Page 2 - ABOUT THIS GUIDE; Related Documentation
WEB-700 WEB-700-O CP-700 95-7776—03 2 ABOUT THIS GUIDE This document covers the mounting and wiring of the Tridium® WEB/CP-700 (T-700) controller. It assumes that you are an engineer, technician, or service person who is performing control system installation. Instructions in this document apply to ...
Page 3 - PRODUCT DESCRIPTION; Packaging and Features
WEB-700 WEB-700-O CP-700 3 95-7776—03 PRODUCT DESCRIPTION The WEB/CP-700 controller is a compact embedded processor platform using on-board Flash memory for backup, in an expandable DIN-modular package. Designed for use in commercial environments, the WEB/CP-700 runs the NiagaraAX Framework to provi...
Page 5 - Technical Specifications; Equipment Ratings
WEB-700 WEB-700-O CP-700 5 95-7776—03 Technical Specifications WEB/CP-700 PLATFORM • PowerPC 440Epx @ 667MHz processor (speed approximate due to spread spectrum clock). • 1GB on-board NAND Flash storage. • 1 GB DDR-2 333Mhz RAM (maximum Java Heap size 384MB). • Two (2) Gigabit Ethernet ports. • Stan...
Page 6 - PREPARATION; Included in this Package; PRECAUTIONS; CAUTION; Safety Precautions
WEB-700 WEB-700-O CP-700 95-7776—03 6 PREPARATION Unpack the WEB/CP-700 and inspect the package contents for damaged or missing components. If damaged, notify the appropriate carrier at once and return any damaged components for immediate repair or replacement. See “Returning a Defective Unit” on pa...
Page 7 - WARNING; Static Discharge Precautions; Battery Precautions; MOUNTING; Environmental Requirements
WEB-700 WEB-700-O CP-700 7 95-7776—03 WARNING A 120Vac or 240Vac circuit powers the NPB-PWR-UN-H power supply for the controller. 15Vdc input (DC only) to controller. Disconnect power before installation or servicing to prevent electrical shock or equipment damage. Make all connections in accordance...
Page 8 - Physical Mounting
WEB-700 WEB-700-O CP-700 95-7776—03 8 Physical Mounting The following information applies about physically mounting the unit. • You can mount the WEB/CP-700 in any orientation. It it not necessary to remove the cover before mounting. • Mounting on a 35mm wide DIN rail is recommended. The WEB/CP-700 ...
Page 9 - Removing and Replacing the Cover
WEB-700 WEB-700-O CP-700 9 95-7776—03 To mount on DIN rail 1. Securely install the DIN rail with at least two screws, near the two rail ends. 2. Position the NPB-PWR-UN-H power supply module on the rail, tilting to hook DIN rail tabs over one edge of the DIN rail (Fig. 3). 3. Use a screwdriver to pr...
Page 10 - Board Layout
WEB-700 WEB-700-O CP-700 95-7776—03 10 Board Layout Fig. 5 shows the location of connectors, option slots, and other features of the main board in the WEB/CP-700. For side views of communications ports and other features, see Fig. 6, page 13. Fig. 5. WEB/CP-700 main board layout details A WEB/CP-700...
Page 11 - ABOUT EXPANSION OPTIONS; About Option Cards
WEB-700 WEB-700-O CP-700 11 95-7776—03 ABOUT EXPANSION OPTIONS The WEB/CP-700 provides for field-installable expansion using these types of options: • Option card — Install on connectors inside the WEB/CP-700 base unit. See About Option Cards, page 11. • Remote I/O modules — To wire to the WEB/CP-70...
Page 12 - About Remote I/O Modules
WEB-700 WEB-700-O CP-700 95-7776—03 12 OPTION CARD COM PORT ASSIGNMENTS COM port assignments for option cards installed in a WEB/CP-700 start at COM5, with Slot 1 evaluated first, then Slot 2. (COM1 and COM2 are always assigned to the onboard RS-232 and RS-485 ports, while COM3 and COM4 are reserved...
Page 13 - WIRING DETAILS; Communications Wiring
WEB-700 WEB-700-O CP-700 13 95-7776—03 WIRING DETAILS See Fig. 5, page 10 to locate connectors and other components on the WEB/CP-700 controller. Make connections to the WEB/CP-700 in the following order. 1. Install any option board (LON, RS-485, RS-232, etc.) in the available option slots. See Inst...
