Page 4 - To avoid electrical shock or property damage, move the

Model 590/592 11. Pull excess capillary line from pot and tighten nut into frypot wall. Be sure capillary bulb of high limit is positioned so it does not interfere with carrier or get damaged when cleaning frypot. 12. With excess capillary line pulled out, tighten smaller nut. 13. Replace inner and ...

Page 5 - Label and remove wires from the switch.

Model 590/592 The POWER/PUMP switch is a three way rocker switch with a center OFF position. With switch in the POWER position, the fryer operates. With switch in PUMP position, the fi lter pump operates, but the unit will not heat. To avoid electrical shock or property damage, move the power switch...

Page 6 - Excess force will damage temperature probe.; Figure

Model 590/592 The temperature probe relays actual shortening temperature to the control. If it becomes disabled, “E06” will show in the dis-play. Also, if temperature is out of calibration more than 10°F, or 10°C, the temperature probe should be replaced. An Ohm check can be performed also. See char...