Summary

Page 3 - Set Up; some dual spd fans

MAN# 650264:B Set Up 1. Press and hold SW 2, then turn the key on. 2. Release SW 2, then press and release SW1 to move onto the next step. 3. To select temperature scale to use, press and hold SW1 to select (Fahrenheit) or press and hold SW 2 for (Celsius). Hold the switch for longer than one sec to...

Page 4 - points on the gauge.; lowest

MAN# 650264:B Custom Calibration Note 1: If your engine is warm you may need to disconnect the wire from your sender in order get to the lower points on the gauge. Note 2: If the key is turned off in custom setup, the previous gauge setting will be used and the custom gauge will not be saved. Note 3...

Page 5 - TROUBLESHOOTING; PROBLEM; Display reads “Er3”

MAN# 650264:B TROUBLESHOOTING PROBLEM CAUSE SOLUTION Display reads “Er0” (lost memory) Setup memory lost, unit needs to be recalibrated Go through setup procedure, (see setup in this manual) Display reads “Er1” (shorted sender) Wrong gauge selected Gauge disconnected from sender (gauge option only) ...