Page 2 - INDEX
(2/32) - Installation/Operation - 20i-T / 30i-T - V0612 INDEX 1 DRO description .......................................................................................... 3 1.1 Front panel ..................................................................................................................
Page 3 - DRO description; ABS; To get into and out of home search mode.
V0612 - 20i-T / 30i-T - Installation/Operation - DRO description - (3/32) 1 DRO description 1.1 Front panel Each axis display has eight 14.1mm high LEDs and another one for the minussign (-). Description of LED's and keys: ABS It stays on when operating in absolute mode and off when in incrementalmo...
Page 4 - Turning the unit on and off; It shows; Fagor dro; or the corresponding error code. See the error table and; Precautions
(4/32) - DRO description - Installation/Operation - 20i-T / 30i-T - V0612 1.2 Turning the unit on and off It turns on automatically when applying voltage or after pressing the on/offkey. It shows Fagor dro or the corresponding error code. See the error table and PAR11 for more options. Turns the DRO...
Page 5 - DRO operation; Fine / coarse resolution; led will turn on or off to indicate the double or actual reading; Z axis as a single axis or combination of both (Z; or the result from combining (adding) the positions of both
V0612 - 20i-T / 30i-T - Installation/Operation - DRO operation - (5/32) 2 DRO operation 2.1 Display modes MM / INCH conversion To display the position of the axes either in millimeters or inches by pressingthis key depending on whether the INCH led is off or on respectively. Fine / coarse resolution...
Page 7 - In incremental; -Press this key until the ABS LED is turned off.; At this point, one can proceed in two ways:; In case of a mistake, press this key to cancel it and leave it as it was.
V0612 - 20i-T / 30i-T - Installation/Operation - DRO operation - (7/32) 2.2.1 Example Using the lower figure, let us imagine we wish to make a part in which threeholes have to be drilled with the coordinates stated. It is clear that theblueprint will only reflect the incremental coordinates (I) or t...
Page 9 - Machine Reference selection and search; Access or exit the home search mode.
V0612 - 20i-T / 30i-T - Installation/Operation - DRO operation - (9/32) 2.3 Machine Reference selection and search Although it is not absolutely necessary, it is recommended to use thereference marks (Io) of the feedback system in order to set a machine zeropoint. This allows the user to reference t...
Page 10 - Operation with tools; To preset a tool, just follow this procedure:; calculator
(10/32) - DRO operation - Installation/Operation - 20i-T / 30i-T - V0612 2.4 Operation with tools 2.4.1 Tool Preset Up to 20 tools may be preset on this DRO model (from "tool 0" to "tool 19").The unit stores in its internal memory the relative offsets of all the tools withrespect to ...
Page 11 - Special operations; HOLD; Tool preset in HOLD mode.; factor
V0612 - 20i-T / 30i-T - Installation/Operation - DRO operation - (11/32) 2.5 Special operations 2.5.1 Scaling factor It is possible to apply a scaling factor within ±9.999 for mold makingapplications: The DRO will then show the axis position resulting from multiplying its realposition by the 'value'...
Page 12 - Tool change at any known point of the part:
(12/32) - DRO operation - Installation/Operation - 20i-T / 30i-T - V0612 Tool change at any known point of the part: - Touch the part with the tool. - Go into HOLD mode. The reading for that axis freezes with the current value. - Remove the tool to be replaced and insert the new one. - Approach the ...
Page 15 - DRO installation; Dimensions of the enclosure hole for inserting the DRO
V0612-20i-T / 30i-T - Installation/Operation - DRO installation - (15/32) 3 DRO installation 3.1 Installation of the built-in model Dimensions of the enclosure hole for inserting the DRO Built-in DRO insertion Bolt ISO 7380M4 x 10 Inox Nut DIN 985M4 Inox
Page 16 - On the back of the unit the following items may be found:; M6 mm terminal for general machine ground connection.; UL seal
(16/32) - DRO installation - Installation/Operation - 20i-T / 30i-T - V0612 3.2 Rear panel On the back of the unit the following items may be found: 1. Three-prong power connector for AC and ground connection. 2. M6 mm terminal for general machine ground connection. 3. Mounting bracket Some of the f...
