Page 3 - Installation Precautions; Adherence to the following will aid in
Installation Precautions Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of powercan be connected to the fire alarm controlpanel. Disconnect all sources of power before servicing. Control unit and associated equipmentma...
Page 4 - Documentation Feedback
Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions aboutour printed manuals you can email us. Please include the following information: Product name and version number (if applicable) Manual part number and revisi...
Page 5 - TABLE OF CONTENTS
IFS-2600 Installation & Programming Manual Page 1 P/N 10069 ECN08-0066 TABLE OF CONTENTS COMPATIBLE DETECTORS................................................................................................ 5 OVERVIEW ..................................................................................
Page 9 - COMPATIBLE DETECTORS
IFS-2600 Installation & Programming Manual Page 5 P/N 10069 ECN08-0066 COMPATIBLE DETECTORS Make Model Type Model Number System Sensor Thermal Type A 5451 AUS System Sensor Thermal Type A 51A51 System Sensor Thermal Type B 4451 AUS System Sensor Thermal Type B 51B51 System Sensor Thermal Type B ...
Page 10 - OVERVIEW; CAUTION
Page 6 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 OVERVIEW IFS-2600 Fire Indicator Panel (FIP) is designed to provide simplicity to the end user. The FIP uses both a liquid crystaldisplay and conventional LED displays for fast and accurate display of system status and changi...
Page 11 - SPECIFICATION; APPROVALS
IFS-2600 Installation & Programming Manual Page 7 P/N 10069 ECN08-0066 SPECIFICATION Cabinet Zinc Sealed Steel 1.6mm Powder Coated Hinged Inner Door Hinged Outer Door Outside Dimensions 2608 (8 zones) 394mm H x 390mm W x 180mm D* 2624 (24 zones) 750mm H x 390mm W x 180mm D* 2600 (32 to 64 zones)...
Page 12 - Additional relay outputs:
Page 8 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 SYSTEM EXPANSION Zones Qty Hardware Required Product Code 8 1 Main Control Board PCB-2004 1 Main Termination board PCB-2005 1 Power Supply board PCB-2006 16 1 Main Control board PCB-2004 1 Main Termination board PCB-2005 1 Po...
Page 13 - POWER SUPPLY RATINGS AND SETTINGS; Internal 5VDC 2A Power Supply
IFS-2600 Installation & Programming Manual Page 9 P/N 10069 ECN08-0066 POWER SUPPLY RATINGS AND SETTINGS INTERNAL 24 VDC (nom) 3.0A MAIN POWER SUPPLY This supply's primary function is to power panel logic and all external operations of the FIP, i.e.: detectioncircuits, ancillary circuits, etc. T...
Page 14 - EXTERNAL 27VDC POWER SUPPLY; BATTERY TYPE AND CAPACITIES
Page 10 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 EXTERNAL 27VDC POWER SUPPLY This supply is used in addition to the internal power supply for large systems. Its primary function is to powerany additional ancillary loads of the FIP up to 7 amps. This supply meets the requir...
Page 15 - TECHNICAL DESCRIPTION; GENERAL; TRANSIENT SUPPRESSION
IFS-2600 Installation & Programming Manual Page 11 P/N 10069 ECN08-0066 TECHNICAL DESCRIPTION GENERAL The IFS-2600 in its most basic form comprises of three boards, the main control board, the main terminationboard and the power supply board. The main control board contains the Microprocessor, E...
Page 16 - AZF DESCRIPTION; OVERLOAD PROTECTION
Page 12 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 AZF DESCRIPTION The AZF's on the IFS-2600 are monitored and scanned by custom thick film hybrids. These hybrid IC's significantly reduce the possibility of false alarms and improve product efficiency and reliability. The tot...
Page 17 - PRINTER OUTPUT; PROGRAMMING BY COMPUTER
IFS-2600 Installation & Programming Manual Page 13 P/N 10069 ECN08-0066 PRINTER OUTPUT The printer port is designed to be used during testing and commissioning of the panel. The serial printer willreport alarms and faults together with the date and time of the event. The printer can also be used...
