Page 2 - BEFORE BEGINNING
2 TABLE OF CONTENTS Pre-Installation Considerations……….………...……...…………………………………..……………………………………2 . Installation Cautions & Warnings…………….…….…………………………..……………………………….……..…..……3 3 Pin and 5 Pin connector ……....……….……………………………………………………………………….…..………....4 Power Door Lock Wiring …….…….………………...………………...
Page 3 - INSTALLATION CAUTIONS & WARNINGS; result in damage to the unit not covered under warranty.; DO NOT; PROGRAM/OVERIDE SWITCH AND LED; VALET / PROGRAM SWITCH
3 INSTALLATION CAUTIONS & WARNINGS **FOR SAFETY REASONS, DO NOT INSTALL in vehicles with MANUAL TRANSMISSIONS .** If accidentally left in gear, a remote started vehicle could become a self-propelled threat to life and property. DO NOT extend the Remote start ignition harness length. Mount the mo...
Page 5 - Plug-in pulse inverter that converts the; POWER DOOR LOCK WIRING CONNECTOR; DETERMINING DOOR LOCK TYPE:; POWER DOOR LOCK WIRING Cont.
5 Crimestopper Door Lock Accessories: CS-6600DLM: Dual-relay plug-in module for Reverse Polarity, Positive, or Aftermarket Motors. CS-6500DLI: Plug-in pulse inverter that converts the Negative outputs of the system to Positive type for Positive Door Lock systems. CS-610S1: Aftermarket door lock actu...
Page 6 - BASIC DOOR LOCK DIAGRAMS
6 BASIC DOOR LOCK DIAGRAMS NEGATIVE TRIGGER DOORLOCK W IRING POSITIVE TRIGGER DOORLOCK W IRING GREEN RED BLUE DIOD ES FACTORY FACTORY L L LOCK LOCK POW ER POW ER LOCKING LOCKING UL UL RELAYS RELAYS UNLOCK UNLOCK IN4001 DIODES IN4001 AFTERMARKET M OTOR/DOOR LOCK WIRING REVERSE POLARITY DOOR LOCK WIRI...
Page 7 - NEGATIVE TRIGGER DOOR LOCKS
7 PRIORITY DOOR LOCK DIAGRAMS (For EZ-55DP II/EZ-95FM II only) NEGATIVE TRIGGER DOOR LOCKS BLUE/W HITE GREEN RED BLUE DRIVER'S DOOR MOTOR 86 85 L L 87 UL UL 87A 30 FACTORY LOCK RELAYS +12V + FUSED UNLOCK WIRE CUT POSITIVE TRIGGER DOOR LOCKS FUSED+12V + 86 85 86 85 86 85 87 87 87 30 87A 30 87A 30 87A...
Page 8 - UL; REVERSE POLARITY DOOR LOCKS; GREEN
8 PRIORITY DOOR LOCK DIAGRAMS Cont. (For EZ-55DP II/EZ-95FM II only) FUSED+12V + 86 85 86 85 86 85 87 87 87 30 87A 30 87A 30 87A + L UL CUT UNLOCK WIRE LOCK WIRE DRIVER'S DOOR MOTOR REVERSE POLARITY DOOR LOCKS CUT CUT BLUE/WHITE GREEN RED BLUE Reverse Polarity: Many Ford/Lincoln/Mercury/Dodge/Chrysl...
Page 9 - WIRING; Trunk Soleniod
9 WIRING PIN 1: GREEN/RED: (-) AUX#1 OUTPUT (TRUNK POP) or DOME LIGHT ILLUMINATION OUTPUT This output is programmable for two modes of operation. See Programming Option Section. Mode (1) DEFAULTS: Provides a Ground pulse when button #3 (Trunk) on the remote transmitter is pushed to activate a factor...
Page 14 - IGN; START 2; Heavy duty/High Current Ignition circuits
14 WIRING: 6-PIN HIGH-CURRENT CONNECTOR PINK/WHITE: +12V MULTI-FUNCTION OUTPUT 30A (JUMPER SELECTABLE page 29): This is an optional multi-function output wire the can be configured as a Second IGN, ACC or STARTER output. Some vehicles require more than just one IGN, ACC, or STARTER wire in order to ...
Page 15 - “SMART TACHLESS” MODE; “SMART TACHLESS” ADJUSTMENT:
15 “SMART TACHLESS” MODE Your EZEESTART system includes a unique voltage monitor called “Smart Tachless” mode. This mode allows this unit to efficiently start an engine without the use of a tach signal wire. These modules actively monitor the voltage level of the vehicle to control the starter motor...
Page 16 - TACH FINDER & USEFUL TIPS; from starting and stalling in the morning or cold weather.
16 TACH FINDER & USEFUL TIPS TACH FINDER MODE: This Tach Finder mode can assist in locating a Tach source for your installation. W hen following the steps, the unit will begin to flash the parking lights if you have the W HITE/RED wire connected to a tach source. If lights do not flash, then try...
Page 17 - TACH PROGRAMMING & TACH SIGNALS; INTRODUCTION
17 TACH PROGRAMMING & TACH SIGNALS INTRODUCTION Tach signals will vary in levels and frequencies depending on many factors including the type of vehicle and the source of the signal. The signals from a vehicle’s injector wire and coil pack wire can vary greatly even on the same engine. The tach ...
Page 18 - TIMED CRANK MODE; HOW TO USE THIS FEATURE:; attempt and may require a 2
18 TIMED CRANK MODE This feature provides an easy method of starting the vehicle without locating an exact tach wire. The system uses a timed cranking output combined with the use of the W HITE/RED tach wire as an engine ON/OFF monitor. The W HITE/RED Tach wire must still be used in this mode of ope...
