Summary

Page 4 - AIR CLEANER MONITOR; The BATTERY indicator is active when the W8600F battery is low.

69-0764—2 AIR CLEANER MONITOR The optional W8600F Air CleanerMonitor may be added to your aircleaner system to provide convenientindication of system performance. TheW8600F must be ordered seperately. The W8600F is designed to mount nextto your thermostat, or in any convenientlocation (such as a uti...

Page 5 - OPERATING YOUR ELECTRONIC AIR CLEANER

69-0764—2 When the fan and air cleaner come on, the neonindicator lights. If your air cleaner is equipped with a wall-mounted W8600F Air Cleaner Monitor (see page2), the ON indicator will be active whenever the air cleaner is in operation. Of course, the systemfan will also be running. Set the ON-OF...

Page 7 - GETTING THE MOST FROM YOUR ELECTRONIC AIR CLEANER

69-0764—2 For greatest benefit, the air cleaner should runall the time. To do this, set the fan switch onyour thermostat to ON, and make sure the aircleaner is switched ON. The fan and air cleanerwill run even when the furnace or air conditioneris off. NOTE: A manual fan switch may be built into the...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20

Summary

Page 2 - F58F COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER; ORDERING INFORMATION; IMPORTANT

F58F COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER 68-0141—4 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to theTRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, n...

Page 4 - PLANNING THE INSTALLATION; Application; Applications with Air Conditioning; Mount it as far as possible upstream from the air; Applications with an Activated Carbon Filter; Optional W8600F Air Cleaner Monitor; Choose F58F Location; WARNING

F58F COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER 68-0141—4 4 PLANNING THE INSTALLATION Application The F58F is used in a forced air heating, cooling, orventilating system. It removes airborne particles from the aircirculated through it. All models have an internal airflow switchto operate the F58...

Page 6 - Determine Duct Design Requirements; Transitions; Fig. 4. Change duct size gradually to minimize; Turning Vanes; Fig. 5. Typical use of duct offset to allow space for; INSTALLATION; When Installing this Product...; Unpack Electronic Air Cleaner

F58F COMMERCIAL DUCT MOUNTED ELECTRONIC AIR CLEANER 68-0141—4 6 Determine Duct Design Requirements The air cleaner is adaptable to all new or existing forced airheating, cooling and ventilating systems used in residentialapplications. Transitions, turning vanes, or offsets may beneeded in some appli...