Page 2 - Warranty Information
Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the original purchaser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship. Written notice of a claim under this warranty must be received by the...
Page 3 - Table of Contents
Ventless Hood System Table of Contents 1 Table of Contents Table of Contents ........................................................................................................................................ 1 Introduction ..........................................................................
Page 4 - Introduction; Safety Precautions
Ventless Hood System Introduction 2 Introduction Congratulations! You have chosen BKI ’s Ventless Hood system, a state-of-the-art unit that filters grease laden air and returns it to the room. The BKI name and trademark on this unit assures you of the finest in design and engineering -- that it has ...
Page 5 - Specific Precautions; Safe Work Practices; Beware of High Voltage; Protect Children
Ventless Hood System Introduction 3 Specific Precautions Carbon monoxide poisoning will result from using this hood with any appliance that utilizes combustible fuel. Use only electrical appliances with this hood. In the event of an appliance fire, serious injury, property damage or death could occu...
Page 6 - Prepare for Emergencies
Ventless Hood System Introduction 4 Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your equipment. Keep all safety labels clean and in good condition. Replace any damaged or missing safety labels. If you need new safety labels, contact: BKI Technical Servi...
Page 7 - UL Information; Pressure/Open Fryers; Sandwich Grills
Ventless Hood System Introduction 5 UL Information Failure to adhere to building, fire and electrical codes during installation of this unit could result in death, serious injury or property damage. The authority having jurisdiction, such as the local building inspector or fire marshal, should be co...
Page 8 - Fryers Specifications
Ventless Hood System Introduction 6 Fryers Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 60 Maximum Input 22 KW (3ph) 14.4 KW (1ph) Frequency 60 Hz Maximum normal frying temperature 375 ° F. (191 ° C.) Maximum shortening capacity 110 lbs. (50kg.) Maximum cooking surface area 396 sq. in. (25...
Page 9 - Operation; Principle of Operation
Ventless Hood System Operation 7 Operation Principle of Operation A blower inside the ventless hood draws cooking vapors through a grease baffle. Inside the baffle, the air reverses direction two times capturing particles of moisture, grease, and dirt. Material collecting on the baffle drains into t...
Page 10 - When to Replace the Filter
Ventless Hood System Operation 8 Shut-Down Power to the appliance is turned off, when the hood is turned off. For proper operation, always turn off appliance and allow time for it to cool before turning off the filter hood. This will insure proper capture of grease vapors. To stop the Filter Hood, p...
Page 11 - Installation; Unpacking and Handling; Location and Clearance
Ventless Hood System Installation 9 Installation Unpacking and Handling Inspection for Shipping Damage YOU are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage to cartons or pallets is found, or if a...
Page 12 - Leveling
Ventless Hood System Installation 10 Leveling 1. Adjust the four feet provided on the bottom of the unit so there is a minimum of 6” clearance below the frame side members (NSF/UL REQUIREMENTS). 2. Check for level from side to side and front to back using a 4’ level placed appropriately on the frame...
Page 13 - Securing
Ventless Hood System Installation 11 Securing Wall Mount After the hood has been located and leveled, secure to building by utilizing the .437 diameter holes provided in the rear of the fire extinguisher cylinder shelf (Refer to figure below). Using 1/4” lag screw(s), spacer(s) (if required), and an...
Page 14 - Assembly and Mounting; Air Deflector
Ventless Hood System Installation 12 Assembly and Mounting Fire Damper A UL Listed 165 ° F fusible link must be installed in the damper assembly located at the top of the unit. Install as follows: 1. Lift the damper. 2. Place the link on the damper hook. 3. Lower the damper while placing the link on...
Page 15 - Particle/Odor Filter; Appliance Stop FB37144203 (Used with BKI Automatic Lift Fryers)
Ventless Hood System Installation 13 Particle/Odor Filter 1. Remove the filter from the plastic bag. 2. Open the filter door on the front of the unit by rotating the handle counter-clockwise. 3. Observing the “UP” arrows on the filter, with a hand at each front corner, carefully slide the filter int...
Page 16 - Appliance Restraining Device
Ventless Hood System Installation 14 Appliance Restraining Device Install appliance-restraining device as shown in the figure below. In the event of an appliance fire, serious injury, property damage or death could occur if the appliance is not secured to the hood. A restraining device has been prov...
Page 17 - Fire Extinguishing System
Ventless Hood System Installation 15 Fire Extinguishing System In the event of an appliance fire, serious injury, property damage or death could occur if any part of the appliance obstructs the spray nozzles. Ensure that lids and/or other parts of the appliance do not obstruct the spray pattern of e...
Page 18 - Wiring
Ventless Hood System Installation 16 3. If required, connect the provided fire extinguishing system contacts for remote signaling (refer to the electrical diagram in this manual). 4. Adjust the position of the two ADP appliance nozzles as depicted below. 5. Reset control head. With control head NOT ...
Page 19 - Standard Electrical Connection
Ventless Hood System Installation 17 The fire extinguishing system must be operative before the electrical system will function. Refer to the electrical diagram included in attached to this unit or in the service manual. Standard Electrical Connection This connection is for UL listed appliances supp...
Page 21 - Appliance Electrical Connection
Ventless Hood System Installation 19 Appliance Electrical Connection This connection is for appliances requiring a UL listed flexible conduit connections (refer to figure below). 1. Remove receptacle and four wires (T1, T2, T3, and Ground). 2. Cover junction box hole with provided plate and hardware...
Page 22 - Maintenance; Scheduled Maintenance
Ventless Hood System Maintenance 20 Maintenance Electrocution could occur if this unit is hosed down with water. This unit is NOT designed for hose wash-down cleaning! Refer to scheduled maintenance below for proper hood cleaning. Electrocution could occur if power is not removed from this unit befo...
Page 23 - Cleaning the Grease Baffle; Replacing the Particle/Odor Filter
Ventless Hood System Maintenance 21 Cleaning the Grease Baffle 1. Shut down the unit. 2. Locate the thumbscrews and retaining frame at the top of the grease baffle. 3. With one hand, hold the baffle to prevent it from dropping. With the other hand, loosen the thumbscrews and slide the retaining fram...