Honeywell 5002 - Manuals

Honeywell 5002 – Manual, Troubleshooting Guide, Installation Manual in PDF format online.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28

Summary

Page 3 - Included in your box:

3 AAA Also included: “Getting started” homeowner guide Thermostat Wall plate Anchors Screws Included in your box: Optional wall cover

Page 4 - Installation

4 Installation 1 Insert the recommended wall anchors It is recommended that you use the provided anchors when mounting your thermostat. Recommended drill bit size is 7/32 – 1/4-inch. Optional: Attach the optional wall cover to the wall plate If you choose to use the optional wall cover to hide blemi...

Page 8 - Wiring; Terminal Designations; Wiring Configurations; Two stage furnace and air-conditioning

8 Wiring Terminal Designations L Heat pump system monitor K Optional wire saver module C Common wire from secondary side of cooling transformer, if 2 transformers G Fan relay W2 (AUX) 2nd stage heat relay (heat pump auxiliary) Y2 2nd stage compressor contactor W (O/B) 1st stage heat relay (changeove...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13

Summary

Page 2 - FlashGuard 2000B Troubleshooting Guide

FlashGuard 2000B Troubleshooting Guide Page 2 Flashhead (Strobe) Problems START Flashhead works in at least one mode? No Are all of the LEDs OFF? Control Power ON, High Voltage OFF? No Control Power and High Voltage Both ON ? No Yes Day mode strobe is OK, Night strobe out? Section 1, pg. 4 Yes Yes Y...

Page 3 - Multiple Strobe Problems

FlashGuard 2000B Troubleshooting Guide Page 3 Multiple Strobe Problems . No Strobes are flashing out of sync. Yes Section 9, pg. 8 No Strobes have a ‘double flash’ or are flashing faster than 40 FPM? Yes Section 10, pg. 8 Master switches to night, but slaves stay in day mode? Yes Section 11, pg. 8 S...

Page 4 - Section 1; Flashhead does not operate in any mode, no LED’s on.; Section 2

FlashGuard 2000B Troubleshooting Guide Page 4 FLASHHEAD (STROBE) PROBLEMS Section 1 Flashhead does not operate in any mode, no LED’s on. Possible Cause : Input power incorrect. Diagnostic Test : Measure input power – it should be 120 VAC ±10%. Corrective Action: Supply correct input power. Possible ...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63

Summary

Page 2 - CONTENTS; HEMICALS

FITTINGS CONTENTS DUCTING ELECTRICAL INSTALL ITEMS EQUIPMENT PAD THERMOSTATS PUMPS TOOLS C HEMICALS A DHESIVES T APES S EALANTS UNIVERSAL PARTS

Page 4 - RX11-FLUSH 1LB CANISTER

CHEMICALS CLEANERS & DEGREASERS ADHESIVES | OILS & LUBRICANTS TAPE | SEALANTS ADHESIVES | | CHEMICALS | SEALANTS | SEALANTS | | CLEANERS & DEGREASERS SEALANTS | CLEANERS & DEGREASERS ADHESIVES | OILS & LUBRICANTS | TAPE | ADHESIVE OILS & LUBRICANTS | TAPE | | CLEANERS & D...

Page 6 - OZ OIL INJECTOR

RITCHIE 69562 4OZ OIL INJECTOR Adds oil or UV dye to system with ease. Easy connection to the manifold hose. OATEY 30891, PVC RAIN-R-SHINE BLUE CEMENT, 8 OZ. Use on all schedules and classes of PVC pipe and fittings up to 6" diameter with interference fit. BUY Y6630 BUY 44N97 CHEMICALS | CLEANER...

Honeywell Manuals