Page 3 - ii; ABLE OF
ii T ABLE OF C ONTENTS Introduction................................................................................................ 1 Scanner and Accessories.......................................................................... 2 Operational Notes ...................................................
Page 4 - iii
iii T ABLE OF C ONTENTS Installing the Optional Wall/Counter Mount ............................................. 21 Troubleshooting Guide ............................................................................ 22 RS-232 Demonstration Program ........................................................
Page 5 - Ruby with Verifone, RS232
1 I NTRODUCTION Orbit ® is an aggressive, omnidirectional laser bar code scanner. Lightweight and rugged, Orbit is small in size, but BIG in performance. Designed for applications where counter space is limited, Orbit is theideal presentation scanner for retail, convenience, liquor and specialtystor...
Page 6 - Standard
2 S CANNER AND A CCESSORIES B ASIC K IT Part # Description MS7120 Orbit ® Presentation Laser Scanner 00-02407 MetroSelect ® Programming Guide 00-02408 MS7120 Installation and User’s Guide* * Available on the Metrologic website - www.metrologic.com O PTIONAL A CCESSORIES Part # Description AC to DC P...
Page 7 - MX009 USB Converter Cable; PERATIONAL; enter the program mode and select the appropriate bar codes.
3 S CANNER AND A CCESSORIES O PTIONAL A CCESSORIES Part # Description MVC** Metrologic Voltage Converter Cable+12VDC to +5.2VDC or -12VDC to +5.2VDC MX009-2** MX009 USB Converter Cable ** Contact a Metrologic customer service representative for additional information on the MVC and MX009 cable serie...
Page 9 - Manufacturer’s Recommendation:
5 I NSTALLATION FOR K EYBOARD W EDGE I NTERFACE 1. Turn off the PC/Host. 2. Connect the male 10-pin RJ45 end of the PowerLink cable to the jack onthe MS7120. 3. Connect the L-shaped plug of the power supply into the power jack onthe PowerLink cable. 4. Make sure the AC input requirements of the powe...
Page 11 - USB; Please refer to the; installation and programming guidelines.; Enable Laser Emulation Mode
7 I NSTALLATION N OTES FOR USB I NTERFACE Metrologic’s MX009 USB cable is a device that converts serial RS232formatted data to either USB Keyboard or USB Point-of Salecommunication protocol. Please refer to the MX009 USB Converter Cable Programming Guide ( MLPN 00-02574A) supplied with your MX009 ca...
Page 13 - One Beep; first; Razzberry Tone
9 A UDIBLE I NDICATORS When the MS7120 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings areavailable for the tone of the beep (normal, 6 alternate tones and no tone).To change the tone, refer to the MetroSelect ® Programming Guide...
Page 17 - Optimal High Density; Scan Area
13 S CAN V OLUME S PECIFICATIONS Specifications based on 100% UPC Bar Codes. Optimal Low Density (Default) Optimal High Density 190mm 60mm 100mm Scan Area 215mm 105mm Scan Area 60mm
Page 18 - Close
14 S CAN V OLUME S PECIFICATIONS (C ONT .) Specifications based on 100% UPC Bar Codes. Close Normal 95mm 175mm Scan Area 60mm Scan Area 190mm 60mm 100mm
Page 19 - Far
15 S CAN V OLUME S PECIFICATIONS (C ONT .) Specifications based on 100% UPC Bar Codes. Far 215mm Scan Area 75mm 75mm 105mm
Page 20 - Minimum Bar Code Element Width
16 D EPTH OF F IELD BY M INIMUM B AR C ODE E LEMENT W IDTH Optimal Low Density (Default) Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width A B C D E F G H J K mm .13 .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5.2 5.7 6.3 6.8 7.5 9 10 13 21 26 0 00 0 0 0 B ...
Page 23 - Normal
19 D EPTH OF F IELD BY M INIMUM B AR C ODE E LEMENT W IDTH Normal Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width A B C D E F G H J K mm .13 .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5.2 5.7 6.3 6.8 7.5 9 10 13 21 26 0 0 00 D & &
Page 26 - All Interfaces; MS7120 Series Troubleshooting Guide; SYMPTOMS; RAM or ROM failure
22 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to preserve thelimited warranty terms on page 39. All Interfaces MS7120 Series Troubleshooting Guide SYMPTOMS POSSIBLE CAUSE(S) SOLUTION No LEDs, beep...
Page 27 - Enable beeper. Select tone
23 T ROUBLESHOOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit powersup, but doesnot scan and/orbeep Beeper disabled. Notone selected Enable beeper. Select tone The unit powersup, but doesnot scan and/orbeep Scanning a particularsymbology that is notenabled UPC/EAN, Code 39, i...