Page 18 - ALIGNMENT AND ADJUSTMENT; INTERNAL 27.3 VDC BATTERY CHARGER; INTERNAL 5VDC POWER SUPPLY TP8; POWER SUPPLY COMPARATOR REFERENCE VOLTAGE TP10; NON ADJUSTABLE TEST POINTS
Page 14 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 ALIGNMENT AND ADJUSTMENT PCB2006 POWER SUPPLY BOARD INTERNAL 24VDC (nom) POWER SUPPLY W ith batteries disconnected and no alarms present, measure voltage across the 0V and MAIN testpoints on the 2006 power supply board and, ...
Page 19 - ALARM THRESHOLD COMPARATOR TP7; FAULT THRESHOLD COMPARATOR TP6
IFS-2600 Installation & Programming Manual Page 15 P/N 10069 ECN08-0066 ALARM THRESHOLD COMPARATOR TP7 W ith the panel in the quiescent mode, measure and take note of the INTERNAL 24V DC POW ERSUPPLY as above. Measure voltage between system 0V and TP7. Adjust multi-turn potentiometer VR4, and ad...
Page 20 - CONFIGURATION JUMPERS; IFS2006 – JP1 EXTERNAL PS MONITORING
Page 16 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 CONFIGURATION JUMPERS IFS2004 - JP3 DEFAULT Holding a short across these pins for 5 seconds during start-up causes the panel to reset to standardfactory defaults. The panel will give 4 beeps after reset, to acknowledge defau...
Page 21 - PLACING INTO OPERATION; EQUIPMENT AS FITTED; QTY; INITIAL CHECKLIST
IFS-2600 Installation & Programming Manual Page 17 P/N 10069 ECN08-0066 PLACING INTO OPERATION Suitably qualified technicians must install the panel. The following check procedures are recommended afterevery installation and prior to initial power-up. A thorough visual inspection should be made ...
Page 22 - POWER UP CHECKLIST
Page 18 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 POWER UP CHECKLIST Ensure batteries are disconnected. Turn mains switch to "on" The "mains on" led should light. Allow 15 seconds for the panel to perform its start up tests. Connect batteries FUNCT...
Page 23 - FAULT RECORD
IFS-2600 Installation & Programming Manual Page 19 P/N 10069 ECN08-0066 FAULT RECORD FAULT CORRECTION DATE TESTS SATISFACTORILY COMPLETED. TESTED BY _______________________________ SIGNATURE _______________________________ DATE OF TEST ____________________________ If all faults have been rectifi...
Page 24 - INSTRUCTIONS TO OPERATORS; INDICATORS
Page 20 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 INSTRUCTIONS TO OPERATORS INDICATORS Qty Descriptor Colour Function Buzzer 1 MAINS ON Green Illuminates when there is 200/220/240 VAC supply tothe panel. 1 BATTERYFAULT Yellow Illuminates if the battery fails a battery test....
Page 25 - FIREFIGHTER FUNCTIONS
IFS-2600 Installation & Programming Manual Page 21 P/N 10069 ECN08-0066 SUGGESTED ALARM PROCEDURE The following is a suggested alarm procedure for use by building fire officers or duty wardens. The fire indicator panel is designed for use by qualified fire fighters and it is strongly recommended...
Page 26 - GLOBAL FUNCTIONS
Page 22 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 BELL ISOLATE EXT BELL ISOL Depressing the "EXT BELL ISOLATE" key will isolate the bells. The "Ext Bells Isolate" LED will illuminate andthe bells will not sound until the bells are de-isolated. Pressing "...
Page 27 - WALK TEST MODE; ACF ISOLATE
IFS-2600 Installation & Programming Manual Page 23 P/N 10069 ECN08-0066 WALK TEST MODE WALKTEST This function will place the panel into "walk test" mode. W alk test mode is used for the on-site testing ofdetector zones. This mode cannot be selected if any zone(s) is in alarm. Entry to wa...
Page 28 - ZONE FUNCTIONS; ALARM TEST
Page 24 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 ZONE FUNCTIONS Zone functions are those relating specifically to the detection zones. Following is an explanation of theiroperation and the keystrokes required to perform the function required. ALARM TEST ALARM TEST # ENT Th...
