Page 2 - Disclaimer; © 2006 - 2012 Honeywell International Inc. All rights reserved.; Trademarks; Stratos; Patents; For patent information, please refer t
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this pub...
Page 3 - NTRODUCTION
ii T ABLE OF C ONTENTS I NTRODUCTION Manual Scope ........................................................................................................................................................................................ 1 Product Overview .................................................
Page 6 - Figure 1. Model Number Designation; xxx; D e s c r i p t i o n; Applicable for IBM
2 I NTRODUCTION M ODEL N UMBER D ESIGNATION M O D E L N U M B E R D E S I G N AT I O N Figure 1. Model Number Designation B ASE K IT C OMPONENTS B AS E K I T C O M P O N E N T S P a r t # D e s c r i p t i o n MS2 3 2 1 * / MS2 3 2 2 * Stratos H Series Scanner * See model number designation above fo...
Page 7 - E P L AC E M E N T
3 I NTRODUCTION O P T I O N AL A C C E S S O R I E S P a r t # D e s c r i p t i o n AC to DC Power Transformer - Regulated Output: +5V @ 4A +12V @ 1.5A 46-46812 120V United States and Canada 46-46813 220V – 240V Continental European 46-46814 220V – 240V United Kingdom 46-46817 220V – 240V China 46-...
Page 8 - Figure 5
4 I NTRODUCTION G ENERAL P RECAUTIONS The following list includes general precautions to remember when handling the Stratos H . D O N OT T URN the unit upside down with the platter in place. D O N OT P RESS on the window in the placement platter or the vertical window frame. P LATTER R EMOVAL No har...
Page 9 - For Regulatory Compliance Information refer to pages 46 - 48.; Environmental; Specifications are subject to change without notice.
5 I NTRODUCTION MS2321 / MS2322 S CANNER D ESIGN S PECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <2.2 mW Embedded Laser: Max Optical Power: 10 mW Wavelength: 650 nm Horizontal Depth of Field: 0 mm - 152 mm (0"- 6") for 0.33 mm (13 mil) Bar Code...
Page 10 - Components
6 B ASE M ODEL C HARACTERISTICS MS2321 Scanner Components Figure 6. MS2321 Components Components I TEM N O . D ESCRIPTION OF I TEM 1 Blue and White LED Indicators (see page 30) 2 Volume/Tone Multi-Function Button (see page 35) 3 Diamonex or Sapphire Horizontal Window (Laser Aperture) 4 Flow Directio...
Page 11 - Dimensions; Custom Scale
7 B ASE M ODEL C HARACTERISTICS MS2321 Scanner Dimensions Figure 7. MS2321 Dimensions Connector Panel Figure 8. MS2321 Connector Panel Scale ready MS2321 models supply additional connectors for scale and display communication cabling. The use of these connections is dependent on the specific manufac...
Page 12 - Caution and Serial Number Labels
8 B ASE M ODEL C HARACTERISTICS MS2321 Scanner Caution and Serial Number Labels Figure 9. MS2321 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage)...
Page 15 - Caution
11 B ASE M ODEL C HARACTERISTICS MS2322 Scanner Caution and Serial Number Labels Figure 13. MS2322 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltag...
Page 16 - SWAP
12 I NSTALLATION Q UICK I NSTALLATION O UTLINE The following is a quick preview of the steps required for first time installations. Each item is discussed in detail later in this section. • Determine clearance, ventilation and service access requirements. • Determine checkout counter layout taking i...
Page 18 - MS2321 Mounting Diagram (Two Point Support); Figure 18. MS2321 Mounting Diagram, Two Point Support
14 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER MS2321 Mounting Diagram (Two Point Support) Figure 18. MS2321 Mounting Diagram, Two Point Support Specifications are subject to change without notice.
Page 19 - MS2321 Mounting Diagram (Three Point Support); Figure 19. MS2321 Mounting Diagram, Three Point Support
15 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER MS2321 Mounting Diagram (Three Point Support) Figure 19. MS2321 Mounting Diagram, Three Point Support Specifications are subject to change without notice.
Page 20 - MS2322 Mounting Diagram (Two Point Support); Figure 20. MS2322 Mounting Diagram, Two Point Support
16 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER MS2322 Mounting Diagram (Two Point Support) Figure 20. MS2322 Mounting Diagram, Two Point Support
Page 21 - MS2322 Mounting Diagram (Three Point Support); Figure 21. MS2322 Mounting Diagram, Three Point Support
17 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER MS2322 Mounting Diagram (Three Point Support) Figure 21. MS2322 Mounting Diagram, Three Point Support Specifications are subject to change without notice.
Page 22 - Recall Defaults
18 I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) RS232 The following steps describe how to properly install the cables for an RS232 Stratos H application. The scanner must then be configured to match the host’s RS232 parameters. Cable installation alone does not guarantee that the Strat...
Page 24 - USB; Scanner USB to Host; IBM OEM Full Speed USB Communication Defaults**
20 I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) F ULL S PEED USB The following steps describe how to properly install the cables for a Full Speed USB Stratos H application. The scanner must then be configured to match the host’s USB parameters. Cable installation alone does not guarant...
