Page 5 - Electric; breaker, or unplug cord at wall receptacle.; Gas

Model OFE/OFG-321,322,323,324 2-5. POWER SWITCH (Continued) 4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel. 5. Replace with new switch, and reconnect wires to switch. 6. Replace the control panel. 2-6. TEMPERATURE PROBE The temperature...

Page 6 - REPLACEMENT; ELECTRIC

Model OFE/OFG-321,322,323,324 2-6. TEMPERATURE PROBE REPLACEMENT (Continued) ELECTRIC GAS 2-6 606

Page 7 - Tighten the compression nut hand tight and then a half turn; Excess force will damage temperature probe.

Model OFE/OFG-321,322,323,324 2-6. TEMPERATURE PROBE 7. Tighten the compression nut hand tight and then a half turn REPLACEMENT with wrench. (Continued) Excess force will damage temperature probe. 8. Connect new temperature probe to PC board and replace control panel. 9. Replace shortening. 10. Turn...