Page 29 - FAULT TEST
IFS-2600 Installation & Programming Manual Page 25 P/N 10069 ECN08-0066 FAULT TEST FAULT TEST # ENTER The fault test function momentarily disconnects the detection zone(s) under test and simulates the worst-casecondition for fault. A resistor load equal to worst case fault is placed on the zone ...
Page 31 - PROGRAMMING; GLOBAL OPTIONS; ANCILLARY TRIP; ZONE OPTIONS
IFS-2600 Installation & Programming Manual Page 27 P/N 10069 ECN08-0066 PROGRAMMING GLOBAL OPTIONS ANCILLARY TRIP 1 LATCHING NORMALLY DE-ENERGISED 2 NON-LATCHING NORMALLY DE-ENERGISED 3 LATCHING NORMALLY ENERGISED 4 NON-LATCHING NORMALLY ENERGISED ALARM VERIFICATION 1 DISABLED 2 2 MINUTES 3 3 MI...
Page 32 - OUTPUT RELAY OPTIONS
Page 28 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 OUTPUT RELAY OPTIONS Optional Relays can be programmed to simulate: - Isolate Relay ACF Output Brigade Relay #1 Brigade Relay #2 Fault Relay Mains Fail Relay General Alarm Relay Bell Output Door Holder Rela...
Page 33 - PROGRAMMING MODE
IFS-2600 Installation & Programming Manual Page 29 P/N 10069 ECN08-0066 PROGRAM MODE Press the following buttons in order shown to enter programming mode. PREVIOUS → NEXT → SELECT → EXIT → ENTER PROGRAMMING MODE The liquid crystal display will display all messages and prompts required to program...
Page 34 - RELAYS; MAIN MENU
Page 30 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 RELAYS TYPE MAPPING ISOLATE RELAYANCILLARY OUTPUT (ACF)BRIGADE RELAY #1BRIGADE RELAY #2FAULT RELAYMAINS FAIL RELAYGENERAL ALARM RELAYBELL OUTPUTDOOR HOLDER RELAYMAP - AND (00)(00)(00)(00)(00) MAP - OR (00)(00)(00)(00)(00) MA...
Page 35 - EXIT PROGRAMMING MODE; ZONE PROGRAMMING; ZONE SELECTED; ZONE TYPE
IFS-2600 Installation & Programming Manual Page 31 P/N 10069 ECN08-0066 EXIT PROGRAMMING MODE SAVE CHANGES YES (NO) Use the "NEXT" & "PREVIOUS" keys to scroll through "YES" & "NO". Once the desired option has beenhighlighted, pressing the "SELECT" ...
Page 36 - ZONE OUTPUT CONFIGURATION; RELAY PROGRAMMING MODE; RELAY SELECTED
Page 32 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 Once the desired option has been highlighted, pressing the "SELECT" button will select it. Making a selectionor pressing "EXIT" will return to zone selected. Note: The option previously set is displayed in br...
Page 37 - RELAY TYPE; GLOBAL PROGRAMMING
IFS-2600 Installation & Programming Manual Page 33 P/N 10069 ECN08-0066 RELAY TYPE RELAY #ALL TYPE (GENERAL) Use the "NEXT" & "PREVIOUS" keys to scroll through: ISOLATEANCILLARYBRIGADE 1BRIGADE 2FAULTMAINS FAILGENERALBELLDOOR HOLDERMAP -AND-MAP -OR-MAP –FAULT-MAP –ISOLATE-MAP...
Page 39 - PRINT PROGRAMMING DATA
IFS-2600 Installation & Programming Manual Page 35 P/N 10069 ECN08-0066 Then relay #1 would be set as MAP OR with its mapping as (09) 00 00 00 00, relay #2 would be set as MAPOR with it’s mapping set as (10) 00 00 00 00 and so on all the way up to relay #64. Note: In example 2, zone number 64 is...
Page 40 - APPENDIX A; DESCRIPTION OF ALARM ZONE TYPES; LATCHING TYPE
Page 36 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 APPENDIX A DESCRIPTION OF ALARM ZONE TYPES Different zone types can be selected using the programming mode. Each zone can be selected as any one ofthe following: Type Description Input Delay 1 Standard Latching 2 seconds 2 S...
