Page 2 - Place near an open door or window.; Note : Evaporative air cooler requires cross ventilation.; Turn ON and enjoy the cooling breeze.; QUICK START GUIDE
Fill with water and plug into a standardpower outlet. Place near an open door or window. Note : Evaporative air cooler requires cross ventilation. Turn ON and enjoy the cooling breeze. Note: Start with LOW speed and gradually increaseto higher speed for optimum cooling performance. Note: Please make...
Page 3 - SECTION
2. USER TIPS ......................................................... ........................................................ 3. SAFETY ...................................................................... ................................................ 4. PARTS DESCRIPTION ........................
Page 4 - THANK YOU
2 THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, please fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler. Cooler Location – Indoors (Important - Please...
Page 5 - USER TIPS; Energy Efficient, No Compressor
3 USER TIPS Pump Water Honeycomb Cooling Media Evaporative Air Cooling Mechanism Warm and dry air Cool and humid air Energy Efficient, No Compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor...
Page 6 - Indoor Use; Unit should be placed a minimum 10 inches away from any wall.; Outdoor Use
4 USER TIPS NOTE (Important - Please Read!) When the product is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate in a few hours or so of initial use. The recommended maximum relative humidity level is 60% orless, which allows a noticeable temperature decreas...
Page 7 - READ AND SAVE THESE INSTRUCTIONS:; SAFETY; Your cooler runs on 120 Volt, 60 Hz current. Check the
Water Level Indicator 5 READ AND SAVE THESE INSTRUCTIONS: SAFETY 120V ~ 60Hz Shock Hazard When using electrical appliances, basic safety precautions should always be followed: • • • • • • • • • Before operating the product remove it from its packaging and check that it is in good condition.DO NOT op...
Page 8 - will overload and damage the motor.
Floor Level 6 DO NOT attempt repair or adjust any electrical or mechanicalfunctions of the cooler, as this may void the warranty. DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. DO NOT insert or allow objects to enter any ventilation orexhaust opening as this ma...
Page 10 - 3 Rear Grill Removal Screws; PARTS DESCRIPTION
10 11 1 2 1 Tray for Tools 2 Side Panel 3 Control Panel4 Horizontal Louvers 5 Water Tank 6 Water Inlet Valve7 Casters 8 Water Level Indicator 9 Lever for Horizontal Louvers 10 Back Panel 11 Water Inlet Cover12 Water Drain Plug 13 Rear Grill Removal Screws 3 4 5 8 9 12 6 7 13 PARTS DESCRIPTION 8
Page 11 - CONTROL PANEL; POWER
CONTROL PANEL POWER SPEED SWING COOL 9 USE & OPERATION
Page 12 - CONTROL BUTTONS
CONTROL BUTTONS POWER SPEED SWING COOL USE & OPERATION 10 POWERPress to switch the unit ON or OFF. SPEEDPress to adjust the fan speed between Low and High speed. COOLTo begin cooling the desired area, press the COOL button. The water pump will operate and you will feel the cooler air after the h...
Page 13 - FILLING WITH WATER ( Continuous Water Supply Connection)
• Connect a garden hose connector to the water inlet valve, • Maximum water inlet pressure 0.5 MPa. • Water tank can be refilled by using water inlet hole on the top of unit. Make sure garden hose connector is well screwed with waterinlet valve. • Connect water supply to the garden hose, and turn on...
Page 14 - CLEANING & MAINTENANCE
IMPORTANT WARNING • • • • • The cooler is supplied with Honeycomb Cooling Media.The cleaning frequency for the Honeycomb Cooling Media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and rest...
Page 16 - TROUBLESHOOTING GUIDE
No discharge of air Cord is not plugged in. Make sure power cord isplugged in and the supplyswitch is ON. Power is not ON. Turn the unit ON by pressingbutton on the control panel. Not Cooling / Unit ismaking noise Pump is not turned ON. Turn on COOL function from Control Panel Low or no water in tan...
Page 17 - NOTE; TECHNICAL SPECIFICATIONS
MODEL NO. CO25MM 120V 60Hz 190 Watts 6.6 Gallons Honeycomb 24.0(L) x 19.0(W) x 32.5(H)inch 46.3 lbs Voltage Frequency Wattage 1.58 A Ampere Water Tank Capacity Cooling Media Product DimensionNet Weight This unit is supplied with three (3) Honeycomb Cooling Media’s located on the back & two sides...
Page 18 - ELECTRICAL WIRING DIAGRAM
Page 19 - SERVICE AND WARRANTY
1-YEAR LIMITED WARRANTY Read all the instructions before attempting to use this product. This 1 year limited warranty applies to repair or replacement product found to be defective in material or workmanship. At its option, JMA NORTH AMERICA LLC will repair or replace this product if it is found to ...
Page 20 - Model
Please read the Instruction Manual carefully before setting up or using this product. If you believe this product to be suffering from a manufacturing fault, or if you have inquiries about this product, please contact our Customer Support: D. CUSTOMER SUPPORTJMA North America LLCMahwah, New Jersey 0...
Page 21 - GUÍA DE INICIO RÁPIDO; Encienda y disfrutar de la brisa fresca.
GUÍA DE INICIO RÁPIDO Llene con agua y conecte a una toma decorriente estándar. Colocar cerca de una puerta o ventanaabierta. Nota: Enfriadores de aire por evaporación trabajan conel mecanismo de enfriamiento por evaporación querequiere una ventilación cruzada Encienda y disfrutar de la brisa fresca...
