Henny Penny 680 KFC - Manuals
Henny Penny 680 KFC – Manual in PDF format online.
Manuals:
Manual Henny Penny 680 KFC
Summary
Henny Penny Model 680 HENNY PENNY 8 HEAD GAS PRESSURE FRYER Model 680 Gas Fryer SPECIFICATIONS Height 60" (152.4 cm) Width 24" (61 cm) Depth 41½" (106 cm) Floor Space Approximately 7 sq. ft. (.65 sq. m.) Pot Capacity 8 Head of chicken (24 lbs.)(10.9 Kg.)95 lbs. shortening (40.86 Kg.) Ele...
Henny Penny LIMITED WARRANTY FOR HENNY PENNY APPLIANCES Subject to the following conditions, Henny Penny Corporation makes the following limited warranties to the original purchaser only for Henny Penny appliances and replacement parts: NEW EQUIPMENT: Any part of a new appliance, except lamps and fu...
Henny Penny Model 680 Section Page Section 5. 5-1. Introduction ................................................................................................. 5-1 5-2. Arrangement ................................................................................................ 5-1 5-3. Maintenance...
Henny Penny Model 680 SECTION 1. INTRODUCTION 1-1. PRESSURE FRYER The Henny Penny Pressure Fryer is a basic unit of food processing equipment. It has found wide application in institutional and com- mercial food service operations . P-H-T A combination of Pressure, Heat, and Time is automatically co...
Henny Penny Model 680 3-3. MELT CYCLE OPERATION If the shortening is below 185 o F (77 o -85 o C) with the Power/ Pump Switch in the “Power” position, the fryer enters the melt cycle. The shortening is heate slowly to prevent scorching of the shortening. The display reads “LO” and the heat cycles, 1...
Henny Penny Model 680 5-7 COMPLETE CONTROL Should the Control Panel not operate, replace the panel as follows: PANEL - HENNY PENNY 1. Remove electrical power supplied to the fryer. Place the Power/Pump Switch in the “OFF” position, and unplug the power cord and/or turn off the wall circuit breaker, ...
Henny Penny Model 680 5-11. LID COUNTERWEIGHT (CONT’D) NOTE The cable should now have some slack in it, with the weightslevel. 10. Tighten the nut against the bracket, securing the cable. 11. Replace back shroud. Repair is now complete. 5-12. PRESSURE PAD The pressure pads are plastic strips that th...
Henny Penny Model 680 5-13. LID ADJUSTMENT If steam leaks out from around the lid gasket, the pressure padscould be worn or broken. If the pressure pad is worn, but notbroken, it can be reversed 180 degrees, and the other end of thepad used. See Section 5-12. Other problems could cause the steam to ...
Henny Penny Model 680 5-17. OPERATING CONTROL VALVE (Continued) DO NOT MANUALLY ACTIVATE THE SAFETY RELIEF VALVE. Hot steam will be released from the valve when the ring is pulled. Keep away from safety valve exhaust, or severe burns could result. Cleaning Steps 1. AT THE END OF EACH DAY’S USAGE OF ...
Henny Penny Model 680 5-18. REMOVAL & CLEANING 3. Clean inside of the elbow with hot water. OF SAFETY VALVE NOTE (Continued) Turn the relief valve towards the left side of the fryer when reinstalling relief valve. 4. Immerse the safety relief valve in soapy water for 24 hours. Use a 1 to 1 dilut...
Henny Penny Model 680 FIGURE UNITS & ITEM PART PER NO. NUMBER DESCRIPTION ASSY 1 36901 TOP LOUVER COVER ............................................................... 1 2 36190 CARRIAGE TRACK STUD ASSEMBLY, L.H .......................... 1 3 NS02-005 NUT, (#6-32 Hex Keps) .........................
Henny Penny Model 680 SMS PROGRAMMING 1. Press and hold the Function button for two seconds. (If Applicable) “REG PROGRAM” will show in the display, followed by“CODE”. 2. Press the code 1,2,3. “SELECT PRODUCT” will scrollacross the display. NOTE If no buttons are pressed, within approximately 1 minu...
Henny Penny Model 680 SMS PROGRAMMING 8. After the load compensation, press and release the Func- (Continued) tion button. “PROP” and “CONTROL” shows on theleft side of the display and the factory preset proportionalcontrol temperature shows on the right side of the display. 9. After the proportiona...
Henny Penny Model 680 SMS PROGRAMMING 13. After the filter value is set, press and release the Function (Continued) b u t t o n . “ E O C ” a n d “ E X I T ” f l a s h e s o n t h e l e f t s i d eof the display and “COOL” shows on the right side of thedisplay. The end-of-cycle, (EOC), exit point ca...
Henny Penny Model 680 SMS SPECIAL PROGRAM Reset Usage MODE (Continued) 1. Press and hold the Function button for two secondsuntil “REG PROGRAM” shows in the display. As soonas “REG PROGRAM” shows in the display, press andrelease the Function button 2 times until “RESET USE”shows in the display. 2. W...
Henny Penny Model 680 SMS SPECIAL PROGRAM 3. Press and release the Function button and “MELT”, MODE (Continued) “CYCLE”, and “100s” shows alternately in the display,along with the period (pulse) length of 4000. This shouldnot be changed until the factory is consulted. 4. Press and release the Functi...
Henny Penny Manuals
-
Henny Penny 291
Manual
-
Henny Penny PFG-691
Manual
-
Henny Penny OGA-342
Manual
-
Henny Penny 561
Manual
-
Henny Penny HEC-104
Manual
-
Henny Penny OFE-341
Manual
-
Henny Penny BCM-110
Manual
-
Henny Penny FDS-100
Manual
-
Henny Penny OFG-321 gas
Manual
-
Henny Penny MP-943
Manual
-
Henny Penny CSB
Manual
-
Henny Penny CBC/CBR-104
Manual
-
Henny Penny HHC-990
Manual
-
Henny Penny ESC-615 electric
Manual
-
Henny Penny BM-110
Manual
-
Henny Penny ODE-323 electri
Manual
-
Henny Penny BCF-110
Manual
-
Henny Penny OE-100
Manual
-
Henny Penny OFG-322
Manual
-
Henny Penny CSL
Manual