Page 29 - Keyboard Wedge Only
25 T ROUBLESHOOTING G UIDE (C ONTINUED ) Keyboard Wedge Only SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit scansthe bar codebut there is nodata Configuration is notcorrect Make sure the scanner isconfigured for the appropriatemode. Check internal jumper The unit scansbut the data isnot correct Config...
Page 30 - Programming Guide
26 T ROUBLESHOOTING G UIDE ( CONTINUED ) RS-232 Only SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Power-up OKand scans OKbut does notcommunicateproperly to thehost Com port at the host isnot working orconfigured properly Check to make sure that thebaud rate and parity of thescanner and the communicationport ...
Page 32 - CANNER; Keyboard
28 A PPLICATIONS AND P ROTOCOLS The model number on each scanner includes the scanner number andfactory default communications protocol. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S ) 7120 00 Laser EmulationRS-232 Transmit/Receive 7120 9 OCIA and RS-232 Transmit/Receive(Full RS232 Conf...
Page 33 - with; Continued next page
29 D ESIGN S PECIFICATIONS MS7120 S PECIFICATIONS O PERATIONAL Light Source: VLD 640-660 nm Depth of Field: 0 mm to 216 mm (0" to 8.5") for 0.33 mm (13 mil) bar codes Scan Speed: 1067 scans/second Scan Pattern: 5 fields of 4 parallel lines (omnidirectional) Scan Lines: 20 Min Bar Width: 0.13...
Page 34 - Specifications subject to change without notice.
30 D ESIGN S PECIFICATIONS MS7120 S PECIFICATIONS E LECTRICAL Input Voltage: 5.2VDC ± 0.25V Power: 1.0 W typical Operating Current: 200 mA typical, 250 mA typical for IBM models DC Transformers: Class II; 5.2VDC@ 650 mA Laser Class: CDRH: Class IIa; EN 60825-1:1994/A11:1996 Class 1 EMC: FCC, ICES-00...
Page 40 - Scanner Pinout Connections; Options listed are program/cable selections
36 1 10 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections The MS7120 scanner interfaces terminateto a 10-pin modular jack. The serial # labelindicates the interface enabled when thescanner is shipped from the factory. Someunits have internal jumpers that can be movedto enable a different ...
Page 41 - Cable Connector configurations; PowerLink Cable; Stand Alone Keyboard Cable
37 S CANNER AND C ABLE T ERMINATIONS MS7120-11 IBM 46XX/RS-232 Pin Function 1 Ground 2 RS-232 Transmit Output 3 RS-232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 IBM 46XX transmit 8 IBM 46XX Receive 9 +5VDC 10 Shield Ground Options listed are program/cable selections Cable Connector config...
Page 42 - Cable Connector Configuration
38 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configuration The PowerLink cable is terminated with a 5-pin DIN female connector onone end, and a 6-pin mini DIN male on the other. Metrologic will supply an adapter cable with a 5-pin DIN male connectoron one end and a 6-pin mini DIN female conn...
Page 43 - USA Corporate Headquarters
39 L IMITED W ARRANTY The MS7120 Orbit © scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS7120 scanners have a two (2) year limited warranty from the date ofmanufacture. Metrologic warrants and represents that all MS7120 scanners are free of alldefects in ...
Page 44 - OTICES; Reorient or relocate the receiving antenna.
40 N OTICES Notices This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates, use...
Page 45 - The following notice applies to Model number MS7120-11 only.; Ferrite Choke Installation:; Figure 1
41 N OTICES Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungenoder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kundesollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten.Sehen Sie niemals in den Laserstrahl, selbst wenn Sie ...
Page 46 - Figura 1
42 N OTICES Die nachfolgende Mitteilung gilt nur für Modell Nr. MS7120-11 Zur Klassifizierung gemäß Klasse B nach FCC Teil 15, ICES-003 und EN55022,befestigen Sie den vorliegenden Ferritkern an dem mitgelieferte PowerLinkKabel Ihres MS7120-11 Barcode Scanners. Ferritkern Installation: 1. Entfernen S...
Page 47 - Instalación del obturador de ferrita
43 N OTICES Nota (exclusivamente para los modelos de la serie MS7120-11) De acuerdo con las normativas FCC apartado 15, ICES-003 y EN55022 para laClase B, el obturador de ferrita del PowerLink que se suministra con el modelode lector de códigos de barras MS7120-11. Instalación del obturador de ferri...
Page 49 - NDEX
45 I NDEX A accessories .......................... 2, 3adapter....................... 2, 3, 5, 38application.............................. 27audible ..................................... 9authorized service center....... 11autodiscriminates ................... 29 B bar code .......... 1, 3, 8-10, 12...
Page 52 - Printed in USA