Page 2 - FOR THE USER; IMPORTANT; RETAIN THIS MANUAL FOR YOUR REFERENCE.; WARNING; can cause property damage, injury or death.
FOR THE USER IMPORTANT THE INSTALLATION AND CONNECTION MUST COMPLY WITH THE LOCAL ANDNATIONAL ELECTRICAL CODES. ENSURE ELECTRICAL SUPPLY CONFORMS WITH ELECTRICAL CHARACTERISTICSSHOWN ON THE RATING LABEL ALL SERVICE MUST BE PERFORMED BY A QUALIFIED CLEVELAND RANGE TECHNI-CIAN. RETAIN THIS MANUAL FOR ...
Page 3 - TABLE OF CONTENTS; Installation; Operating Instructions
TABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Inspection / Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - INSTALLATION
1 GENERAL Installation of the unit must be accomplished byqualified electrical installation personnel workingto all applicable local and national codes.Improper installation of product could cause injuryor damage. This equipment is built to comply with applicablestandards for manufacturers. Included...
Page 5 - WIRE CONNECTION; WATER CONNECTION; CLEANING
2 WIRE CONNECTION Note: Ensure main power is turned off before connecting wires. General Information Install in accordance with local codes and/or theNational Electric Code ANSI/NFPA No. 70-1990(USA) or the Canadian Electric Code CSAStandard C22.1 (Canada). A separate fused dis-connect switch must b...
Page 6 - SPECIFICATION DRAWING
3 DPK(OPTION) 39" 991mm 35" 889mm (RIM HEIGHT) 71" 1804mm 75 28 3/4" 731mm (PAN SURFACE) A B (PAN SURFACE) 41" 1042mm H C 25 15/16" (659mm) 3 7/8" (99mm) C 5 1/4" (134mm) (FAUCETOPEN) 30" (762mm) 5" (127mm) (MANUAL TILT HANDLE) D RECOMMENDED FLOOR SLOPE 1"...
Page 7 - OPERATING INSTRUCTIONS
4 OPERATING INSTRUCTIONS General Parts Drawing ITEM # DESCRIPTION FUNCTION 1. Power Switch Lower position - power to the unit is OFF. Upper position - power to the unit is ON. 2. Temperature Dial Regulates the surface temperature of the pan. 3. Heat Indicator Light Turns ON when heating system is on...
Page 8 - OPERATING THE UNIT; OPERATING SUGGESTION; HOT
5 OPERATING THE UNIT 1. Ensure electrical supply to the unit is in the ONposition. 2. Turn Power Switch ( 1 ) to the ON position. The yel- low Heat Indicator Light ( 3 ) will indicate power is on. 3. MANUAL TILT ( 4 ) : Cleveland skillets are equipped with a manual tilt mechanism for raisingand lowe...
Page 9 - CARE AND CLEANING; NOTE; CLEANING INSTRUCTIONS
6 CARE AND CLEANING Your skillet must be cleaned regularly to maintain itsfast, efficient cooking performance, and to ensure itscontinued safe, reliable operation. WARNING: Do not use chloride base detergents. There is a growing numberof non-chloride cleaners available. Ifunsure of the cleaners chlo...
Page 10 - FAUCET ASSEMBLY; ITEM PART DESCRIPTION; SERVICE PARTS; WARRANTY
7 FAUCET ASSEMBLY ITEM PART DESCRIPTION QTY. NO. NO. 1. KE50825-7 3/4" SPOUT . . . . . . . . . . . . . . . . . . . . . . . .1 2. FA95022 RETAINING RING . . . . . . . . . . . . . . . . . . . .1 3. FA05002-19 "O" RING . . . . . . . . . . . . . . . . . . . . . . . . . . .1 4. KE51736 LONG F...
Page 11 - PAN MOUNT ASSEMBLY; ITEM PART
8 PAN MOUNT ASSEMBLY ITEM PART DESCRIPTION QTY. NO. NO. 1. HEATING ELEMENTS . . . . . . . . . . . .6 3 30 0 G GA AL LL LO ON N SK50845-1 ELEMENT, 2.00 KW, 480 VAC SK50845-2 ELEMENT, 2.67 KW, 416 VAC SK50845-3 ELEMENT, 2.00 KW, 416 VAC SK50845-4 ELEMENT, 2.67 KW, 240 VAC ELEMENT, 2.00 KW, 208 VAC SK5...
Page 12 - TILT COMPONENTS
9 ITEM NO. PART NO. DESCRIPTION QTY. 1. KE51730 TILT SHAFT BEARING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. FA31010 LOCK WASHER, 3/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3. FA20030 HEX NUT, 3...
Page 18 - Any maintenance or service involving disassembly of components; LUBRICATION PROCEDURE; TRUNNIONS; HINGE ADJUSTMENT INSTRUCTIONS; MAINTENANCE
15 WARNING : Any maintenance or service involving disassembly of components should be made by a qualified service technician. Ensure electrical and water supply (if applicable) to the unit are shut off. ! LUBRICATION PROCEDURE Lubricate the following parts every three months to insure smooth operati...
Page 19 - SEQUENCE OF OPERATIONS
16 SEQUENCE OF OPERATIONS When using these instructions refer to the SEL-TI wiringschematic. 1. Supply Voltage is sent to the primary of the 120VAC transformer. 2. Supply voltage is sent to the normally open con-tacts of the Heat Contactors, C 1 and C2. 3. 120 VAC is sent from the secondary of the 1...
Page 20 - SPARE PARTS LIST
17 PART NO. DESCRIPTION QTY. H HE EA AT TIIN NG G E EL LE EM ME EN NT TS S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 30 GALLON SK50845-1 ELEMENT, 2.00 KW, 480 VAC SK50845-2 ELEMENT...
Page 21 - WIRING DIAGRAM
18 WIRING DIAGRAM RESISTOR ELECTRICAL COMPONENTPART #s FUSE 3A KE52936-6 10 FUSE 1.25A KE52936-8 10 RELAY 1 SK2475500 12 HEATING ELEMENTS - SEE "PAN MOUNT ASSEMBLY" ON PAGE # 8 ON/OFF SWITCH SK2474103 11 HIGH LIMIT KE55069-7 8 THERMOSTAT SK2142002 11 SENSOR SK50933-1 8 HEAT INDICATOR SK50905...
Page 22 - Symbol Legend
19 19 ONMARCHEENCENDIDOACCESOAN PAUSE, INTERRUPTIONPAUSE, INTERRUPTIONPAUSA, INTERRUPCIONPAUSA, INTERRUZIONEPAUSE, UNTERBRECHUNG RESETRÉENCLENCHERRECONECTARRESETNULLSTELLEN STOP OF ACTIONARRÊT DE L'ACTIONPARAR FUNCIONAMIENTOARRESTO OPERAZIONEFUNKTION STOPPEN FAST STOP, EMERGENCYARRÊT RAPIDE D'URGENC...