Page 14 - Grounding
WEB-700 WEB-700-O CP-700 95-7776—03 14 SERIAL There are two “RS” serial ports on the WEB/CP-700 base board. Each has a UART capable of operation up to 115,200 baud. At the bottom of the board (see Fig. 6, page 13) is an RS-232 port using an DB-9 plug (male) connector. On the right side of the unit i...
Page 15 - Power Wiring; L N
WEB-700 WEB-700-O CP-700 15 95-7776—03 Fig. 7. Grounding and power wiring connections to NPB-PWR-UN-H module. Power Wiring There are two power options for the WEB/CP-700 controller: the NPB-PWR-UN-H power supply module (typical), or a NPB- WPM-US (Wall Mount AC Adapter). NPB-PWR-UN-H The NPB-PWR-UN-...
Page 17 - Contact Inputs
WEB-700 WEB-700-O CP-700 17 95-7776—03 Contact Inputs Three contact inputs (CIs) are available on a 6-position connector next to the 2-position external battery connector. CIs are typically used to monitor normally-closed (N.C.) alarm contacts, if available on a UPS and/or the “door tamper” switch o...
Page 18 - EXTERNAL 12V BACKUP BATTERY
WEB-700 WEB-700-O CP-700 95-7776—03 18 EXTERNAL 12V BACKUP BATTERY A 2-position connector provides support for an external 12V sealed lead-acid (SLA) type rechargable battery. For more details, see About the Backup Batteries, page 20. Fig. 10. Sealed lead-acid backup battery connection on WEB/CP-700...
Page 19 - Wiring to Remote I/O Modules; POWER UP AND INITIAL CHECKOUT; Apply Power
WEB-700 WEB-700-O CP-700 19 95-7776—03 Wiring to Remote I/O Modules Wiring to remote I/O modules typically provides both 15Vdc power and 12V battery backup, along with RS-485 communications to the modules. See Fig. 11. Fig. 11. Power and RS-485 cabling between WEB/CP-700 and remote I/O modules POWER...
Page 21 - ABOUT LEDS; Status
WEB-700 WEB-700-O CP-700 21 95-7776—03 ABOUT LEDS The WEB/CP-700 provides a number of LEDs on its main board. Only the Status and Heartbeat LEDs are visible on the cover. Checking other LEDs requires first removing the cover. LEDs include the following types: • Status • Heartbeat • Debug • Ethernet ...
Page 22 - Required NiMH Battery Maintenance
WEB-700 WEB-700-O CP-700 95-7776—03 22 Required NiMH Battery Maintenance Battery life expectancy is a function of its discharge cycles (the number of discharges and their depth) and the ambient temperature of the battery during normal operation. In most applications, the NiMH battery should see rela...
Page 23 - REPLACEMENT PARTS; Non-replaceable Parts
WEB-700 WEB-700-O CP-700 23 95-7776—03 NOTE: Dispose of the used NiMH battery properly. 4. Unplug the NiMH battery from the main board connector (see Fig. 12). 5. Using a 1/4" (6mm) nutdriver, unfasten and retain the two kep nuts that secure the metal battery bracket to the shield, and remove th...
Page 25 - Returning a Defective Unit
WEB-700 WEB-700-O CP-700 25 95-7776—03 Returning a Defective Unit For proper credit on an in-warranty unit, ship the defective unit to Tridium within 30 days. NOTE: If the defective unit is under warranty, please follow return instructions provided in this section. If the unit is out of warranty, pl...
Page 26 - CERTIFICATIONS; Canadian Department of Communications (DOC)
WEB-700 WEB-700-O CP-700 95-7776—03 26 CERTIFICATIONS Federal Communications Commission (FCC) This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference with radio communications. It has been...
Page 27 - TAB MOUNTING DIMENSIONS
WEB-700 WEB-700-O CP-700 27 95-7776—03 TAB MOUNTING DIMENSIONS Measurements are in inches and (mm). DIN mounting is recommended over tab mounting. See Fig. 3, page 8. NOTE: Electronic and printed versions of this guide may not show the dimensions to scale. Verify all measurements before drilling. Fi...
Page 28 - Automation and Control Solutions
WEB-700 WEB-700-O CP-700 Automation and Control Solutions Honeywell International Inc.1985 Douglas Drive NorthGolden Valley, MN 55422customer.honeywell.com ® U.S. Registered Trademark© 2012 Honeywell International Inc.95-7776—03 M.S. Rev. 03-12 Printed in U.S.A. Fig. 14. WEB/CP-700 with power supply...