Page 2 - Table of Contents; WAN
HandyTone-488 User Manual Grandstream Networks, Inc. 2 Table of Contents 1 WELCOME ......................................................................................................... 3 2 INSTALLATION .................................................................................................
Page 3 - Welcome
HandyTone-488 User Manual Grandstream Networks, Inc. 3 1 Welcome Congratulations on becoming an owner of HandyTone-488. You made an excellent choice and we hope you enjoy all of its capabilities. Grandstream's HandyTone-488 is an all-in-one VoIP integrated access device that features superb audio qu...
Page 4 - Installation; Top View
HandyTone-488 User Manual Grandstream Networks, Inc. 4 2 Installation HandyTone-488 Analog Telephone Adaptor is an all-in-one VoIP integrated device designed to be a total solution for networks providing VoIP services. The HandyTone-488 VoIP functionalities are available via a regular analog telepho...
Page 5 - the telephone cable to a wall jack.
HandyTone-488 User Manual Grandstream Networks, Inc. 5 HandyTone-488 has one FXS port and one FXO port. The RJ11 jack next to the LAN port is a FXS port. The RJ11 jack on the side of the HandyTone-488 is a FXO port. Both the FXS port and the FXO port can have a separate SIP account. This is a key fe...
Page 6 - What is Included in the Package; Safety Compliances
HandyTone-488 User Manual Grandstream Networks, Inc. 6 3 What is Included in the Package The HandyTone-488 package contains: 1) One HandyTone-488 2) One universal power adaptor 3) One Ethernet cable 3.1 Safety Compliances The HandyTone-488 is compliant with various safety standards including FCC/CE ...
Page 7 - Product; Key Features; adaptive jitter control and packet loss concealment technology
HandyTone-488 User Manual Grandstream Networks, Inc. 7 4 Product Overview 4.1 Key Features • Supports SIP 2.0(RFC 3261), TCP/UDP/IP, RTP/RTCP, HTTP, ICMP, ARP/RARP, DNS, DHCP (both client and server), NTP, PPPoE, STUN, TFTP, etc. • Built-in router, NAT, Gateway and DMZ port forwarding • Supports cal...
Page 8 - Hardware Specification; UL
HandyTone-488 User Manual Grandstream Networks, Inc. 8 4.2 Hardware Specification The table below describes the difference among these models. Model HandyTone-488 LAN interface 1xRJ45 10Base-T WAN interface 1xRJ45 10Base-T FXS telephone port 1xFXS FXO port 1xFXO Button 1 LED Green and red color Univ...
Page 9 - Basic; Get Familiar with Voice Prompt; Direct IP Call
HandyTone-488 User Manual Grandstream Networks, Inc. 9 5 Basic Operations 5.1 Get Familiar with Voice Prompt HandyTone-488 has stored a voice prompt menu for quick browsing and simple configuration. To enter this voice prompt menu, simply press the button or “***” from the analog phone . Menu Voice ...
Page 10 - Make Phone Calls; Calling phone or extension numbers; Or; Direct IP calls; other SIP products) have public IP addresses, or; Input Meaning
HandyTone-488 User Manual Grandstream Networks, Inc. 10 5.2 Make Phone Calls 5.2.1 Calling phone or extension numbers To make a phone or extension number call: a) Dial the number directly and wait for 4 seconds (default “No Key Entry Timeout”) . Or b) Dial the number directly, and press # (assuming ...
Page 11 - followed by pressing the “#” key if; Blind Transfer; Attended Transfer; Attend Transfer
HandyTone-488 User Manual Grandstream Networks, Inc. 11 *4 : (column character) Examples: If the target IP address is 192.168.0.160, the dialing convention is Voice Prompt with option 47, then 192168000160 followed by pressing the “#” key if it is configured as a send key or wait 4 seconds. In this ...
Page 12 - dial tone; Send and Receive PSTN Calls; Call Features; Call Features Table; Key
HandyTone-488 User Manual Grandstream Networks, Inc. 12 1. A presses FLASH (on the analog phone, or Hook Flash for old model phones) to get a dial tone 2. A then dial C’s number then # (or wait for 4 seconds). A and C now in conversation. 3. A can hang up. Note: When intended Transfer failed, if A h...
Page 13 - PSTN Pass Through; LED Light Pattern Indication; RED LED
HandyTone-488 User Manual Grandstream Networks, Inc. 13 *50 Disable Call Waiting (for all subsequent calls) *51 Enable Call Waiting (for all subsequent calls) *70 Disable Call Waiting. (Per Call) *71 Enable Call Waiting (Per Call) *72 Unconditional Call Forward. To use this feature, dial “*72” and g...
Page 14 - GREEN LED
HandyTone-488 User Manual Grandstream Networks, Inc. 14 GREEN LED always indicates normal working status Message Waiting Indication Button flashes every 2 seconds RINGING Button flashes at 1/10 second RINGING INTERVAL Button flashes every second
Page 15 - Configuration; Configuring HandyTone-488 WAN IP through Voice Prompt; DHCP Mode; Configuring HandyTone-488 with Web Browser; Access the Web Configuration Menu; From the LAN port use the default LAN gateway IP address:; End User Configuration
HandyTone-488 User Manual Grandstream Networks, Inc. 15 6 Configuration Guide 6.1 Configuring HandyTone-488 WAN IP through Voice Prompt 6.1.1 DHCP Mode Follow section 5.1 with voice menu option 01 to enable HandyTone-488 to use DHCP. 6.1.2 STATIC IP Mode Follow section 5.1 with voice menu option 01 ...
