Page 2 - Names and functions of each part; Installation service; Emergency operation; Do not dispose this product as unsorted municipal waste.
CONTENTS This symbol stands for the items should be forbidden. This symbol stands for the items should be followed ■ ..................................1 ■ ■ ................................ 10 ■ .................................... 15 ■ .......................... 20 ■ ..................................
Page 3 - Operation and maintenance-notices for operation; Be sure to pull out the power; Select the most appropriate tem-
★ ★ ★ Operation and maintenance-notices for operation 1 ★ ★ Be sure to pull out the power ★ ★ ★ ★ Earth: The groundbe connected! If not, please ask the qualified person- nel to install. Furthermore, don't conn-ect each wire to the gas pipe, water pipe, drainage pipe or any other impr-oper places. pl...
Page 4 - Notices for operation
2 ★ ★ ★ ★ ★ ★ ★ ★ Notices for operation If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. The airflow direction can be adjusted appro- priately. At operating, adjust the vertical airflow direction b...
Page 5 - Gentle Breeze; the guide louver rotate to a certain position:; Notices for use; Working principle and special functions for cooling; indoor
. Anti-cool wind function: In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within 3 mins): 1. Heating starts. 2.After Auto Defrost finished. 3.Heating under the ...
Page 6 - Outdoor unit; Air in
Names and functions of each part ⑸ ⑻ ⑶ ⑴ ⑵ ⑹ ⑸ ⑵ ⑻ ⑷ ⑺ ⑶ ⑴ Indoor unit Air in Air out Outdoor unit Wireless remote control Remote controlFront panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe ⑷ ⑹ ⑺ : Cool : Dry : Fan : Heat : Set temp. : Run The pattern in displayer : Air ...
Page 7 - 遥 控 器 各 按 键 的 名 称 及 作 用; Names and functions of wireless remote control; Remote control; Operation of wireless remote control; MODE
遥 控 器 各 按 键 的 名 称 及 作 用 5 Names and functions of wireless remote control ● Press this button, the unit will be turned on, press it once more, the unit will ON/OFF button Remote control Signal transmitter ● Press this button, Sleep On and Sleep Off can be selected. After powered on, SLEEP button Slee...
Page 8 - TEMP button; TURBO button
● Press this button, can select:setting temperature ( ), indoor ambient tempe- TEMP button rature( ),outdoor ambient temperature ( ).These temperature will show on theindoor unit display. The temperature on remote control is always setting temperature. 6 Remote control buttons of this control which ...
Page 9 - SWING UP AND DOWN BUTTON
Timer On setting: "ON" flashes and will conceal,numeral segment become timer-on setting status.Pressing or could adjust the numeral segment of time,increase or decrease 1minute per time within 5 seconds.If you hold pressing or , the numeral will change quickly after 2second.The way of the ch...
Page 10 - Introduction for special function; About; Guide for operation- General operation; About TURBO Function
start to blink and enter into clock adjustment status. Introduction for special function 1. After powered on, press ON/OFF button, the unit will start to run.(Note: When it is powered on, the guide louver of main unit will close automatically.) 2. Press MODE button, select desired running mode, or p...
Page 11 - About switch between Fahrenheit and Centigrade; °C and; About swing; Changing batteries and notices
4 . 2 . 3. ★ ● ● ● ● ● Slightly to press the place with , along the arrowhead direction to push the back cover of wireless remote control. (As show in figure) Take out the old batteries. (As show in figure) Insert two new AAA1.5V dry batteries, and pay attention to the polarity. (As show in figure) ...
Page 12 - Manual switch
If the wireless remote control is lost or broken, please use the manual switch Auto mode, but the temperature and fan button. At this time, the unit will run at the To open the panel, the manual switch is on the displayer box. It's a special selective buttonfor the users ,who are not accustomed to t...
Page 13 - temperature setting
1 1 ● ● ● ● Emergency Operation (only on some models) Emergency Operation When the wireless remote control is lost or damaged, please use the manual switch, at this time, it is running in Auto Run mode that will not change the temperature setting value and fan speed. The manual switch can be operate...
