Page 3 - PLANNING THE INSTALLATION
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER 3 68-0198-2 Table 2. F111 Air Volume Specifications for 3 Speed Models (Series 3). a Same for Single Speed Models (Series 1 & 2). . Fig. 1. Approximate dimensions of F111 (Series 1,2,3) in in. (mm). Installation Weight: Approximately 115 lb to 155...
Page 4 - Choose Location; INSTALLATION; WARNING; CAUTION; When Installing this Product...; Unpack the Air Cleaner
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER 68-0198-2 Revised 5-09 4 WARNING TO REDUCE THE RISK OF FIRE,ELECTRICAL SHOCK, OR INJURY TO PERSONS,OBSERVE THE FOLLOWING: 1. Installation Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applica-ble Codes And Stand...
Page 5 - Mount Air Cleaner Cabinet
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER 5 68-0198-2 • latches (2) • 3-speed switch module ( 3 Series only) Make Opening (if Mounting in a Drop Ceiling) 1. Size the opening to fit the air cleaner cabinet as closely as possible. 2. Frame the opening to provide adequate support for the cabinet...
Page 6 - Remote 3 Speed Wall Switch (3 Speed Models only)
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER 68-0198-2 Revised 5-09 6 Fig. 5. Fasten cabinet to a structural support. IMPORTANT Do not touch the pleated filter media. Handle only the filter frame to prevent damage to the filter media. 11. Remove CPZ™ sorbent modules (select models) from their pa...
Page 7 - Lid Assembly; OPERATION
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER 7 68-0198-2 14. Connect one wire on air cleaner to power supply wire with a wire nut following color code used at remote switch. (White) 15. Connect the ground wire from the remote switch to a ground stud of the wiring compartment cover.(Green) 16. Fo...
Page 8 - SERVICE; Prefilter; CPZTM Adsorbent Module
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER 68-0198-2 Revised 5-09 8 Local, Federal and professional ventilation engineering standards and codes prescribe minimum ventilation rates to dilute air contamination in specific applications. The ventilation rates usually assume the injection of outdoo...
Page 9 - PARTS LIST
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER 9 68-0198-2 PARTS LIST Refer to Fig. 9 and Table 5 for replacement part information. Table 5. Replacement Parts. Fig. Reference No. Description Pack Qty Order Number 1 CPZ™ sorbent module (requires 2)—used with only 95% HEPA or 95% ASHRAE particle fil...
Page 11 - NOTES
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER 11 68-0198-2 NOTES
Page 12 - LIMITED TWO-YEAR WARRANTY
68-0198-2 Revised 5-09 www.cleanairfacility.com Air-Pure Systems 16873 Fish Point Rd. SEPrior Lake, MN 55372-1714Phone (800) 998-1919Fax: (800) 221-3248 LIMITED TWO-YEAR WARRANTY Air-Pure Systems warrants its air cleaner products to be free from defects in workmanship or materials under normal use a...