Honeywell MKXXII - Manuals
Honeywell MKXXII – Manual in PDF format online.
Manuals:
Manual Honeywell MKXXII
Summary
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 2 This document is an unpublished work. Copyright 2000 Honeywell, International, Inc. All rights reserved. This document and all information and expression contained herein are the pr...
Honeywell MK VI MK VIII EGPWS Installation Design Guide Proprietary notice on title page applies CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 5 TABLE OF CONTENTS SECTION I – GENERAL INFORMATION....................................................................................
Honeywell MK VI MK VIII EGPWS Installation Design Guide Proprietary notice on title page applies CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 9 3.3.14.1 Instructions .......................................................................................................... ....
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 12 SECTION I GENERAL INFORMATION
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 14 SECTION I – GENERAL INFORMATION SECTION I – GENERAL INFORMATION............................................................................................ 16 1.1 I NTRODUCTION ........
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 16 SECTION I – GENERAL INFORMATION 1.1 Introduction The Honeywell MK XXII Enhanced Ground Proximity Warning System (MK XXII EGPW S) provides alerts and warnings to prevent controlled fl...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 17 1.4 Reference Documents Following is a list of Honeywell reference documents: 965-1590-601 Product Specification for the MK XXII Enhanced Ground Proximity Warning System (EGPWS) 993-...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 18 1.5 Description of Equipm e nt The MK XXII EGPW S is a rack mount ground proximity warning (GPW S) and terrain display (TAWS) computer. Some of the system features include: ♦ Basic H...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 19 1.5.1 MK XXII EGPWS Comp u ter The MK XXII EGPW S computer is available under P/N 965-1590-0XX with internal GPS. The MK XXII EGPW S computer is intended for Helicopters and provides...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 20 aircraft that do not have another compatible source of outside air temperature. Outside Air Temperature is used by the EGPW S along with pressure altitude in computing Geometric Alti...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 21 FIGURE 1-1 MK XXII EGPWS SMART CABLE 1.6 Technical Characteris t ics MK XXII EGPWS TSO Compliance: TSO-C92c, TSO-C151a, class A Physical size (HxWxD): 6.20” x 3.04” x 10.30” Weight: ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 22 Physical size: 2.68” x 1.51” x 0.32” (fits Positronic connector backshell) Weight: <1 pound with connector and backshell Mounting: Mounts to Positronic connector backshell Tempera...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 24 1.8 Installation and Acces s ories Kits NOTE: Not all installation kits are immediately available, contact Honeywell Order Administration (425-885-8719) for availability. 1.8.1 MK XX...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 25 1.8.4 Terrain Database Card s The MK XII EGPWS Terrain Database Cards can be ordered using the following part numbers: Vendor Name Vendor P/N Description QTY UM Honeywell P/N Honeywe...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 28 1.11 Tools Required 1.11.1 Crimping Tool - P1, P 2 , P3 Description UM QTY Vendor Name & Part Number Hand Crimping Tool EA 1 Positronic Ind. 9507 Hand Crimping Tool EA 1 Daniels ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 30 SECTION II INSTALLATION
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 32 SECTION II – INSTALLATION SECTION II - INSTALLATION .............................................................................................................................. 33 ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 33 SECTION II - INSTALLATION 2.1 Introduction This section contains suggestions and factors to consider before installing the Enhanced Ground Proximity Warning System. Close adherence t...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 34 2.3.2 MK XXII Computer Loc a tion Care should be exercised to avoid mounting components near equipment operating with high pulse current or high power outputs such as radar and satel...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 35 E. Slide the EGPW S unit in the mounting tray, and secure it using the Hold Down latch. F. (After Continuity and Power check) Attach the cable harness to the front panel connectors a...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 36 D. Position Slide Lock and Spring Clip onto connector. E. Install Backshell Housing onto connector. The Ground wire (used for ESD discharge) is terminated with shielded pigtails insi...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 37 INSTALLATION ASSEMBLY SEQUENCE STEP 1 Install all MK XXII system aircraft wiring to this connector using items 1.2 (Crimp Contacts) and item 1.1 (Connector). See figure 2-1.1 below. ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 38 STEP 2 Wire item 2.0 (Configuration Module). This part will replace item 1.4 (Backshell plate). Install the pre-crimped colored wires into item 1.1 (Connector) as shown in figure 2-1...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 40 STEP 4 Install item 1.3 (Backshell Housing) onto connector using item 1.8 (Screws) as shown in figure 2-1.4 below: Ground Wire (used for electrostatic discharge {ESD} protection) is ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 46 2.3.10.2 Location Cockpit layout, size and operator’s preference will determine if only one set of lights is used (i.e., mounted in the center), or if dual sets of lights are used (o...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 47 FIGURE 2-1.8 MK XXII EGPWS Annunciators/Switches Location
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 48 2.3.10.3 Inhibit Switch Functio n s and Selection The Terrain Inhibit and Audio Inhibit functions are optional but it is recommended that one be used to inhibit the system during cer...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 49 FIGURE 2-2 MK XXII EGPWS OUTLINE
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 50 FIGURE 2-3 MK XXII EGPWS MOUNTING TRAY Honeywell P/N 405-0383-001
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 52 SECTION III SYSTEM PLANNING
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 54 SECTION III – SYSTEM PLANNING SECTION III – SYSTEM PLANNING.................................................................. 57 3.1 I NTRODUCTION ......................................
