Page 2 - Warranty Information; REPLACEMENT PARTS
Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the original purchaser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship. Written notice of a claim under this warranty must be received by the...
Page 3 - Table of Contents
Gas Pressure Fryer Table of Contents 1 Table of Contents Table of Contents .................................................................................................................................................... 1 Introduction ................................................................
Page 4 - Introduction; PERFECTION IN PRESSURE FRYING!; Safety
Gas Pressure Fryer Introduction 2 Introduction The LGF Pressure Fryer is compact, attractive and functional in design. It is constructed of a stainless steel fryer pot for cleaning ease. Exclusive BKI patented features and safety devices offer flexibility, efficiency and reliability plus PERFECTION ...
Page 5 - Specific Precautions; Equipotential ground plane
Gas Pressure Fryer Introduction 3 Specific Precautions Lids for LGF Pressure Fryers manufactured prior to May 27, 1980 (or units with serial numbers lower than 3613) could be manually opened while under pressure resulting in serious injury or death. If you have one of these units, please contact the...
Page 6 - Safe Work Practices; Beware of High Voltage; Keep The Area Around Your Fryer Uncluttered
Gas Pressure Fryer Introduction 4 Safe Work Practices Do Not Store Or Use Anything Flammable Near The Fryer Your pressure fryer is powered by either natural gas or LP gas. Do not store or use gasoline or any flammable liquids or vapors near this or any other appliance. Flammable materials will burn ...
Page 7 - Keep The Casters Locked
Gas Pressure Fryer Introduction 5 Keep The Floor Around Your Fryer Clean Of Shortening Make sure to keep the floor around your fryer clean of shortening and other liquids. Serious injury can occur if you slip near your fryer. You could be burned by hot shortening that splashes out of the fryer or by...
Page 8 - Do Not Over-Tighten The Spin Handle; Seal The Safety Valve Properly
Gas Pressure Fryer Introduction 6 Always Make Sure The Lid Hook Is Latched When Closing The Fryer To make sure the lid hook is latched properly, press down the lid until the hook snaps shut. Hot shortening and steam can escape if the lid hook is not latched properly. You could be burned. Always Tigh...
Page 9 - Keep Away From The Vent; Protect Children
Gas Pressure Fryer Introduction 7 Keep Away From The Vent Hot steam escapes from the vent continuously when you are using your fryer. You could be burned if you get too close to the vent. Keep this manual with the Equipment This manual is an important part of your equipment. Always keep it near for ...
Page 10 - Be Prepared for Emergencies; Do Not Smoke Near The Fryer.
Gas Pressure Fryer Introduction 8 Be Prepared for Emergencies Be prepared for fires, injuries, or other emergencies. Keep a first aid kit and a fire extinguisher near the equipment. You must use a 40-pound Type BC fire extinguisher and keep it within 25 feet of your equipment. Keep emergency numbers...
Page 11 - Safety Labels
Page 13 - Installation
Gas Pressure Fryer Installation 11 Installation For installation information, refer to Gas Pressure Fryer, MODELS LGF, LGF-F, & LGF-FC, Installation and Operation Manual LI0101 .
Page 14 - Operation; Controls and Indicators
Gas Pressure Fryer Operation 12 Operation Controls and Indicators Refer to the figure and table below for an explanation of the fryer’s controls and indicators.
Page 15 - Item Description
Gas Pressure Fryer Operation 13 Item Description Function 1 Pressure Gauge Indicates the pressure inside the pot. 2 Spin Handle Used to tighten the lid to the pot once it is latched. 3 Pop Safety Valve lever Used to release pressure periodically to prevent the seat from sticking. 4 Computer Used to ...
Page 17 - Care of the Shortening; LGF and LGF-F Operation
Gas Pressure Fryer Operation 15 Care of the Shortening Solid shortening should always be returned to the filter vat while in the liquid state. If this is not done, it will have to be heated to a liquid state. When using solid shortening, the fryer must be equipped with a pump heater. After filtering...
Page 19 - OFF
Gas Pressure Fryer Operation 17 2. When frying chicken, connect the basket handle and lower the basket into the shortening in the fryer pot. Hot shortening may splash out of the pot causing severe injury when dropping chicken into pot. Carefully drop pieces of chicken into pot to prevent shortening ...
