Page 2 - SPEciFicATiONS; without oil WiLL ruin the engine and void the warranty.; SAVE ThiS MANuAL
Page 2 SKU 98452 For technical questions, please call 1-800-444-3353. SPEciFicATiONS VAC Electrical Specifications 115 Volts @ 20 Amps Current Output 60 Hz 2200 Rated Watts / 2400 Max Watts Two 120V, Household Receptacles with a 20 Amp circuit breaker VDC Electrical Specifications 12 VDC @ 10 Amps C...
Page 3 - READ AND uNDERSTAND ALL iNSTRucTiONS; WORK AREA; Keep your work area clean and well lit.; ELEcTRicAL SAFETY
Page 3 SKU 98452 For technical questions, please call 1-800-444-3353. uNPAcKiNG When unpacking, check to make sure all the parts shown on the Parts LIsts on pages 20 and 22 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of the manu...
Page 4 - or moving parts. Replace damaged Power cords immediately.; PERSONAL SAFETY; Do not overreach. Keep proper footing and balance at all times.; GENERATOR uSE AND cARE
Page 4 SKU 98452 For technical questions, please call 1-800-444-3353. Do not abuse the Power cords. Never use a Power cord to carry tools or pull 8. the Plug from the outlet. Keep Power cords away from heat, oil, sharp edges, or moving parts. Replace damaged Power cords immediately. Damaged Power Co...
Page 5 - and efficiently powered by a portable generator.; SERVicE; and debris from getting into the fuel tank.
Page 5 SKU 98452 For technical questions, please call 1-800-444-3353. the generator. Such preventive safety measures reduce the risk of starting the generator accidentally. Store idle generators out of reach of children and other untrained persons. 19. Generators are dangerous in the hands of untrai...
Page 6 - Maintain labels and nameplates on the Generator and Engine.; These carry; tions in the; a risk of electric shock or injury.
Page 6 SKU 98452 For technical questions, please call 1-800-444-3353. Maintain labels and nameplates on the Generator and Engine. 25. These carry important information. If unreadable, or missing, contact Harbor Freight Tools for a replacement. Generator service must be performed only by qualified re...
Page 7 - SPEciFic SAFETY RuLES AND PREcAuTiONS; hEART PAcEMAKER PREcAuTiON; tor only in a well ventilated outdoor areas. carbon monoxide fumes; Pipes and silencer should not use any flammable materials, nor; safely hold the weight of the Generator.; If the floor/ground surface is not level,
Page 7 SKU 98452 For technical questions, please call 1-800-444-3353. SPEciFic SAFETY RuLES AND PREcAuTiONS hEART PAcEMAKER PREcAuTiON WARNiNG! People with pacemakers should consult their physician(s) before using this product. Electromagnetic fields in close proximity to a heart pacemaker could cau...
Page 8 - avoid trapping moisture with the Generator’s area.; FiRE AND EXPLOSiON PREcAuTiONS; Gasoline fuel and fumes are flammable, and potentially explosive.
Page 8 SKU 98452 For technical questions, please call 1-800-444-3353. Install sound and weather proofing only when it is not raining or snowing to 11. avoid trapping moisture with the Generator’s area. FiRE AND EXPLOSiON PREcAuTiONS Gasoline fuel and fumes are flammable, and potentially explosive. 1...
Page 9 - MEchANicAL PREcAuTiONS; ALWAYS; Disconnect; check for damaged parts.; Before using the Generator, any part that appears; Do not operate the Generator with safety guards removed.; chEMicAL PREcAuTiONS; eye contact, immediately flush eyes with clean water.
Page 9 SKU 98452 For technical questions, please call 1-800-444-3353. MEchANicAL PREcAuTiONS ALWAYS 1. make sure the Power Switch is in its “OFF” position. Disconnect the spark plug wire, and allow the Engine to completely cool before carrying our maintenance. check for damaged parts. 2. Before usin...
Page 10 - NOiSE PREcAuTiON; Always; Generator when it is running.; ELEcTRicAL PREcAuTiONS; ment from its power input.; TABLE A
Page 10 SKU 98452 For technical questions, please call 1-800-444-3353. NOiSE PREcAuTiON Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the Generator when it is running. ELEcTRicAL PREcAuTiONS All conn...
