Page 2 - Page; Table of Contents
Page Introduction ..................................................................................................... 3 Safety Information ..................................................................................... 3 System Requirements ......................................................
Page 3 - Voice service in the event of a short disruption to your; Safety Information; CAUTION; • Internal battery voltage is 12V DC.; System Requirements; The RG Battery Backup is designed for use with the AT&T U-verse; Residential Gateway and your AT&T U-verse; Introduction
2 3 22 Thank you for purchasing the Residential Gateway (RG) Battery Backup. Natural and man-made power disturbances can disrupt the power supplied to your home electronics. These power problems can disrupt the normal operation of important electrical equipment and related services. Battery Backups ...
Page 4 - You should have received the following:; – RG Battery Backup unit (12V sealed lead battery included)
3 3 4 Recycling UNIT CONTAINS SEALED LEAD BATTERY. BATTERY SHOULD BE RECYCLED. Belkin International, Inc., advocates sound environmental management of used batteries. For battery-replacement and recycling information, please call us at 866-539-5791, or visit our website at www.belkin.com/gatewaybatt...
Page 5 - Product Layout and Function; Residential; Status Indicators
5 4 5 Product Layout and Function 1 Power on/off Power on/off switch is located on the back panel. Use this switch to turn the RG Battery Backup on/off. The unit will not supply power to the AT&T U-verse SM Residential Gateway when power switch is in OFF position. 2 Status Indicators Three LED s...
Page 6 - Residential Gateway
Residential Gateway (RG) Battery Backup 5 REV 082007 P75319-B BU3DC000-12V 5 Belkin Tech Support US: 866-539-5791 UK: 0845 607 77 87 Australia: 1800 235 546 New Zealand: 0800 235 546 Singapore: 800 616 1790 Europe: www.belkin.com/support Belkin International, Inc. 501 West Walnut Street Los Angeles,...
Page 7 - Audible and Visual Alarms; The RG Battery Backup alarms to indicate certain events.; Audible alarm will not sound when mute switch is in ON position.
6 Audible and Visual Alarms The RG Battery Backup alarms to indicate certain events. Front-Panel Label Visual Indicator Audible Alarm Description ON A/C Green LED lights None The RG Battery Backup is operating on A/C. Testing Battery Green LED flashes None The RG Battery Backup is conduct-ing a self-...
Page 8 - Installation; Voice service, including 911 dialing, will
6 7 Installation NOTE: Before installation, please inspect the RG Battery Backup. Make sure that nothing inside the package is damaged. The RG Battery Backup must be installed near the Residential Gateway and be easily accessible. NOTE: It takes approximately 18 hours to charge a new, fully depleted...
Page 9 - • Turning off the RG Battery Backup; Turn switch to OFF position. The “ON A/C” LED light should turn off.; • To Silence Audible Alarm; Operation
8 7 8 • Turning off the RG Battery Backup Turn switch to OFF position. The “ON A/C” LED light should turn off. • To Silence Audible Alarm Turn mute switch to ON (down) position. • To Conduct a Self-Test Use the self-test to verify both the operation of the RG Battery Backup and the condition of the ...
Page 10 - Mounting holes
9 8 9 Wall-Mounting Instructions (Optional) NOTE: Required hardware not included. Refer to the wall-mount instructions for required tools and materials. STEP 1: Position the template on the wall where you want to mount the RG Battery Backup and tape in place. STEP 2: Make a mark on the wall in the 2...
Page 11 - Battery-Replacement Procedure; Securely reconnect battery door.
9 Battery-Replacement Procedure The RG Battery Backup is designed with an easy-access battery door. Replacement of the battery requires removing the battery door on the rear of the device. No tools are needed. STEP 1:Turn off power switch. Disconnect the RG Battery Backup from power and any connecte...
Page 12 - Technical Specifications; Technical Specifications:
11 Technical Specifications Technical Specifications: Input Voltage Range 0 to 150VAC Input Frequency 50/60Hz Nominal Output Voltage 13.7VDC – On A/C Mode Nominal Output Voltage 12VDC – On Battery Mode Max Power 30W Cold-Start Functionality Included Output Transfer < 1ns Surge Protection Included...