Page 19 - DIESEL GLOW PLUG DELAY; OPTIONS PROGRAMMING; OPTION PROGRAMMING CHART BEGINS ON NEXT PAGE
19 DIESEL GLOW PLUG DELAY This feature provides a solution for diesel vehicles without having to connect to the Glow Plug-“W ait to Start Circuit”. This may be needed for various reasons. If your vehicle does not have a viable “W ait to Start Circuit”, or you cannot locate and identify the circuit, ...
Page 20 - OPTIONS PROGRAMMING Cont.; To Engage Option Programming:; Pink wire must be connected!; OPTION PROGRAMMING TABLE; Option Description
20 OPTIONS PROGRAMMING Cont. To Engage Option Programming: 1. Open hood (If no hood pin switch is installed, then ground the Blue wire) 2. Turn Key to the ON position. (Do not start vehicle) Pink wire must be connected! 3. Press the program / valet button 5 times. W ait for the unit to flash the lig...
Page 21 - OPTION PROGRAMMING Cont.; FOR EZ-55DP II AND EZ-95FM II SERIES ONLY
21 OPTION PROGRAMMING Cont. Option Number Option Description TX Button #1 TX Button #2 TX Button #3 TX Button #4 12 Yellow/black wire function Anti-Grind *Ignition output* 13 Horn Chirp Confirmation 1 Press *2 Press* 14 Unlock with Trunk pop Unlock/Trunk pop *Trunk pop only* 15 Timed Crank or Tach M...
Page 22 - Double Button Press for Remote start and Trunk release:
22 OPTIONS PROGRAMMING Cont. OPTION DESCRIPTIONS: 1. Engine Monitoring: This option sets how the unit monitors your engine. You can program either for Tach mode in which the unit uses a Tach signal (RPM) or for Tachless mode that monitors voltage level. See pages 15-17 for more information and addit...
Page 23 - GREEN/RED Output Wire Function: Trunk Pop or Dome Light Output; press within 3; Unlock With Trunk Pop or Trunk Pop Only:
23 OPTIONS PROGRAMMING Cont. 7. Horn Chirps on Remote Start: This option allows the unit to provide 3 short chirps for audible confirmation of a remote start. The horn output wire must be connected for this feature. 8. Lock During/After Remote Start: This option controls whether the unit will automa...
Page 26 - TRANSMITTER PROGRAMMING; Transmitter Programming:; code, 4 flashes for the 3; code and 0 for 4
26 TRANSMITTER PROGRAMMING Transmitter Programming: Notes: Remote Transmitters/Transceivers come pre-programmed from the Factory. When re-learning remotes or adding remotes, ALL your system’s remote codes must be learned at time of programming!! These systems allow storage of up to 4 different remot...
Page 27 - EZEE ST ART; vehicle mode; VEHICLE 2 MODE; button for 2 second,; The; Way 5 button sidekick remote
27 START EZEE ST ART The Led will flash Orange & Green in 2 nd vehicle mode VEHICLE 2 MODE Press Middle (Star) button for 2 second, Then you have 3 sec. to control vehicle #2. 2-VEHICLE OPERATION The EZ-45DP II, EZ-55DP II and EZ-95FM II can be used for 2 vehicle operation. A single remote can c...
Page 28 - TROUBLESHOOTING: “BEFORE YOU CALL” SECTION; UNIT WILL NOT ATTEMPT TO START (KEYLESS ENTRY FUNCTIONS NORMALLY):
28 TROUBLESHOOTING: “BEFORE YOU CALL” SECTION UNIT WILL NOT ATTEMPT TO START (KEYLESS ENTRY FUNCTIONS NORMALLY): The unit is in Valet mode. Turn IGN ON, press and hold valet/programming button for 5-6 seconds then turn key off. Unit is now out of valet mode and should remote start. If optional LED i...
Page 29 - JUMPER PIN DIAGRAMS; SECURING JUMPERS
29 JUMPER PIN DIAGRAMS JUMPER PLUG SIDE VIEW JUMPER PINS JUMPE RS: PINK/WHITE = IGN #2 (DEFAULT) PINK/WHITE = ACC #2 ACC 2, IGN2, START2 PINK WHITE for GLOW PLUG PINK WIRE: Jumper Select for Postive or Negative Type "Wait" Circuits SECURING JUMPERS JUMPER PARKING LIGHT JUMPER WHITE WIRE: Jum...
Page 30 - ANTENNA DIAGRAM
Page 31 - WIRING DIAGRAM
31 WIRING DIAGRAM IGNITION 1 ACCESSORY BATTERY START ER (+) BRAKE SWITCH (-) HOOD SWITCH WHITE IGNITION SWITCH BLUE 30AMP FUSE FLASHING GREEN RED BLUE (-) LOCK / (+) UNLOCK +12V FOR RELAYS (-) UNLOCK / (+) LOCK OVERRIDE VALET/ STATUS LED LIGHTS (-) 500 mA OUTPUT RED: +12V (Heat/Air) PINK BROWN GRAY ...
Page 32 - DATA PORT DIAGRAM; They’re 2 types of; Please refer to Databus manual for detailed instructions.; Data Port; © 2006Crimestopper Security Products
DATA PORT DIAGRAM This unit includes DP Technology that will allow you to directly Plug-In our Data Port Bypass Modules. They’re 2 types of Protocol, 1-W ay (OFA modules) or 2-W ay (SL modules). The default is set for 2-W ay Protocol. This is controlled by option # 5 in the programming table on page...