Page 25 - MetroSelect Configuration Guide (
21 I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) F ULL S PEED USB Step 8 is for USB Serial Emulation Mode or Keyboard Emulation Mode only. 8. Configure the Stratos H for Bi-Directional USB Serial Emulation Mode or USB Keyboard Emulation Mode by scanning the appropriate configuration bar...
Page 26 - DC Power In; Generation Communication Defaults and IBM 3; Generation Protocols.
22 I NSTALLATION C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) RS485 The following steps describe how to properly install the cables for an RS485 Stratos H application. The scanner must then be configured to match the host’s RS485 parameters. Cable installation alone does not guarantee that the Strat...
Page 30 - EAS; Base Model; EAS In; Figure 27. EAS Deactivation Area
26 I NSTALLATION EAS D EACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is a list of Checkpoint recommended switch bank settings. Base Model Checkpoint Recommended Switch Bank Settings MS2321 SW1 & SW2 switches 1 and 6 set t...
Page 34 - ON
30 Figure 33. LEDs S CANNER O PERATION I NDICATOR D ESCRIPTIONS Audible When in operation the Stratos H provides audible feedback that indicates the status of the unit and the current scan. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone) plus three vol...
Page 36 - Diagnostic Indicator Display; Figure 34. Error Code Display
32 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under the platter near the end of the scanner farthest from the vertical window (see figure below). Figure 34. Error Code Display The following is a list of possible error cod...
Page 38 - Blink Power Save Mode:; Laser Off
34 S CANNER O PERATION P OWER S AVE M ODES The Stratos H has five configurable power save modes. Refer to the MetroSelect Configuration Guide ( PN 00-02407 x ) for additional information on Power Save Modes. 1. Blink Power Save Mode: Blinks the laser OFF & ON after a configured period of non-use...
Page 39 - Figure 35. The Multi-Function Volume Button; Power Save Mode; Waking the Unit from All Power Save Modes; Figure 36. Changing the Beeper Volume
35 S CANNER O PERATION B EEPER O PTIONS AND B UTTON F UNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the following bar code. The new tone will be heard followed by a short pause. Two more new tones will be heard signifying the new setting has been stored in memo...
Page 40 - Default Settings
36 S CANNER O PERATION S TARTUP When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep once ( the white LED will remain on for the duration of the beep ). The scanner is now ready to scan. P OWER -U P T EST M ODE When a Stratos H scanner i...
Page 42 - Figure 40. Vertical Scan Window Replacement
38 M AINTENANCE V ERTICAL S CAN W INDOW R EPLACEMENT ( PN 46-46889) Figure 40. Vertical Scan Window Replacement D AILY M AINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the horizontal and vertical output windows will need occasional cleaning. For the glas...
Page 46 - Figure 41. Connector Layout on the Bottom of the Scanner; Scanner to Host, RS485; Specifications are subject to change without notice
42 S CANNER AND C ABLE T ERMINATIONS S CANNER P INOUT C ONNECTIONS The Stratos H scanner terminates to 10-pin modular jacks located on the bottom of the unit. The serial number label indicates the model number and interface of the scanner. EAS Auxiliary RS232 In Pin Function Pin Function 1 EAS In 1 ...
Page 47 - reference only; Scale; Figure 42. Scale Ready Connector Layout; Scale Display Data In; Scale Data to Display; Scale Data In; RS232 from the Load Cell; Scale to Display; Pin
43 S CANNER AND C ABLE T ERMINATIONS S CALE R EADY MS2321 M ODELS – A DDITIONAL P INOUT C ONNECTIONS There are four additional 10-pin modular jacks located on the bottom of the of the MS2321 Stratos H models that may be used for an integrated scale application and the use of a remote display. When u...
Page 48 - No Connect
44 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS The following cables are examples of some of the standard cables that may be shipped with the Stratos H scanner. Please keep in mind that every application is unique and the cables received with the Stratos H may be custom cables...
Page 49 - 0-Position Angled Modular Plug
45 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS Aux Port Configuration Cable*, PN 57-57008 x -N-3 Pin Function ** 9-Pin D-Type Connector 1 No Connect 2 Output from Scanner 3 Input to Scanner 4 No Connect 5 Ground 6-9 No Connect RS232 LSO/AUX Cable PN 57-57099 x -3 or PN 57-570...
Page 51 - EMC
47 R EGULATORY C OMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Note : Immunity performance is not guaranteed for scanner cables greater than 3 meters in length when fully extended. Changes or modifications not expressly approved by the party responsibl...
Page 52 - Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist
48 R EGULATORY C OMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully ex...
Page 56 - Technical Support Portal:
52 C USTOMER S UPPORT T ECHNICAL A SSISTANCE If you need assistance installing or troubleshooting your device, please contact us by using one of the methods below: Knowledge Base:
Page 60 - Honeywell Scanning & Mobility
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02270 Rev G 8/12