Page 20 - System Programming
Gas Pressure Fryer Operation 18 LGF-FC Operation System Programming Use the following figure and table to set options that apply to each product programs. Figure 1. System Programming Sequence
Page 21 - STEP ACTION
Gas Pressure Fryer Operation 19 Table 1. System Programming Procedure STEP ACTION DISPLAY COMMENTS 1 Press the FILTER/OFF/FRY switch to FRY . LOW 2 Press PROG on the keypad. PROGRAM CODE 3 Input 1712 and ENTER. PROGRAM SYSTEM 4 Press ENTER. PROGRAM DEGREES ° F This command allows you to choose the t...
Page 22 - Product Programming
Gas Pressure Fryer Operation 20 Product Programming Use the following figure and table to set a maximum of eight product programs. The product programs must be set before cooking can begin. Figure 2. Product Programming Sequence
Page 26 - COOK
Gas Pressure Fryer Operation 24 4. Carefully drop the chicken in the shortening one piece at a time starting with thighs and drumsticks. The fryer is designed to accommodate 32 pieces of chicken. Failure to use the insulated mitts will result in severe injury. Always use the insulated mitts when han...
Page 27 - Recipes
Gas Pressure Fryer Operation 25 Recipes Fried Onion Rings 1. Take frozen onion rings from freezer or bread fresh onion rings with Imperial breading. 2. Place onion rings into fryer basket. 3. Close cover to begin pressure frying. 4. Cook for 4 minutes at 350°F for frozen product. OR 5. Cook for 3 mi...
Page 29 - Operation After Gas or Power Outage; Normal Shutoff
Gas Pressure Fryer Operation 27 Operation After Gas or Power Outage The fryer may shut off automatically if the gas supply is interrupted or the power goes out. If either of these conditions occur you should perform the following procedure: For your safety, if the gas supply stops, or, if the power ...
Page 30 - Maintenance
Gas Pressure Fryer Maintenance 28 Maintenance For maintenance information, refer to Gas Pressure Fryer, MODELS LGF, LGF-F, & LGF-FC, Installation and Operation Manual LI0101 .
Page 31 - Replacement Parts; Assemblies; Description
Gas Pressure Fryer Replacement Parts 29 Replacement Parts Use the information in this section to identify replacement parts. To order replacement parts, call your local BKI sales and service representative. Before calling, please note the serial number, model number and voltage on the rating tag aff...
Page 36 - QTY
Gas Pressure Fryer Replacement Parts 34 Table 3. Lid/Arm Assembly (AN3211350S) Parts ITEM # PART # QTY DESCRIPTION Figure 3 (sheet 1) AN3211350S LID/ARM ASSY Figure 3 (sheet 2) H0157 1 HANDLE, SPIN FOR FRYERS 1 FT0332 3 STUD, 5.5” TIGHTEN DN HN 2 K0003 2 KNOB, BLACK #85C 3 K0020 1 HUB, TIGHTEN DOWN ...
Page 52 - Accessories
Gas Pressure Fryer Replacement Parts 50 Accessories Description Accessory # Figure # Item # BASKET, LGF B0108B Figure 15 1 HANDLE, TEE STYLE LIFT H0151 Figure 15 2 BRUSH, DRAIN (LONG WHITE) B0075 Figure 15 3 BRUSH, LONG #5702 B0051 Figure 15 4 BRUSH, POT SCRUBBER, WHITE B0049 Figure 15 5 BRUSH, SHOR...
Page 53 - Components
Gas Pressure Fryer Replacement Parts 51 Components Description Component # Figure # Item # ARM ADJUSTABLE STOP /FKM A0101 Figure 16 1 CASTER, 2470-DIK-075-R05/22 C0409 Figure 16 2 CASTER, 2477-DIK-075-R05/22 C0410 Figure 16 3 FILTER BAG CLIP FI0007 ST0015 Figure 16 4 FILTER, FKM-F 13.5 X 20.5 FI0007...
Page 54 - Wiring Diagrams; Wiring Diagram
Gas Pressure Fryer Wiring Diagrams 52 Wiring Diagrams Refer to the table below to find the wiring diagram associated with your unit. Wiring Diagram Diagram # Figure # Page # LGF-F 120V/60HZ/1 Phase SB322901 Figure 17 53 LGF-FC 120V/60HZ/1 Phase LGFE1034 Figure 18 54 LGF-FC 220V/50HZ/1 Phase LGFE1038...