Page 11 - Keep all electrical equipment clean and dry.; Replace any wiring where the in-; insulate all connections and disconnected wires.; Prevent body contact with grounded surfaces such; iNSTALLATiON; NOTE; : The Generator weighs 103.6 pounds. Use care and the proper lifting; GENERAL LOcATiONS
Page 11 SKU 98452 For technical questions, please call 1-800-444-3353. Keep all electrical equipment clean and dry. 8. Replace any wiring where the in- sulation is cracked, cut, abraded, or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight. ...
Page 12 - ThiS uNiT cAN POWER ThE FOLLOWiNG iTEMS; iTEM
Page 12 SKU 98452 For technical questions, please call 1-800-444-3353. GENERATOR SuPPORT AND MOuNTiNG Mount the Generator on a concrete slab capable of supporting the weight of the Gen- erator. The slab must extend on all sides beyond the Frame (41B) by a least one foot. Contact a cement contractor ...
Page 13 - Ac Applications; for electrical shock.; OPERATiNG iNSTRucTiONS; Assembly Diagrams on pages 21 and 23.; “OFF”; position.
Page 13 SKU 98452 For technical questions, please call 1-800-444-3353. Ac Applications Before connecting an appliance or power cord to the generator: Make sure that it 1. is in good working order. Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to...
Page 15 - unleaded; Fuel Tank with unleaded gasoline.; ON
Page 15 SKU 98452 For technical questions, please call 1-800-444-3353. Before the first use, remove the Fuel Tank Cap (33B 3. 1 ) and fill the Fuel Tank (30B 1 ) with unleaded gasoline. Then, replace the Fuel Tank Cap. If necessary, refill the Fuel Tank with unleaded gasoline. (See Figure c.) To Sta...
Page 17 - Powering 120 Volt AC Tools and Equipment:; Powering 12 Volt DC Tools and Equipment:
Page 17 SKU 98452 For technical questions, please call 1-800-444-3353. Powering 120 Volt AC Tools and Equipment: Prior to powering tools and equipment, make sure the Generator’s rated voltage, 1. and amperage capacity (115 VAc / 20 AMPs) is adequate to supply all electrical loads that the unit will ...
Page 19 - Do not use damaged equipment.; Follow all maintenance procedures as outlined in the; Engine Maintenance Schedule; drain the old
Page 19 SKU 98452 For technical questions, please call 1-800-444-3353. REV 09a iNSPEcTiON, MAiNTENANcE, AND cLEANiNG cAuTiON! Always make sure the Engine Power Switch (2) is in its “OFF” position. 1. Disconnect the spark plug wire from the engine and allow sufficient time for the Engine and Generato...
Page 20 - PARTS LiST; available individually as replacement parts.; PLEASE READ ThE FOLLOWiNG cAREFuLLY
Page 20 SKU 98452 For technical questions, please call 1-800-444-3353. PARTS LiST Part Description Qty 1 Bolt (M6 x 12) w/Lock Washer 9 2 Engine Power Switch 1 3B Control Panel 1 4 Voltmeter 1 5 Circuit Breaker 1 6 Outlet 2 7 DC Terminal 2 8 Ground Connector 1 9 DC Fuse 1 10 Pilot Light 1 11 Shock A...
Page 21 - ASSEMBLY DiAGRAM
Page 21 SKU 98452 For technical questions, please call 1-800-444-3353. ASSEMBLY DiAGRAM
Page 22 - PARTS LiST - cONTiNuED
Page 22 SKU 98452 For technical questions, please call 1-800-444-3353. PARTS LiST - cONTiNuED Part Description Qty 1A Muffler 1 2A Cylinder Head Bolt 4 3A Cylinder Head Cover Bolt 4 4A Cylinder Head Cover 1 5A Lock Nut 2 6A Adjusting Screw 2 7A Rocker Arm 3 8A Rocker Arm Bolt 2 9A Valve Push Rod Gui...
Page 24 - Manufacturer’s Warranty coverage; Owner’s Warranty Responsibilities; Emission control System Warranty; LiMiTED 1 YEAR WARRANTY
Page 24 SKU 98452 For technical questions, please call 1-800-444-3353. california and united States Emission control Defects Warranty Statement The California Air Resources Board (herein CARB), the United States Environmental Protection Agency (herein EPA), and Harbor Freight Tools ® (herein HFT) ar...