Page 14 - Clean and care; Caution; Take down the air filter; Insert the air filter
℃ ● ● ● ● ● ℃ ② Clean the air filter ③ ① ( a ) ( b ) Clean and care Caution Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Vo...
Page 15 - batteries; Maintain after use
① Be sure that nothing obstructs the air outlet and intake vents. ② ③ Check that whether the batteries of air conditioner are changed or not. ④ Check that whether the installation stand of the outdoor unit is damaged or not. If damaged, please contact the dealer. ① ② ③ ④ ⑤ Clean and care Check befor...
Page 16 - Troubleshooting; CAUTION; Phenomenon; the authorized
Once the air conditioner is stopped, it will not operate in approximately 3minutes to protect itself. ● ● ● ● ● ● Troubleshooting CAUTION Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can...
Page 18 - Immediately stop all operations and plug out, contact
● ● ● ● Troubleshooting Phenomenon Troubleshooting Indoor unit cannot deliver air . Moisture on air outlet vent . If unit is running under the high humidity for a long time, the moisture will be condensed on the air outlet grill and drip off. Immediately stop all operations and plug out, contact the...
Page 19 - This appliance has been made for air-conditioning domestic
1. 2. Select a position where the condensing water can be easily drained out, and the place is easily connected for outdoor unit. 4. Can select the place where is strong enough to withstand the full weight and vibration of the unit. And will not increase the noise. 5. 6. 7. 8. Make sure that the ind...
Page 20 - Notices for installation; Safety Requirements For Electric Appliances; Earthing requirements
Note: Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected, there should be reliable and no short circuit in the diagram. wrong connection may cause fire. ● ● 4. The min. distance from the unit and combustive surface is 1.5m. 1. Th...
Page 21 - Installation dimension diagram; Space to the wall
Space to the wall Above Above Installation dimension diagram Installation dimension diagram Space to the ceiling Space to the wall Space to the wall Air outlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above ...
Page 22 - Install indoor unit; Install the rear panel; Flooded; Connect indoor and outdoor electric wires; Remove the wiring cover
2 0 Install indoor unit 1 5 0mm φ 6 5mm φ 6 5mm 1 5 0mm Ø 65 5 Install the rear panel 1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is tak...
Page 23 - joint on the wire are not allowed.; Install the indoor unit
2 1 ● ● ● After tighten the screw, slight pull the wire and confirm whether is it firm or not. ● ● The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that Install indoor unit NOTE: When connecting the electric wire if the wire length is not enough, please contac...
Page 24 - Air purging and leakage test; Install outdoor unit; Open the vacuum pump to evacuate. At the beginning, slightly; INVERTER
Ø Air purging and leakage test Condensate drainage of outdoor unit (no for cooling only) The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Installation method:set the drain connection in 25 hole of the chassis has been installe...
Page 25 - Items to be checked; Test Operation
1. (1) Do not switch on power before installation isfinished completely. (2) Electric wiring must be connected correctly and securely. (3) Cut-off valves of the connection pipes should be opened. (4) 2. (1) Switch on power, press "ON/OFF" button on the wireless remote control to start the op...
Page 26 - Installation Instructions; Forcibly pull the panel for a specific angle; Installation and Maintenance of Healthy Filter; based on the actual delivery.
Fig. a Installation Instructions 1. Forcibly pull the panel for a specific angle from the two ends of the front panel accordingto the arrow direction. Then pull the air filter 2. Mount the healthy filter onto the air filter,(as shown in Fig.b). If the air filter cannot be in-stalled, please mount th...
Page 27 - TECHNICAL DATA; GENERAL INFORMATION
9 K 12 K 18 K 24 K 28 K General data Electricity supply 230~50 (*) V ~ Hz Refrigerant gas R 410 A (**) Fuse 10 10 16 20 20 A Minimum cable section 1,0 1,0 2,5 2,5 mm 1,5 Size and clearance L 845 845 940 1178 1178 mm H 275 275 298 326 326 mm P 180 180 200 253 mm 253 A 150 mm B 150 mm C 2500 mm D 150 ...