Page 4 - THE SOLID STATE PERFORMANCE INDICATOR

THE SOLID STATE PERFORMANCE INDICATOR This electronic air cleaner is equippedwith a special solid state circuit thatoperates the optional W8600E SolidState Performance Indicator (seephoto). The W8600E Indicator must beordered separately. The W8600E Indicator is designed tomount next to your thermost...

Page 5 - OPERATING YOUR ELECTRONIC AIR CLEANER

You may hear a snapping (electrical arcing)sound occasionally as the air cleaner operates.This usually is caused by a larger dust particlecausing a high voltage discharge. The snappingsound means that your air cleaner is working as itshould. To hear the snapping sound, momentarilypress the test butt...

Page 7 - GETTING THE MOST FROM YOUR ELECTRONIC AIR CLEANER

For greatest efficiency, the air cleaner shouldrun all the time. To do this, set the fan switch onyour thermostat to ON, and make sure the aircleaner is switched ON. The fan and air cleanerwill run even when the furnace or air conditioneris off. NOTE: A manual fan switch may be built intothe furnace...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24

Summary

Page 2 - F50E DUCT MOUNTED ELECTRONIC AIR CLEANER; ORDERING INFORMATION; SPECIFICATIONS; IMPORTANT

F50E DUCT MOUNTED ELECTRONIC AIR CLEANER 68-0072—5 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to theTRADELINE® Catalog or price sheets for complete ordering number . 1. Order number. 4. Accessories, if desired. ...

Page 3 - Table 2. Shipping and Installation Weight.

F50E DUCT MOUNTED ELECTRONIC AIR CLEANER 68-0072—5 3 CAPACITY IN cfm (m /hr) 3 1 EFFICIENCY RATINGS BASED ON NATIONAL BUREAU OF STANDARDS INITIAL DUST SPOT METHOD USING ATMOSPHERIC DUST, AND AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS STANDARDS 52-76. 2 MINIMUM RECOMMEN...

Page 4 - PLANNING THE INSTALLATION; Application; Applications with Air Conditioning; Clean the air cleaner frequently to prevent a hard water

F50E DUCT MOUNTED ELECTRONIC AIR CLEANER 68-0072—5 4 M4697 UNIT SIZE IN. 16 X 25 20 X 25 MM 406 X 635 508 X 635 DIM. A 17-3/4 21-3/4 450 553 DIM. B 14-3/8 18-3/8 365 467 10-7/16 10-7/16 DIM. C 265 265 DIM. D 23-1/4 23-1/4 591 591 DIM. D (SEE TABLE) DIM. E (SEE TABLE) DIM. B (SEE TABLE) DIM. A (SEE T...