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 57 SECTION III – SYSTEM PLANNING 3.1 Introduction This section provides information for selecting features and wiring the electrical interfaces of the MK XXII EGPW S. Sample wiring diag...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 58 3.2.3 GPS Antenna A GPS antenna connector is available on the front of the MK XXII EGPWS 965-1590-0XX. 3.2.4 Analog and Digital Inp u ts The analog and digital inputs to the MK XXII ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 59 3.2.7 Audio Output The audio outputs consist of both an 8-ohm amplifier and a transformer isolated 600-ohm output. Audio output messages are provided as specified in the selected Aud...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 60 3.3 Configurable Interface s The following subsections define configurable interfaces for the EGPW S. Typical interface connection information and diagrams are provided. Use this in ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 61 not detect autorotation and thus do not provide the autorotation altitude callouts or advanced gear warnings. Mode 1 is inhibited in these types. The generic types are segregated int...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 62 3.3.2.2 Examples 3.3.2.3 Analog altitude and 500 ohm OAT 62 43 9 25 63 44 53 J1 Altitude Out Signal Common BIT Out Analog Air Data Computer EGPW S MK XXII (+) (-) Uncorrected Baromet...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 63 3.3.2.4 Digital – ARINC 429 (Cat. 2 ID 5, 1, 6) Air Data Type 1 (AZ-800 or equivalent) is a low speed, digital ARINC 429 signal having the air data labels 203, 206, 212, and 213. Air...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 65 3.3.2.6 Shadin 2000 (Cat. 2 ID 10) Air Data Type 10 (Shadin 2000 or equivalent) is a low speed, digital ARINC 429 signal having the air data labels 203, 204, 206, and 212. Total Air ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 67 3.3.3 Category 3 – Position Input Select Category 3 defines the Global Position System bus type and interface. GPS Input selection is available in the following formats: ARINC 429 lo...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 68 3.3.3.Examples 3.3.3.1 ARINC 429 BUS (Cat. 3 ID 0,1,4,5) 25 8 A B J2 ARINC 429 GPS ARINC 429 Bus - Hi ARINC 429 Bus - Lo EGPW S MK XXII A B ARINC 429 GPS Bus ARINC429-GPS.vsd 429 GPS...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 70 3.3.4 Category 4 – Altitude Callouts Category 4 defines the Altitude Callout menu choices and Smart ‘500’ Callout selection along with Autorotation callout enablement. Appendix E Tab...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 71 3.3.5 Category 5 – Audio Menu Select Category 5 defines one Audio Menu options for Helicopters (ID 128). 3.3.5.1 Instructions 1. Using Appendix E Tables E 3, Under Step/category 5 se...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 72 3.3.6 Category 6 – Terrain Display Select Category 6 defines the Terrain Display options available. Appendix E Table E 3.1.6 defines the Terrain Display Select options ( Display Conf...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 73 3.3.6.3 Terrain Display Configuration Group This option provides the ability to specify the type of Terrain Display compatible with the aircraft configuration. A definition of each o...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 74 W X System R/ T J2-37 J2-36 J1-58 J1-59 J1-51 J1-32 A B A B ARI NC 453 T E RRAI N BUS #1 ARI NC 429 RANG E BUS J1-54 T e rrain Display Select #1 Discret e O u tput T e rrain Pop-Up D...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 75 3.3.6.4 Display Input Control Group This input bus is connected to the display (or display controller) and transmits Range settings, Display Mode, and Display status to the MK XXII E...