Page 41 - TIME DELAY AZF
IFS-2600 Installation & Programming Manual Page 37 P/N 10069 ECN08-0066 TIME DELAY AZF The time delay AZF zone can be preset to any one of 6 time delays in the initial setup. This type of zone isused for AS1668 smoke detection zones. Zone timing etc is as per AS1668-1991. Example: Timer #1 = 60 ...
Page 42 - APPENDIX B; ZONE OUTPUT CONFIGURATIONS
Page 38 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 APPENDIX B ZONE OUTPUT CONFIGURATIONS Once a zone has alarmed, its output functions as programmed to one of the following output types. Type Output Description 1 Indicate Only 2 Indicate, Bell 3 Indicate, Bell, General Alarm...
Page 43 - APPENDIX C; GLOBAL PROGRAMMABLE OPTIONS
IFS-2600 Installation & Programming Manual Page 39 P/N 10069 ECN08-0066 APPENDIX C ALARM VERIFICATION FACILITY (AVF) Alarm verification (AVF) is a facility used to minimise false alarms. AVF only applies to the zones programmed for the AVF function. GLOBAL PROGRAMMABLE OPTIONS AVF TIMEOUT Disabl...
Page 44 - APPENDIX D
Page 40 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 APPENDIX D ANCILLARY TRIP (ACF) The ancillary trip is used for the shutting down of air conditioning systems etc. in the event of a fire. GLOBAL PROGRAMMABLE OPTIONS ANCILLARY TRIP (ACF) NON-LATCHING ND LATCHING ND NON-LATCH...
Page 45 - APPENDIX E; RELAY OUTPUT MAPPING; AND MAPPING; OR MAPPING; FAULT MAPPING
IFS-2600 Installation & Programming Manual Page 41 P/N 10069 ECN08-0066 APPENDIX E RELAY OUTPUT MAPPING A total of 64 expansion relays can be fitted to the IFS-2600. Each relay can be individually programmed tomimic any of the following; STANDARD OUTPUTS WHICH MAY BE MIMICED ANCILLARY OUTPUT (AC...
Page 46 - FAULT/ISOLATE MAPPING; ISOLATE MAPPING
Page 42 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 FAULT/ISOLATE MAPPING FAULT/ISOLATE MAPPING works the same as OR mapping of alarm except it relates to thefault/isolate flag on each zone instead of the alarm flag. This function will cause the relay to operate if any one of...
Page 47 - APPENDIX F; GLOSSARY OF TERMS
IFS-2600 Installation & Programming Manual Page 43 P/N 10069 ECN08-0066 APPENDIX F GLOSSARY OF TERMS AS-4428.1 Australian standard for; -Automatic Fire Detection and Alarm Systems Control and Indicating Equipment. AS-4428.1 Australian standard for; -Automatic Fire Detection and Alarm Systems Pow...
Page 48 - APPENDIX G; SUMMARY OF TERMINATIONS AND CAUTIONS
Page 44 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 APPENDIX G SUMMARY OF TERMINATIONS AND CAUTIONS MCP LOOP Used for the looping of the manual call point to a particular zone chosen for indication. This is achieved bywiring from the zone, to the MCP, to the MCP loop then out...
Page 49 - BATTERY; OUTPUT RELAYS
IFS-2600 Installation & Programming Manual Page 45 P/N 10069 ECN08-0066 BATTERY The 24V batteries are connected at these terminals. Reverse polarity will cause serious and permanent damage to the equipment. DOOR HOLDER AC INPUT Terminate the door holder AC transformer at these terminals. 24 VAC ...
Page 50 - APPENDIX H; IFS-2600 PROGRAMMED OPTIONS
Page 46 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 APPENDIX H IFS-2600 PROGRAMMED OPTIONS Global System Parameters Date: / / Latch ND Non-Latch ND Latch NE Non-Latch NE ACF Output Disabled 2 min 3 min 4 min 5 min Alarm Verification(AVF) Notes: Programmed by Place an "X...
