Page 2 - Have questions or need assistance?; Call our Customer Care Team Toll-Free at:; AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover. WARNING: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Have questions...
Page 3 - PORTABLE GENERATOR; TABLE Of CONTENTS
41534 9500 Starting Watts / 7500 Rated Watts PORTABLE GENERATOR TABLE Of CONTENTS Introduction 1 Introduction 1 Portable Power Generator 1 Accessories 1 This Booklet 1 Manual Conventions 2 Safety Rules 3 Controls and Features 5 Generator 5 Power Panel 6 Parts Included 7 Wheel Kit 7 Other 7 Assembly ...
Page 4 - ENGLISH; Introduction; Model Number; INTRODUCTION
1 REV 41534-20140124 ENGLISH 41534 Introduction Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service. Portable Power Generator This ...
Page 5 - MANUAL CONVENTIONS; CAUTION; DANGER; WARNING
REV 41534-20140124 2 41534 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.Follow all safety messages to...
Page 6 - SAfETy RULES; When servicing the generator:
3 REV 41534-20140124 ENGLISH 41534 SAfETy RULES Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. Operate generator outdoors only ...
Page 7 - When adding or removing fuel :
REV 41534-20140124 4 41534 ENGLISH SAfETy RULES Improper treatment or use of the generator can damage it, shorten its life and void your warranty. Use the generator only for intended uses.Operate only on level surfaces.DO NOT expose generator to excessive moisture, dust, or dirt.DO NOT allow any mat...
Page 8 - Generator; CONTROLS AND fEATURES
5 REV 41534-20140124 ENGLISH 41534 Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. (1) Fuel Tank – 5.9 gallon (22.4 L) capacity fuel tank. (2) Choke – Controls choke val...
Page 9 - Power Panel
REV 41534-20140124 6 41534 ENGLISH Power Panel 3 CONTROLS AND fEATURES 1 2 4 6 5 8 7 (1) Ignition Switch – Used to start or stop the generator. (2) 120/240 Volt AC, 30 Amp Twist-Lock Receptacle (NEMA L14-30R) – May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Am...
Page 10 - Parts Included; Wheel Kit
7 REV 41534-20140124 ENGLISH 41534 Parts Included Your 41534 Gasoline Powered Generator ships with the following parts: Wheel Kit – 10 in. Wheel 2 – Flange Bolt (M10x120 for Wheel) 2 – Bushing 2 – Flat Washer Ø10 2 – Nut (M10) 2 – Support Leg w/ Vibration Mounts 1 – Flange Bolt (M8x16 for Support Le...
Page 11 - ASSEMBLy; Remove the Generator from the Shipping Carton; Install the Wheel Kit; Connect the Battery
REV 41534-20140124 8 41534 ENGLISH ASSEMBLy Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. P...
Page 12 - NOTE; Add Engine Oil; Add Engine Oil Cont’d.
9 REV 41534-20140124 ENGLISH 41534 ASSEMBLy 1. Place the generator on a flat, level surface. 2. Remove oil fill cap /dipstick to add oil.3. Add up to 1.2 qt. (1.1 L) of oil (included) and replace oil fill cap/dipstick. DO NOT OVERFILL. 4. Check engine oil level daily and add as needed. The recommend...
Page 13 - Grounding; Add fuel
REV 41534-20140124 10 41534 ENGLISH ASSEMBLy Add fuel Cont’d. Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided on the power panel. For remote grounding, connect of ...
Page 14 - OPERATION; Generator Location; Surge Protection
11 REV 41534-20140124 ENGLISH 41534 OPERATION Generator Location NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some...
Page 15 - Connecting Electrical Loads; Stopping the Engine
REV 41534-20140124 12 41534 ENGLISH Connecting Electrical Loads 1. Let the engine stabilize and warm up for a few minutes after starting 2. Plug in and turn on the desired 120/240 Volt AC single phase, 60 Hz electrical loads. – DO NOT connect 3-phase loads to the generator. – DO NOT connect 50 Hz lo...
Page 16 - Do Not Overload Generator; Capacity; Power Management
13 REV 41534-20140124 ENGLISH 41534 OPERATION Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes. 1. Select the electrical devices you plan on running at the same time. 2. Total the running watts of these items. This i...
Page 17 - MAINTENANCE AND STORAGE; Air filter; Engine Maintenance; Oil
REV 41534-20140124 14 41534 ENGLISH MAINTENANCE AND STORAGE The owner/operator is responsible for all periodic maintenance. Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator. Never operate a damaged or defective generator. Tampering with the fact...
Page 18 - Adjustments; Spark Arrester; Generator Maintenance
15 REV 41534-20140124 ENGLISH 41534 MAINTENANCE AND STORAGE Adjustments The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at1-877-338-0999 for all oth...
Page 19 - Storage; Generator Storage; Battery; Disconnect the Battery; Charge the Battery
REV 41534-20140124 16 41534 ENGLISH MAINTENANCE AND STORAGE Storage The generator should be started at least once every 14 days and allowed to run for at least 20 minutes. For longer term storage, please follow these guidelines. Generator Storage 1. Add a properly formulated fuel stabilizer to the t...
Page 20 - SPECIfICATIONS
17 REV 41534-20140124 ENGLISH 41534 SPECIfICATIONS fuel Fuel capacity is 5.9 gallons (22.4 L). Use regular unleaded gasoline with a minimum octane rating of 85 and an ethanol content of less than 10% by volume. Generator Specifications – Model 41534 – Rated Wattage 7500 Watts – Starting Wattage 9500...
Page 21 - Wiring Diagram
REV 41534-20140124 18 41534 ENGLISH SPECIfICATIONS Wiring Diagram
Page 22 - Parts Diagram
19 REV 41534-20140124 ENGLISH 41534 SPECIfICATIONS Parts Diagram 1 2 3 4 5 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 38 43 44 45 37 38 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 6465 66 67 68 69 70 72 73 74 75 76 77 78 79 80 81 82...
Page 23 - Parts List
REV 41534-20140124 20 41534 ENGLISH Parts List # Part Number Description Qty 1 2.06.006 Clamp (Ø7× Ø1) 3 2 152.070013.01 Pipe, Air Cleaner 1 3 2.05.001 Clamp (Ø8 ×6.5) 2 4 152.070014.03 Pipe, Reversal Valve 830 mm 1 5 1.16674.0812 Flange Bolt M8 ×12 2 6 152.070702.03 Support Arm, Top 1 7 152.070018....
Page 24 - Engine Parts Diagram
21 REV 41534-20140124 ENGLISH 41534 Engine Parts Diagram SPECIfICATIONS 45 64 40 10 2 10 3 10 4 10 5 91 10 6 10 7 11 0 10 9 10 8 85 10 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 16 24 25 26 27 28 29 30 31 33 34 35 12 36 30 37 38 23 39 41 42 43 44 46 47 48 49 50 51 52 53 12 54 55 57 58 59 60 61 ...
Page 26 - TROUBLESHOOTING; for further technical support :
23 REV 41534-20140124 ENGLISH 41534 TROUBLESHOOTING for further technical support : Technical ServiceMon – Fri 8:30 AM – 5:00 PM (PST/PDT)Toll Free: 1-877-338-0999tech@ championpowerequipment.com Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Un...
Page 27 - WARRANTy; Installation, Use and Maintenance Cont’d.
REV 41534-20140124 24 41534 ENGLISH WARRANTy WARRANT y CHAMPION POWER EQUIPMENT 2 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locatio...