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 76 Honeywell Gr im es TRA-45A J2 J1 J1 J1 28 13 1 3 28 13 1 3 37 36 41 40 58 59 56 57 TE RR INHIB TE RR INOP Lam p Tes t 28V Lam p Di m m ing B u s A lternate A c ti on 12 55 EGPW S TRA...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 77 Honeywell GNS- XLS J2 J1 J101 J101 N5 N6 Q4 Q6 N5 N6 Q4 Q6 37 36 25 8 41 40 58 59 56 57 TE RR INHIB TE RR INOP Lam p Tes t 28V Lam p Di m m ing B u s A lternate A c ti on 12 55 EGPW ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 78 AVIDYNE FSD J2 J1 J5 J5 17 35 4 22 17 35 4 22 37 36 41 40 58 59 56 57 TE RR INHIB TE RR INOP Lam p Tes t 28V Lam p Di m m ing B u s A lternate A c ti on 12 55 EGPW S AVIDYNE FSD AVID...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 79 Integr ated Pr im us 440/660/880 J2 J1 F G M L 37 36 41 40 58 59 56 57 TE RR INHIB TE RR INOP Lam p Tes t 28V Lam p Di m m ing B u s A lternate A c ti on 12 55 EGPW S Honeywell Radar...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 80 AVTECH DSU Primus WXR UDI J2 J1 J1 8 9 47 48 37 36 41 40 58 59 56 57 TE RR INHIB TE RR INOP Lam p Tes t 28V Lam p Di m m ing B u s A lternate A c ti on 12 55 EGPW S AVTECH DSU A B AR...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 81 3.3.7 Category 7 – Options Select Group #1 Category 7 enables/disables the following Options: Steep Approach (not available in MkXXII), TA&D Alternate Pop Up, Peaks Mode, Obstacl...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 82 For Helicopters TA&D Alternate Pop Up should always be set to False. 3.3.7.4 Peaks Mode Peaks mode is an alternate means of displaying terrain data. The standard terrain display ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 83 3.3.7.8 WOW Reversal The WOW discrete input is defined in Category 13. The Category 7 control is used to reverse the defined logic to match aircraft wiring, if necessary. +28 VDC WOW...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 84 3.3.8 Category 8 – Radio Altitude Input Select Category 8 defines the Radio Altitude and Decision Height interface. 3.3.8.1 Instructions 1. Using Appendix E Tables E 3, under Step/ca...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 86 3.3.9 Category 9 – Navigation Inputs Select Category 9 selects the Glideslope and Localizer Deviation interfaces and Glideslope Validity and ILS Tuned discretes. Appendix E Table E 3...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 87 3.3.9.2 Example 3.3.9.3 Analog Glideslope Interface (cat. 9 ID 0,1,5) J2 ILS Receiver EGPWS MK XXII GS Valid +28 11 + - Low Level GS Valid +28 GND ILS Tuned + - GS Deviation 65 46 30...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 88 3.3.9.4 Digital Glideslope/Localizer Interface 22 5 J2 ILS Bus A B EGPWS MK VI / MK VIII A B ARINC 429 ILS ARINC 429Low Speed Vendor Model ARINC 429 Bus 1 ARINC 429 Bus 2 A B A B Hon...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 89 3.3.10 Category 10 – Attitude Input Select Category 10 defines the Roll and Pitch Attitude interface. 3.3.10.1 Attitude Signals Roll Angle is used for Bank Angle callout, Pseudo Alti...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 90 3.3.10.3 Example 3.3.10.4 Analog Roll Angle (Synchro) 576 1 21 2 J1 Vertical Gyro X Y EGPWS MK XXII Roll Angle Z X Y Roll Synchro Z X Y Pitch Synchro Z X Y Z Pitch Angle Vendor Model...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 91 3.3.10.5 Digital ARINC 429 High Speed Attitude Input ID 128 (Litef LCR 92S or equivalent) is a high speed, digital ARINC 429 signal having roll pitch angle, and roll pitch rate label...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 92 3.3.11 Category 11 – Heading Input Select Category 11 defines the Magnetic Heading interface. Appendix E Table E 3.1.11 defines the Heading Input Select types and identifies the firs...