Page 51 - ZONE TYPE PROGRAMMING
IFS-2600 Installation & Programming Manual Page 47 P/N 10069 ECN08-0066 ZONE TYPE PROGRAMMING Date: / / 1 2 3 4 5 6 7 8 9 10 AZF No. STD STD N/L N/L T/D T/D T/D T/D T/D T/D 2S AVF 2S 20S 10S 20S 30S 40S 50S 60S 1234567891011121314151617181920212223242526272829303132 Place an "X" in the a...
Page 53 - ZONE OUTPUT PROGRAMMING
IFS-2600 Installation & Programming Manual Page 49 P/N 10069 ECN08-0066 ZONE OUTPUT PROGRAMMING Date: / / AZF No. INDICATE I- BELL IB- GENERAL IBG- ACF IBGA- BR1 IBGA- BR2 IBGA- BR1&BR2 1234567891011121314151617181920212223242526272829303132 Place an "X" in the appropriate box = Defa...
Page 57 - APPENDIX I; TECHNICAL DRAWINGS; MAIN KEYPAD AND DISPLAY
IFS-2600 Installation & Programming Manual Page 53 P/N 10069 ECN08-0066 APPENDIX I TECHNICAL DRAWINGS MAIN KEYPAD AND DISPLAY EXPANSION DISPLAY
Page 58 - Block Connection Diagram
Page 54 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 Block Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Norwest ...
Page 59 - System Sensor Conventional Detector Connection Diagram
IFS-2600 Installation & Programming Manual Page 55 P/N 10069 ECN08-0066 System Sensor Conventional Detector Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as appro...
Page 60 - Hochiki Conventional Detector Connection Diagram
Page 56 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 Hochiki Conventional Detector Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 ...
Page 61 - Ancillary Connection Diagram; FAN
IFS-2600 Installation & Programming Manual Page 57 P/N 10069 ECN08-0066 Ancillary Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Norw...
Page 62 - ASE Connection Diagram
Page 58 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 ASE Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Norwest Bu...
Page 63 - Auto Changeover Dual Sounder Connection Diagram
IFS-2600 Installation & Programming Manual Page 59 P/N 10069 ECN08-0066 Auto Changeover Dual Sounder Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 C...
Page 64 - Auto Change Over Dual Sounder Connection Diagram
Page 60 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 Auto Change Over Dual Sounder Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 ...
Page 65 - MIMIC Connection Diagram
IFS-2600 Installation & Programming Manual Page 61 P/N 10069 ECN08-0066 MIMIC Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Norwest ...
Page 66 - Single Fan Connection Diagram
Page 62 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 Single Fan Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Nor...
Page 67 - Dual Fan Connection Diagram
IFS-2600 Installation & Programming Manual Page 63 P/N 10069 ECN08-0066 Dual Fan Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Norwe...
Page 68 - Exhaust Fan Connection Diagram
Page 64 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 Exhaust Fan Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, No...
Page 69 - Supply Fan Connection Diagram
IFS-2600 Installation & Programming Manual Page 65 P/N 10069 ECN08-0066 Supply Fan Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Nor...
Page 70 - Smoke Spill Fan Connection Diagram
Page 66 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 Smoke Spill Fan Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court...
Page 71 - 0W EVAC Connection Diagram
IFS-2600 Installation & Programming Manual Page 67 P/N 10069 ECN08-0066 10W EVAC Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Norwe...
Page 72 - 0W EVAC Slave Connection Diagram
Page 68 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 10W EVAC Slave Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court,...
Page 73 - 0W EVAC Connection Diagram
IFS-2600 Installation & Programming Manual Page 69 P/N 10069 ECN08-0066 30W EVAC Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Norwe...
Page 74 - 0W EVAC Slave Connection Diagram
Page 70 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 30W EVAC Slave Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court,...
Page 75 - 0W EVAC Connection Diagram
IFS-2600 Installation & Programming Manual Page 71 P/N 10069 ECN08-0066 50W EVAC Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court, Norwe...
Page 76 - 0W EVAC Slave Connection Diagram
Page 72 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 50W EVAC Slave Connection Diagram 1 1 2 2 3 3 4 4 D D C C B B A A Rev Size Drg. No. Title Sheet: Drawn/Traced EngineerDesign Approved This Drawing must not be used for Construction unless signed as approved 7 Columbia Court,...
Page 77 - Notes