Wiring: BLACK - connect to a good ground point in the vehicle. RED - connect to switched 12 volt power point. (An accessory terminal will work for this.) ORANGE - connect to a constant 12 volt power point. (This will keep the correct time.) BLUE - connect to the tail light circuit. Mounting: The gau...
Troubleshooting guide. Problem Possible cause Solution Clock will not light up Red wire does not have Connect to a location that has power power. when the key is on. Orange wire does not have Connect to a location that has power power. all of the time. Black wire is not getting Connect ground to a d...
Technical specifications Minimum operating voltage - 7 volts Maximum operating voltage - 18 volts (operating at or near maximum rating for an extended time can damage unit) Clock accuracy - ± 2 minute per month Typical current draw (@ 13.8V) - 0.13 A Standby current draw (key off) - 0.002 A ODYSSEY ...