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 93 3.3.11.3 Example 3.3.11.3.1 Analog Heading (Synchro) (CAT. 11 ID 0) 22 23 3 J1 Directional Gyro X Y EGPW S MK XXII X Y Heading Synchro Heading Z Z H C 4 24 26 VAC Reference H C Headi...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 95 3.3.12 Category 12 – Windshear Input Select Category 12 defines the Windshear interface. Windshear is not applicable to MK XXII. 3.3.12.1 Instruction Select ID 0 for all helicopter c...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 96 3.3.13 Category 13 – Input / Output Discrete Type Select Category 13 defines the input and output discretes not defined as part of any of the other Categories. Appendix E Table E 3.1...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 100 3.3.13.12 Timed Audio Inhibit Discrete The Timed Audio Inhibit will cause the inhibiting of all audio messages for a period of 5 minutes or until reset. The discrete input is connec...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 101 For Lamp Format Type 1, the amber “Below G/S” lamp is driven by the GPW S Alert (Glideslope only) discrete and the red “GPW S” lamp is driven by the remaining alerts and warnings. F...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 102 3.3.13.22 Terrain Display Select #1 & #2 Discrete Terrain Display Select #1 & #2 discrete (J1-54 & J1-49) will activate after the related pilot has initiated manual sele...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 103 Table 0-1 MKXXII EGPWS – Example Cockpit Lights
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 104 3.3.14 Category 14 – Audio Output Level Category 14 controls the Audio Output level for alert menu callouts (cautions and warnings). Refer to Category 13 for information on the Mode...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 105 3.3.15 Category 15, Autorotation Threshold Category 15 controls the Autorotation Threshold level used for Autorotation detection. Actual thresholds are determined during first of ty...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 106 AUTOROTATION THRESHOLD Aircraft Type ID Aircraft Model Threshold % Threshold ID 128 S-76 B/C+ 7.5 15 129 S-76C/A++ 7.5 15 130 S-76A/A+ 7.5 15 131 Bell 212 6 12 131 Bell 412 6 12 132...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 107 SECTION IV CONFIGURATION MODULE PROGRAMMING AND REGIONAL TERRAIN DATABASE LOADING
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 108 SECTION IV – CONFIGURATION MODULE PROGRAMMING AND REGIONAL TERRAIN DATABASE LOADING SECTION IV – CONFIGURATION MODULE PROGRAMMING AND REGIONAL TERRAIN DATABASE LOADING .................
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 109 SECTION IV – CONFIGURATION MODULE PROGRAMMING AND REGIONAL TERRAIN DATABASE LOADING 4.1 Introduction The following procedures outline the steps necessary to accomplish a complete con...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 110 parameters, for testing purposes, without altering its operation. The monitoring of these parameter values enables the operator to quickly determine if the EGPW C is using the correc...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 111 To obtain a copy of the WinVIEWS software, contact: Honeywell Aerospace Electronic Systems PO Box 97001 Redmond, W A 98073-9701 USA Attn: Order Administration M/S 33 Phone: (425) 885...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 112 - CUW<space>0 is the command and version number. CUW writes the category ID’s defined by version 0 definition (0 is the only version currently available) to the Configuration M...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 114 Category 7 ID: 29 Category 8 ID: 1 Category 9 ID: 0 Category 10 ID: 2 Category 11 ID: 0 Category 12 ID: 0 Category 13 ID: 129 Category 14 ID: 0 Category 15 ID: 15 CRC: 527518533 4.5....