Page 17 - WARNING; Do not handle the connectors while the unit is under power.; General technical characteristics; • Universal Power Supply between 100V AC and 240V AC ±10% at Mains
V0612-20i-T / 30i-T - Installation/Operation - DRO installation - (17/32) WARNING Do not handle the connectors while the unit is under power. Before handling the connectors (mains, feedback, etc.) make sure that the unit is not under power. It is NOT enough to turn the display off by using the [on/o...
Page 19 - The axis status will then switch to one of the following:; Ready; Installation parameters; to
V0612-20i-T / 30i-T - Installation/Operation - DRO installation - (19/32) The axis status will then switch to one of the following: Ready Correct feedback setup Repeat Wrong feedback setup, the process should be repeated. Error Error in the feedback system. Note: If the feedback device is a steel ta...
Page 20 - To get into parameter editing; COdE; To enter a parameter; ENTER; To quit the parameter editing mode:; displaying PAR00
(20/32) - DRO installation - Installation/Operation - 20i-T / 30i-T - V0612 To get into parameter editing The dro displays must be on, reading mode and press the following keys: The X axis display shows the word " COdE ". 060496 The displays of the DRO show PAR00 . Once in regular display mo...
Page 21 - Parameters to configure axis position reading and display.; PARAMETER
V0612-20i-T / 30i-T - Installation/Operation - DRO installation - (21/32) 3.7 Parameters to configure axis position reading and display. The digits of digital parameters refer to the digits on the axis displays so digit"1" (that can be changed with the [1] key) corresponds to the rightmost d...
Page 22 - External multiplying factor; when using distance-coded reference marks or
(22/32) - DRO installation - Installation/Operation - 20i-T / 30i-T - V0612 PAR02 TTL multiplying factor (subdivision). Independent for each axis. Options: x4, x2, x1 and x0.5. The factory setting is x4 and it is the one used for FAGOR linear encoders. When using rotary encoders on linear axes, it s...
Page 24 - Operate always in mm.; Binary type home search setting.; Digit; Direction of the distance-coded Io; To carry out a home search when the
(24/32) - DRO installation - Installation/Operation - 20i-T / 30i-T - V0612 Therefore, when using standard Io's, this parameter must be assigned thevalue of the distance from the machine zero point to the feedback referencepoint.Numeric value in resolution units for each axis. Factory setting: 0. Th...
Page 25 - Multi-point leadscrew error compensation.; because the compensation will not be applied until they; The compensation point must have at least one point with no error
V0612-20i-T / 30i-T - Installation/Operation - DRO installation - (25/32) PAR15 Multi-point leadscrew error compensation. Important: Before capturing data for an accuracy graph, the axis (axes) must behomed (referenced) because the compensation will not be applied until they are homed. To use this c...
Page 27 - Appendix; Warning; Fagor Digital Readout:; meets the following directives:; ELECTROMAGNETIC COMPATIBILITY:; Electromagnetic fields radiated by wireless telephones.
V0612 - 20i-T / 30i-T - Installation/Operation - Appendix - (27/32) 4 Appendix 4.1 UL seal See "UL seal" page 16. 4.2 CE seal Warning Before starting up the DRO, carefully read the instructions of Chapter 2 in the Installation Manual. The DRO must not be powered-on until verifying that the m...
Page 29 - Symbols which may appear on the manual; Symbols that may be carried on the product; “Electrical shock” symbol.; It indicates that point may be under electrical voltage.
V0612 - 20i-T / 30i-T - Installation/Operation - Appendix - (29/32) It is recommended to mount the DRO vertically, so its power switch of the back panel is at a distance between 0.7 m (27.5inches) and 1.7 m (5.6 ft) off the floor and away from coolants, chemicalproducts, blows etc that could damage ...
Page 30 - WARRANTY
(30/32) - Appendix - Installation/Operation - 20i-T / 30i-T - V0612 32 4.2.3 Warranty terms WARRANTY All products manufactured or marketed by Fagor Automation has a warrantyperiod of 12 months from the day they are shipped out of our warehouses.The mentioned warranty covers repair material and labor...
Page 32 - The plastics used in the front panel of the DRO stand up to:; Preventive; Ba San Andrés No 19
(32/32) - Appendix - Installation/Operation - 20i-T / 30i-T - V0612 32 4.4 Maintenance Cleaning: An accumulation of dirt in the equipment can act as a screen preventingproper dissipation of the heat generated by the internal electronic circuits withthe consequent danger of overheating and DRO fault....