Page 2 - SAFETY; READ AND SAVE THESE INSTRUCTIONS
• • • • • • • • • • • • • • • DO NOT operate the unit with a damaged plug or loose wall outlet. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. DO NOT cover the air intake and exhaust when in use. DO...
Page 5 - Transportation, marking and storage for units.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your u...
Page 6 - WARNING
SYMBOL NOTE EXPLANATION WARNING This symbol shows that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire. CAUTION This symbol shows that the operation manual should be read carefully. CAUTION This symbol show...
Page 7 - Additional warnings for appliances with R32/R290
R32/R290 SAFETY Read the instruction carefully before using the appliance. R32/R290 refrigerant gas complies with European environmental directives. This appliance contains a certain number of grams (see rating label at the back of the unit) of R32/R290 refrigerant gas. The maximum refrigerant charg...
Page 9 - PARTS DESCRIPTION; 0) Power Cord Winder
2 PARTS DESCRIPTION EN 1) Louver 8) Upper Rubber Drain Plug (Dehumidifying Mode) 2) Control panel 9) Drain Tube(For Continuous Drain) 3) Handle 10) Power Cord Winder 4) Casters 11) Lower Dust Filter 5) Remote Control 12) Lower Rubber Drain Plug (Air Conditioning Mode) 6) Hose Connector 13) Storage P...
Page 10 - INSTALLATION; Window Bracket Kit
3 EN INSTALLATION It is important that the installation instructions below are followed for successful installation of thisLocal Air Conditioner. Please call Customer Support if you have any difficulties or queriesregarding these installation procedures. Installation Kit: Installation Steps: Exhaust...
Page 12 - Connect the window bracket to the window.
5 EN INSTALLATION (CONTINUED) Horizontal Sliding Window Vertical Sliding Window 4. Connect the window bracket to the window. 3. Connect the window bracket to the window bracket panel adapter. Ensure that all connections are tight and installed properly. 5. The Portable Air Conditioner is now ready t...
Page 14 - USE AND OPERATION; CONTROL PANEL; ) Swing Control Indicator Light; RESTART DELAY; Fan Speed cannot be adjusted in Sleep Mode and Dehumidifying Mode.; FAN SPEED CONTROL
7 USE AND OPERATION CONTROL PANEL FUNCTION BUTTONS 1) Display screen 5) Timer / Temperature Set Controls 2) Power Control 6) Mode Control 3) Fan Speed Control 7) Timer Control 4) Swing Control Indicator Light 8) Sleep Control EN Press to turn ON/OFF the unit. The air vent will automatically swing op...
Page 15 - is ON in Air; SLEEP MODE
8 USE AND OPERATION (CONTINUED) EN FUNCTION BUTTONS (CONTINUED) MODE CONTROL Settings: Air Conditioning, Dehumidifying, Fan.The corresponding indicator light will illuminate to indicate the current mode setting. Air Conditioning Mode (COOL)Adjust fan speed and air temperature to suit your desired co...
Page 16 - Press; WATER FULL LIGHT
9 USE AND OPERATION (CONTINUED) EN FUNCTION BUTTONS (CONTINUED) TIMER CONTROL While the unit is turned on, press the timer button then press the or to select the number of hours you would like the unit to continue to run. The unit will turn on/off automatically. AUTO TURN OFF: While unit is running,...
Page 17 - REMOTE CONTROL; All key functions can be accessed from the remote control.
10 Timer / Temperature Set Control In timer mode, press and to adjust the time setting for 1 hour intervals.Timer setting is available from 1 - 24 under cooling mode, press and to up or down the temperature. EN USE AND OPERATION (CONTINUED) REMOTE CONTROL All key functions can be accessed from the r...
Page 18 - CLEANING AND MAINTENANCE; Appliance Maintenance:; : You may use a vacuum cleaner to remove dust.; Dust Filter Maintenance:
11 CLEANING AND MAINTENANCE Appliance Maintenance: Turn off the appliance before disconnecting the power supply.Only clean the appliance with a soft dry cloth. 1.2. EN Switch off and unplug the Local Air Conditioner from the electrical outlet. Remove the Upper Filter/ Grill, unscrew the Lower Filter...
Page 19 - End of Season Storage and Maintenance:; If the appliance will not be used for a long time, follow these steps:
12 Be sure to drain the left-over water condensation. Remove the lower drain plug and use a drain pan to collect the water (make sure to replace the deain plug cap when finished).To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.Turn off and unplug the Local Air Con...
Page 20 - WATER CONDENSATION DRAINAGE; illuminates with a red light). This indicates that; Manual Draining in Cooling, Dehumidifying Modes
13 EN WATER CONDENSATION DRAINAGE When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (the WATER FULL indicator illuminates with a red light). This indicates that the water condensation needs to be drained using the following procedure...
Page 21 - TROUBLESHOOTING GUIDE; PROBLEM
14 TROUBLESHOOTING GUIDE The following troubleshooting guide addresses the most common problems. If problems persist, call customer support. Unplug and disconnect the appliance from the power source before attempting to troubleshoot. EN PROBLEM POSSIBLE CAUSE SOLUTION The air conditioningunit does n...
Page 23 - ERROR CODE GUIDE; ERROR CODE; Room temperature sensor failed
16 ERROR CODE GUIDE ERROR CODE POSSIBLE CAUSES SUGGESTED REMEDIES “E0” Room temperature sensor failed Replace room temperature sensor (the unit can also work without replacement.)Please contact the Customer ServiceCenter. “E1” Condenser temperature sensor failed Replace condenser temperature sensor ...