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 115 associated ID is read from the Configuration Module and listed on the PC display. Alternately, when not in the Configuration sub-mode, the command “PS<Enter>” (Present Status) ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 117 4.6.5 Accomplishment Instr u ctions Load the PCMCIA card data as described in paragraphs 4.6.5 A. or 4.6.5 B. below. Loading time will be approximately 70 minutes. A. Loading the PCM...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 118 (3) Connect the Smart Cable (Honeywell PN 951-0386-001) to the EGPW C J3 connector. (4) Turn the Power Supply ON and verify the COMPUTER OK LED on front of the EGPWC panel is on. (5)...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE:97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 119 to continue from level-to-level, the ST button must also be ‘pressed and held’ for more than 0.5 seconds, but less than 2 seconds, which is identical to the Short Cancel function. Th...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 121 SECTION V CERTIFICATION
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 124 SECTION V – CERTIFICATION 5.1 Introduction This section outlines the procedures required to obtain FAA approval for the MK XXII EGPW S installation. 5.2 Certification Procedur e 5.2...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 127 APPENDIX A CUSTOMER WORKSHEET
MK XX II E GPWS ENH A N CED GROUND PROXIMITY W A R N ING SYSTEM CAG E CO DE: 97896 SCALE: NO NE SIZE: A D W G NO : 06 0-431 4-22 5 R EV: C SHEET 12 8 T he pur pos e f o r th is w o rk s heet is to obt ai n th e nec es s a ry a ir c ra ft data f o r det er m ining th e s pec if ic inter fa c e c onf ...
MK XX II E GPWS ENH A N CED GROUND PROXIMITY W A R N ING SYSTEM CAG E CO DE: 97896 SCALE: NO NE SIZE: A D W G NO : 06 0-431 4-22 5 R EV: C SHEET 13 0 DISCRETE INPUTS: Ple as e c hec k appl ic ab le box es f o r both up an d do wn pos it ions . PA RA M E T E R G N D O PEN +28 VDC DH > ° > ° WO ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 139 APPENDIX B SAMPLE WIRING DIAGRAMS
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 143 APPENDIX C WinViews OPERATION INSTRUCTIONS
Honeywell MK XXII Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 145 APPENDIX C – WinViews Operation Instructions RS-232 COMMUNICATION WITH THE EGPWS The EGPW S contains software that allows monitoring of its internal parameters, for testing purposes, with...
Honeywell MK XXII Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 146 WinVIEWS OPERATION: Windows Virtual Interface to the Enhanced Warning System WinVIEWS software is a tool developed by Honeywell to monitor or view values within the EGPW S. The WinVIEW S ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 149 APPENDIX D VENDOR DRAWINGS
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 151 D 1-0 Vendor Contact Information The vendor contact information provided below is current at the time of publication of this document. AMP 2800 Fulling Mill RoadMS 038-035Middletown...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 153 D1-1 EDMO EDMO Distributors (800)235-3300 – “One Stop Shopping” for the following EGPWSand TAWS support products: * MD41-12XX/13XX TAWS ACU’s from Mid-Continent Instruments * 90-448...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 154 D1-2 EMTEQ EMTEQ, Inc. supports all EGPW S/TAWS systems manufactured by Honeywell, Inc. by offering products to help complete your installation. The installation provisions are full...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 155 TABLE 1 Table 1.A. (Teflon ® Jacketed RF Coax) (High Temp) Cable Type Loss @ 1600 Mhz O.D. Bend Radius P/N Per 100 ft (inches) Minimum TFLX130-100 21.60 dB 0.130 “ ½” TFLX165-100 17...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 156 TABLE 2 Table 2.A.1 Connectors (for TFLX cable series) - GPS GPS Connector Type Application Description TFLX130-100 TFLX165-100 TFLX205-100 TNC male Antenna Straight TMS130-1 TMS165...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 158 Tool Frame and Die Part Numbers Mil-Spec P/N Daniels Cable Type for Hex Die P/N for Hex Die Tool Frame Die Hex PFLX195 M22520/5-19 Y142 M22520/5-01 (HX4) B Hex PFLX200 M22520/5-19 Y...