Page 22 - SECCION
2. CONSEJOS PARA EL USUARIO ........................................................................3. REGLAS DE SEGURIDAD ...................................................................... ................................................ 4. DESCRIPCIÓN DE PARTES ...................................
Page 24 - CONSEJOS PARA EL USUARIO
21 CONSEJOS PARA EL USUARIO Bomba Agua Medio de enfriamiento Honeycomb Mecanismo de enfriamiento de aire por Evaporación Aire Cálidoy seco Aire Húmedoy frío FRÍO ~ EFICIENTE ~ NATURAL El enfriamiento de aire por evaporación es la manera más natural de enfriamiento, similar a unabrisa que recorre un ...
Page 26 - LEER Y GUARDAR ESTAS INSTRUCCIONES:; REGLAS DE SEGURIDAD
Indicador de Nivel de Agua 23 LEER Y GUARDAR ESTAS INSTRUCCIONES: REGLAS DE SEGURIDAD 120V ~ 60Hz Peligro De Descarga Electrica Cuando se usan aparatos eléctricas, las precauciones básicas de seguridad siempre se debenseguir: • • • • • • • • • Antes de utilizar el producto de sacarlo de su embalaje ...
Page 27 - Coloque la unidad en un piso nivelado.
Nivel Del Piso 24 NO intente reparar o ajustar cualquier función mecánica oeléctrica del enfriador, ya que esto puede anular la garantía.NO cubra la salida o entrada de aire en el enfriador, ya que esto puede causar daños al motor. NO introduzca ni permita que objetos ingresen en le sistema de venti...
Page 29 - 3 Desmontaje de tornillos de la parrilla trasera; DESCRIPCIÓN DE PARTES
10 11 1 2 1 Bandeja de Herramientas2 Panel Lateral 3 Panel de Control4 Rejillas Horizontales5 Tanque de Agua 6 Válvula de Entrada de Agua7 Ruedas 8 Indicador de Nivel de Agua9 Palanca para Persianas Horizontales10 Panel Trasero11 Tapa para Entrada de Agua12 Tapón de Drenaje 13 Desmontaje de tornillo...
Page 30 - PANEL DE CONTROL; USO Y OPERACIÓN
PANEL DE CONTROL POWER SPEED SWING COOL 27 USO Y OPERACIÓN
Page 31 - BOTONES DE CONTROL
BOTONES DE CONTROL ENCENDIDO (POWER)Conectar el cable de alimentación para ENCENDER/APAGAR el enfriador . Cada vez que ENCIENDA/APAGUE el ajuste de VELOCIDAD ENFRIADO/CAMBIO DE TEMPERATURA, dependerá del estado de su propio botón. VELOCIDAD (SPEED)Encender la velocidad del ventilador entre el Nivel ...
Page 33 - LIMPIEZA Y MANTENIMIENTO
IMPORTANTE PRECAUCIÓN • • • • • El equipo se entrega con el medio de enfriamiento Honeycomb.La frecuencia de limpieza del medio de refrigeración filtro Honeycomb depende de las condiciones del aire y agua. En las zonas donde el contenido del mineral del agua es alta, los depósitos de los minerales p...
Page 34 - Conectar a la toma corriente y encender el equipo.
Soporte Honeycomb (panal) Soporte Honeycomb (panal) Tornillo Tornillo Honeycomb Honeycomb Panel Trasero Panel Trasero Panel Trasero Panel Lateral LIMPIEZA Y VACIAMIENTO DEL TANQUE DE AGUA LIMPIEZA EL MEDIO DE ENFRIAMIENTO HONEYCOMB • • • • • • • • • • Fig.1 Fig.2 Apagar el equipo y desconectar de la...
Page 35 - GUIA DE SOLUCION DE PROBLEMAS
No hay salida de aire Cable eléctrico no estaconectado Asegúrese que el cable eléctricoeste enchufado y el interruptorde alimentación en ON La unidad no esta encendida Intente prender la unidad apretando los botones en el panelde control No enfría / La unidad hace ruido Bomba de agua no esta prendid...
Page 36 - NOTA; ESPECIFICACIONES TÉCNICAS
MODELO NO. CO25MM 120V 60Hz 190 Watts 25 Litros Honeycomb 610(W) x 480(D) x 825(H)mm 21 kg Tensión Frecuencia Vatio 1,58 A Amperes Capacidad del tanque de agua Medios de enfriamiento Dimensiones del ProductoPeso Neto Este equipo se suministra con tres (3) Medios de refrigeración Honeycomb situado en...
Page 37 - DIAGRAMA DE CABLEADO ELÉCTRICO
34 DIAGRAMA DE CABLEADO ELÉCTRICO INTERRUPTOR DE ALIMENTACIÓN INTERRUPTOR DEL MOTOR MOTOR PARA MOVIMIENTO OSCILANTE BOMBA GIRAR ELINTERRUPTOR DEL MOTOR INTERRUPTOR DE LA BOMBA
Page 38 - GARANTÍA LIMITADA DE 1 AÑO; SERVICIO Y GARANTIA
A. B. C. GARANTÍA LIMITADA DE 1 AÑO Lea todas las instrucciones antes de intentar utilizar este produto. Esta garantía limitada de un año se aplica a la reparación o sustitución del producto siempre que haya algún defecto de material o de manipulación. Dado el caso, JMA NORTH AMERICA LLC reparará o ...