read these instructions carefully. Failure to follow these instructions could damage the product or cause a hazardous condition.2. Check the ratings on the product to make sure the product is suitable for your application.3. Installer must be a trained, expe...
Page 13 - PLUMBING; Installing Drain Line and P-Trap; Installing drain line.
PLUMBING Installing Drain Line and P-Trap M6552 DRAIN PAN O RING HR BOTTOM WASHER NUT Installing drain line. Fig. 8. There are two holes at the bottom of the ventilator for the drain pan connectors. Insert the connectors through the hole in the drain pan 1. and the bottom of the unit.Place the washe...
Page 14 - WIRING; Digital Fan Timer; Digital fan timer lights and Select Button.
WIRING WIRING CAUTION: Electrical shock hazard. Can cause personal injury.Be sure ventilator is correctly grounded. Confirm polarity of power line switched with safety (disconnect) switch when cleaning or servicing unit. IMPORTANT The hot line (black) is the correct line to switch. See Fig. 19. To c...
Page 15 - Wiring digital fan timer.
WIRING 1 2 3 4 5 6 7 8 9 10 VNT LOW RED YEL GRN VNT HI G F R G T DSTAT M29844 JUMPER BETWEEN VNT COM AND RED. CHOOSE AMONG AVAILABLE CONTROLS. ALL WIRE IDENTICALLY. 1 1 2 2 VISIONPRO IAQ VNT1, 2 TERMINALS Off 10 20 30 40 50 60 W8150 AUX TERMINALS CONTROL OPTIONS MECHANICAL TIMER DRY CONTACTS TRUE IA...
Page 16 - Wiring for fan interlock.
WIRING 1 2 3 4 5 6 7 8 9 10 VNT LOW VNT COMRED YEL GRN VNT HI G F R G T DSTAT M29848 JUMPER BETWEEN VNT COM AND RED. JUMPER BETWEEN DHM2 AND VNT1. 1 1 2 2 DHM 1 DHM 2 VNT 1 VNT 2 VisionPRO IAQ 20 40 60 TIMER FA N INTERLOC K 1 2 3 4 5 6 7 8 9 10 VNT LOW VNT COMRED YEL GRN VNT HI G F R G T DSTAT M2984...
Page 17 - Internal schematic for fresh air ventilation systems.
WIRING LEGEND HIGH VOLTAGE12V LOW VOLTAGE M29742 K7 K2 K3 P2 RED THERMISTOR (NOT ON ALL UNITS) BLACK GREEN NEUTRAL LINE AUTO- TRANSFORMER SEE DEFROST DETAIL WHITE P4 BLUE K4 K6 K1 P3 FAN O/P T8 T7 P1 T3 T2 T9 T1 K5 DIRECT MOUNTED CAPACITOR CAPACITOR DEFROST DETAILS PCB PLUG-IN PLUG IN CONNECTOR BLAC...
Page 18 - DUCTING; Airflow Balancing; Excessive positive pressure; Balancing Procedure
DUCTING Airflow Balancing Volume-balanced airflow in the ventilator is required. Volume of outside air brought in must equal the volume of air the unit exhausts. If airflow is not correctly balanced: unit does not operate at its maximum efficiency. • negative or positive air pressure can occur in th...
Page 19 - APPENDICES; LED on Terminal Board of Ventilator; STARTUP AND CHECKOUT; Cleaning Filters and Core
APPENDICES When the ventilator is powered up it will go through a self-test and turn on both fan speeds and check damper operation. LED on Terminal Board of Ventilator The terminal board has an LED that flashes to indicate the current mode of the ventilator. Ventilator Mode Flashing Sequence Descrip...
Page 20 - TROUBLESHOOTING
APPENDICES Table 1. Troubleshooting Guide. Symptom Cause Solution Poor airflow Plugged outside hood 1/4 in. (6 mm) mesh. • Clean exterior hoods or vents • Filters plugged. • Remove and clean filter. • Core obstructed. • Remove and clean core. • House grilles closed or blocked. • Check and open grill...
Page 22 - PARTS LIST; Part Number for; Accessory Items Parts List Not Shown—All Models; Part Number; Fresh Air Ventilation Control
APPENDICES PARTS LIST HR/ER Parts List Item Number (Fig. 21) Part Number for Description HR150B/HR200B ER150B/ER200B ER150C/ER200C 1 209746 Heat Transfer Core, Aluminum with Plastic Frame 32002074-001 32002074-001 Cross-Flow Energy Transfer Core, with Guide Channels, diamond shape made before August...
Page 24 - TRADELINE® Models; Specifications
APPENDICES IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit might not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in per...
Page 28 - Automation and Control Solutions
Automation and Control Solutions Honeywell International Inc.1985 Douglas Drive NorthGolden Valley, MN 55422 Honeywell Limited–Honeywell Limitée35 Dynamic DriveToronto, Ontario M1V 4Z9http://yourhome.honeywell.com ® U.S. Registered Trademark© 2010 Honeywell International Inc.68-0171—12 M.S. Rev. 02-...