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 159 Installation Considerations: Meeting the specifications when faced with a long cable run could be challenging at some times. Solutions typically are found when combining a Low Loss ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 160 D1-3 Aerospace Optics Aerospace Optics Inc. Aerospace Optics Inc. is pleased to support the Honeywell EGPWS/TAWS teamwith our line of Vivisun LED lighted switches and indicators. We...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 162 D1-4 StacoSwitch StacoSwitch As a supplier of high reliability switches and indicators for avionics since 1958,StacoSwitch is proud to be integrated with many Honeywell products and...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 163 APPENDIX E INTERFACE DESCRIPTION DOCUMENT
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 166 INTRODUCTION E 1 PART NUMBER This document is the Interface Description for the MKXXII Helicopter Enhanced Ground Proximity Warning System(EGPWS) part number 965-1590-0XX. The MK XX...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 168 3 Note that this is not a floating input. +28 VDC must be applied to both PWR_H and +28 VDC Return to both PWR_L inputs. E 4.2.3 DC ANALOG INPUTS Unless otherwise specified, Input S...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 169 When used as a validity input:Active Voltage Range (Logic True) +160 to +840 mVDC Inactive Voltage Range (Logic False) 0 to 50 mVDC Broken Wire Detect Input will be biased less than...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 170 E 4.2.7 AC ANALOG INPUTS Unless otherwise specified, Input Signal accuracy is1% linearity +0.1% full scale offset E 4.2.7.1 SYNCHRO ROLL ATTITUDE Quantity 1 Input Impedance: X leg &...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 171 E 4.2.7.3 CONFIGURATION DEFINED SYNCHRO INPUTS Quantity 3 Input Impedance: X leg > 140 K Ω Input Impedance: Y leg > 140 K Ω Input Impedance: Z leg > 140 K Ω Maximum Reverse...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 174 E 4.2.9.4 AIR DATA RS-232 DIGITAL SERIAL BUS (SERIAL PORT 2) One port is provided for use with Air Data computer or Static Pressure Sensor interfaces. This port is common with the A...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 175 The Ground discretes are internally biased via a pull up resistor, and are externally pulled down to ground when active. Thecharacteristics of each Ground discrete input are as foll...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 176 E 4.2.13 OAT VOLTAGE REFERENCE OUTPUT This output is an accurate voltage source for 500 Ω resistive temperature sensors. Quantity 1 Output Voltage 5.000 VDC ± 10 mVDC (no load) Nomi...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 177 • If a ‘soft’ Glideslope alert is being issued (given 6 dB below nominal alert volume level). • If a Self Test is in progress, alerts are given 6 dB below nominal alert volume level...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 178 E 4.2.17.2 ARINC 453 OUTPUT BUS Quantity 2 Format 1600 bit Manchester BI-phase per ARINC 708A Data Rate 1 Mb per second Word/Frame Structure Refer to Section 7.2 Data definition Ref...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 179 E 4.2.18.2 PCMCIA / SMARTCABLE PORT One port is provided which meets the Motorola SPI characteristics. The PCMCIA / SmartCable interface allows for both theuploading, and downloadin...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 180 E 5 AIRCRAFT APPLICATION DATA This section describes the MK XXII EGPWS interfaces for aircraft applications. Section E 5.1 is a listing of the selectioncategories defining the vario...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 181 TABLE E 3 CATEGORY ID SELECTION PROCEDURE Step (Category) Signal Selection Instruction Ident No . 1 Selects: a) AircraftType b) Mode Type Using Table 5.3.1, and any sub-tablescontai...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 182 Step (Category) Signal Selection Instruction Ident No . 9 Selects: a) Glideslopeand/orLocalizerSource Using Table 5.3.9, and any sub-tablescontained within, locate the desiredNaviga...