Page 16 - Grandstream Device Configuration; End User
HandyTone-488 User Manual Grandstream Networks, Inc. 16 Grandstream Device Configuration Password Login All Rights Reserved Grandstream Networks, Inc. 2004 The password is case sensitive and the factory default password for End User is ‘123’. After a correct password is entered in the login screen, ...
Page 17 - Cloned WAN MAC; IP Address
HandyTone-488 User Manual Grandstream Networks, Inc. 17 NAT/DHCP Server Information & Configuration: Cloned WAN MAC Addr: (in hex format) LAN Subnet Mask: 255.255.255.0 (default is 255.255.255.0) LAN DHCP Base IP: 192.168.2.1 (base IP for the LAN port, default is 192.168.2.1) DHCP IP Lease Time:...
Page 18 - Time Zone; Yes
HandyTone-488 User Manual Grandstream Networks, Inc. 18 Time Zone This parameter controls how the displayed date/time will be adjusted according to the specified time zone. Daylight Savings Time This parameter controls whether the displayed time will be daylight savings time or not. If set to Yes, t...
Page 19 - MAC Address; System Up Time; This field shows whether the PPPoE connection is enabled or not.; Detected NAT Type
HandyTone-488 User Manual Grandstream Networks, Inc. 19 MAC Address The device ID, in HEX format. This is a very important ID for ISP troubleshooting. WAN IP Address This field shows WAN port IP address. Product Model This field contains the product model info. Software Version Program: This is the ...
Page 21 - Register; Voice Frames per
HandyTone-488 User Manual Grandstream Networks, Inc. 21 Name: John Doe (optional, e.g., John Doe) Register Expiration: 60 (in minutes. default 1 hour, max 45 days) local SIP port: 5062 (default 5062) local RTP port: 5008 (1024-65535, default 5008) Enable Call Features: No Yes (if Yes, Call Forwardin...
Page 23 - SIP Server’s URI or IP address
HandyTone-488 User Manual Grandstream Networks, Inc. 23 WAN side http access: No Yes (WAN side access to http server will be rejected if set to No) PSTN access code: (key pattern to use the PSTN line, default is "*00") Update All Rights Reserved Grandstream Networks, Inc. 2004 Admin Password...
Page 24 - This parameter sets the payload type for DTMF using RFC2833; SIP Registration
HandyTone-488 User Manual Grandstream Networks, Inc. 24 DTMF Payload Type This parameter sets the payload type for DTMF using RFC2833 Preferred Vocoder The HandyTone ATA supports up to 7 different Vocoder types including G.711 A-/U-law , G.723.1, G.726, G.728, G.729A/B, iLBC. Depending on the produc...
Page 25 - Default is No. Use only if proxy supports 484 response
HandyTone-488 User Manual Grandstream Networks, Inc. 25 Unregister on Reboot Default is No. If set to yes, the SIP user will be unregistered on reboot. Layer 3 QoS This field defines the layer 3 QoS parameter which can be the value used for IP Precedence or Diff-Serv or MPLS. Default value is 48. La...
Page 26 - Auto Upgrade
HandyTone-488 User Manual Grandstream Networks, Inc. 26 Keep-alive interval This parameter specifies how often the HandyTone ATA sends a blank UDP packet to the SIP server in order to keep the “hole” on the NAT open. Use NAT IP: NAT IP address used in SIP/SDP message. Default is blank. Proxy-Require...
Page 27 - Polarity Reversal
HandyTone-488 User Manual Grandstream Networks, Inc. 27 Disable Call Waiting Default is No. Polarity Reversal Default is No. If set to Yes, polarity will be reversed upon call establishment and termination. NTP server This parameter defines the URI or IP address of the NTP server which is used by th...
Page 28 - Saving the Configuration Changes; Your configuration changes have been saved.; Rebooting the HandyTone-488 from Remote; You may relogin by clicking on the link below in 30 seconds.
HandyTone-488 User Manual Grandstream Networks, Inc. 28 6.2.4 Saving the Configuration Changes Once a change is made, users should press the “Update” button in the Configuration page. The HandyTone-488 will then display the following screen to confirm that the changes have been saved. Grandstream De...
Page 29 - Configuration through a Central Server
HandyTone-488 User Manual Grandstream Networks, Inc. 29 6.3 Configuration through a Central Server Grandstream HandyTone ATAs can be automatically configured from a central provisioning system. When HandyTone ATA boot up, it will send TFTP or HTTP request to download configuration files, there are t...
Page 30 - Software; Upgrade through HTTP
HandyTone-488 User Manual Grandstream Networks, Inc. 30 7 Software Upgrade 7.1 Upgrade through HTTP To upgrade software, HandyTone-488 can be configured with an HTTP server where the new code image file is located. For example, following URL in the HTTP Upgrade Server: http://firmware.mycompany.com:...
Page 32 - Restore Factory Default Setting; Warning
HandyTone-488 User Manual Grandstream Networks, Inc. 32 8 Restore Factory Default Setting Warning : Restore the Factory Default Setting will delete all configuration information of the device. Please disconnect network cable and power cycle the unit before trying to reset the unit to factory default...