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 184 TABLE E 3.1.1: HELICOPTER TYPE ID AND TORQUE INPUTS FOR EGPWS MK XXII ID Torque Type DESCRIPTION Effectivity Table (E 3.1.1-x) App. Cfg. 128 0 Helo, S-76B/C+, Retractable Gear -003 ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 185 E 5.3.1.2 ENGINE TORQUE DATA SELECTION WHEN A SINGLE ENGINE HELICOPTER IS ADDED TO THIS SECTION, IT NEEDS TO BE TREATED AS IF THERE WERE TWO ENGINES VIA AIRCRAFT WIRING. THE SRD REQ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 189 E 5.3.2 CATEGORY 2, AIR DATA INPUT SELECT The following table provides identification of the Air Data source type. The entry in the Air Data Type corresponds to atable that provides...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 190 TABLE E 3.1.2-0: AIR DATA INPUT SELECT #0 SIGNAL CONNECTION SUMMARY DATA Uncorrected BarometricAltitude (+) = J1-62(-) = J1-43 Format: DC with Validity FlagInput Type: BasicFault De...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 195 TABLE E 3.1.2-12: AIR DATA INPUT SELECT #12 SIGNAL CONNECTION SUMMARY DATA Uncorrected BarometricAltitude (+) = J1-62(-) = J1-43 Format: DC with Validity FlagInput Type: BasicFault ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 196 MSL type. The Universal GPS1000 based GPS sources are of WGS-84 type. If the internal GPS source (ID=2) is defined,the GPS altitude reference in Category 7 must be MSL. Note 2: Univ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 197 TABLE E 3.1.3-2: POSITION INPUT TYPE 2 (INTERNAL RS-232 GPS) CHANNEL GPS_RXA GPS_TXA Internal GPS [XPGPS_Int] = 1 (9600 baud) Fault Designation: INTERNAL GPSBus Type: Basic Internal...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 198 TABLE E 3.1.3-5: POSITION INPUT TYPE 5 (HIGH SPEED ARINC 743 GPS) CHANNEL 429RX_4 CONNECT TO: GPS (High Speed) per ARINC 743 Fault Designation: GPS BUSBus Type: Basic A = J2-25 B = ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 199 E 5.3.4 CATEGORY 4, ALTITUDE CALLOUTS The following table provides identification of the Altitude Callouts Menu. Each entry in the ID column corresponds to aparticular menu selectio...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 201 E 5.3.5 CATEGORY 5, AUDIO MENU SELECT The following table provides identification of the Voice Menu type. Each entry in the Voice Menu column has acorresponding table that provides ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 202 E 5.3.6 CATEGORY 6, TERRAIN DISPLAY SELECT Section Overview The following table (5.3.6) has an identification number (ID) associated with each Terrain Display configuration. Each of...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 204 Table E 3.1.6-0 KC Picture Bus DISPLAY CONFIGURATION GROUP 0 (KC PICTURE BUS 2 ) Function Value Display Type KC Picture Bus (KCPB) Sweep Type Curtain (Vertical or Horizontal scan) C...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 217 Table E 3.1.6-16 Bendix IN182A/IN812A Radar display (RDR 2000) Function Value Reference section Display Type Bendix IN182A/IN812A color Radar Display (RDR-2000 radarsystem) Sweep Ty...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 218 Output 429 Bus Group 0 Channel Pins Comments 429TX_1 (Low Speed) A = J2-43B = J2-42 Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, 7.1.4.x, and7.1.6.x 1 429TX_2 A = J2...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 221 Table E 3.1.6-18 K C P ictu re B u s w /o p resen tation of T errain A w aren ess C orrected A ltitu d e Function Value Reference section Display Type KC Picture Bus (KCPB) Sweep Ty...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 223 Table E 3.1.6-235 Display Configuration (Collins ProLine II, 5x6, and ProLine 4) Function Value Reference section Display Type Collins ProLine II (5x6) Sweep Type Standard with +/-6...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 224 Table E3.1.6-236 Display Configuration (Collins ProLine IV, 5x6) Function Value Display Type Collins ProLine IV (5x6) Sweep Type Standard with +/-60 degree limit Category 7, Options...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 226 Table E 3.1.6-242 KC Picture Bus Display Configuration Group 0 (KC Picture Bus 1 ) Function Value Display Type KC Picture Bus (KCPB) Sweep Type Curtain (Vertical or Horizontal scan)...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 229 • If the display is in normal MFD mode (not HSI backup, or SG backup) AND if Label 051 bit 11 transitions from 0to 1 (rising edge), AND Checklist is not selected on the MFD, and TCA...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 230 Table E 3.1.6-255 Honeywell SPZ8000 (w/ SCI range) Display Configuration Group 255 (Honeywell SPZ8000 older style) Function Value Display Type Honeywell (5x6) (SPZ8000) older style;...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 231 E 5.3.7 CATEGORY 7, OPTIONS 1 SELECT The following table provides identification of the Options Select Group #1. Each entry in the ID column corresponds to aparticular combination o...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 233 E 5.3.8 CATEGORY 8, RADIO ALTITUDE INPUT SELECT The following table provides identification of the Radio Altitude type. The entry in the Radio Altitude Type corresponds to atable th...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 236 E 5.3.9 CATEGORY 9, NAVIGATION INPUT SELECT The following table provides identification of the Navigation type. The entry in the Navigation Type corresponds to a tablethat provides ...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 237 TABLE E 3.1.9-1: NAVIGATION INPUTS SELECT 1 SIGNAL CONNECTION SUMMARY DATA Glideslope Deviation (+) = J1-65(-) = J1-46 Format: ARINC 547 with Low Level Validity & ILS SelectInpu...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 238 E 5.3.10 CATEGORY 10, ATTITUDE INPUT SELECT The following table provides identification of the Roll Attitude Angle type. The entry in the Attitude Input Selectcorresponds to a table...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 240 E 5.3.11 CATEGORY 11, HEADING INPUT SELECT The following table provides identification of the Heading type. The entry in the Heading Input Select corresponds to a tablethat provides...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 241 E 5.3.12 CATEGORY 12, WINDSHEAR INPUT SELECT The Windshear warning is not applicable to Helicopters. The following table provides the definition of Windshear Input Select ID 0, whic...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 242 E 5.3.13 CATEGORY 13, INPUT / OUTPUT DISCRETE TYPE SELECT The following table provides identification of the Input/Output Discrete Type. Each entry in the Input/Output Discrete Type...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 243 TABLE E 3.1.13-128: INPUT/OUTPUT DISCRETE TYPE 128 CONN PIN # CHANNEL DESIGNATION REFERENCE PIN TYPE PIN FUNCTION Polarity/Configuration J1-38 28V_DISC_02 Input +28V Glideslope Inhi...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 245 E 5.3.14 CATEGORY 14, AUDIO OUTPUT LEVEL The following table provides identification of the Audio Output Level Select. Each entry in the ID column corresponds to aparticular nominal...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 246 E 5.3.15 CATEGORY 15, AUTOROTATION THRESHOLD The following table provides identification of the Autorotation Threshold. Each entry in the ID column corresponds to anengine torque th...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 247 E 6 CONNECTOR INTERFACE E 6.1 PINOUT FOR FRONT CONNECTORS SORTED BY PIN NUMBER TABLE E 4: PIN ASSIGNMENT FOR FRONT CONNECTORS SORTED BY PIN NUMBER Connector - Pin Channel Designatio...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 249 Connector - Pin Channel Designation Reference Signal Usage Summary* J2-26 429TX_2A EGPWS ARINC 429 Output #2 (A leg) J2-27 422_232TX_2A ADC RS-232 / 422 Output (A leg) J2-28 GND GPS...
Honeywell MK XXII EGPWS Installation Manual CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C SHEET 252 E 7 DEFINITIONS The following acronyms are provided for use with this document: Acronym Interpretation AAAS Alternate Audio Alert Select ADC Air Data Computer ADS Air Data System AG...
Honeywell Manuals
-
Honeywell DT8050A
Installation Manual
-
Honeywell DT8050A
Manual
-
Honeywell DT8050A
User Manual
-
Honeywell DT8050
Manual
-
Honeywell DT8050
User Manual
-
Honeywell TPFIT25WK
User Manual
-
Honeywell TPFIT25AWK
User Manual
-
Honeywell TPFIT32WK
User Manual
-
Honeywell TPFIT32AWK
User Manual
-
Honeywell 24DX47
User Manual
-
Honeywell 24DX47
Manual
-
Honeywell TPFIT50PWK
User Manual
-
Honeywell TPFIT50WK
User Manual
-
Honeywell TPFIT50AWK
User Manual
-
Honeywell TPFIT50APWK
User Manual
-
Honeywell 00010
User Manual
-
Honeywell ADVBLEWIFI
Manual
-
Honeywell ADVBLEWIFI
User Manual
-
Honeywell ADVBLE
Manual
-
Honeywell ADVBLE
User Manual