Page 2 - TABLE OF CONTENTS; SECTION
2 TABLE OF CONTENTS DELIVERY & FREIGHT CLAIMS 3 Label Locations 5 TROUBLESHOOTING WIRING DIAGRAMS WARRANTY DELIVERY 3 Review of Received Goods 3 FREIGHT CLAIMS 3 Inspection 3 3 4 Recognize Safety Information 4 Understand Signal Words 4 Avoid Injury 4 Emergency Preparation 4 Follow Safety Instruc...
Page 3 - DELIVERY AND FREIGHT CLAIMS; DELIVERY
3 DELIVERY AND FREIGHT CLAIMS DELIVERY REVIEW OF RECEIVED GOODS: FREIGHT CLAIMS INSPECTION: 1. Observe shipping carton for obvious shipping damage. 2. Note concerns while delivery party is present (see freight claims). 3. Unpack the unit and inspect for shipping damage. Notify manufacturer immediate...
Page 4 - WARNING LABELS AND SAFETY INSTRUCTIONS; AV O I D I N J U R Y F R O M H I G H V O LTA G E
4 Hazardous voltage. Can shock, burn or kill. Turn power off Unplug power cord before Servicing or cleaning. Hazardous voltage. Can shock, burn or kill. Unit must be grounded to prevent injury. Check ground pin on plug. Do not use if pin is bent or RECOGNIZE SAFETY INFORMATION This is the safety ale...
Page 5 - FOLLOW SAFETY INSTRUCTIONS; good condition. Replace any missing or damaged safety signs.; SAFETY AND WARNING LABELS
5 FOLLOW SAFETY INSTRUCTIONS Carefully read all safety messages in this manual and safety signs on your equipment. Keep safety signs in good condition. Replace any missing or damaged safety signs. Learn how to operate the equipment and how to use the controls properly. Do not let anyone operate with...
Page 6 - LOCATION
6 ELECTRICAL RATING For models equipped with 120V, 60HZ, 1PH ELECTRICAL CONNECTION: The cabinet heating unit has a 2000-watt heating element and requires a 20-amp circuit. If required circuit is not available, wiring should be performed by a qualified and certified electrician. For models equipped w...
Page 7 - TO OPERATE AS A PROOFING CABINET:; partially full. (Too much water can cause longer proofing; Plug the cord set into properly grounded three- prong; TYPICAL PROOFING PREPARATION:
7 TO OPERATE AS A HEATED (HOLDING) CABINET: ! ! ! ! Operate without pan but with the cover on.Flip power switch upward to the “On” position.Flip selector switch upward to “Heat” position.Turn the “Heating” knob to maintain desired holding temperature. TO OPERATE AS A PROOFING CABINET: DANGER: Do not...
Page 8 - CLEANING PROCEDURES; HEATER ASSEMBLY REMOVAL:
8 HEAT AND MOISTURE (SECONDARY CONTROL): Heat and/or moisture can be further controlled by sliding damper, located at top of cabinet, left or right to desired opening. CLEANING PROCEDURES LEDGE REMOVAL: ! Lift up and out of holes in ledge uprights. HEATER ASSEMBLY REMOVAL: ! ! ! Open door and allow ...
Page 9 - Grasp air tunnel and lift up and off.
9 DRIP TROUGH DRAINING AND REMOVAL: DRAINING: Open drain trough by pushing clamp tab upward. Close by pushing front of clamp inward. REMOVAL: AIR TUNNEL REMOVAL: The louvered air tunnel hangs on shoulder rivets, through tear drop slots, at back of cabinet. To remove trough: remove thumbscrews; drop ...
Page 11 - TROUBLESHOOTING
11 Problem: Probable Cause: Solution: Unit will not run (heater and fan are off) Power cord is not plugged in Plug in power cord Circuit breaker is tripped Call a licensed electrician No power at outlet Call a licensed electrician Defective power cord or switch Call a licensed service agency or a li...
Page 12 - WIRING DIAGRAM; Black
12 WIRING DIAGRAM CPH70-MP17 CLASSIC-LINE PROOFER HEATER - 120V, 60Hz, 1Ph 1. Proofing Thermostat 2. On/Off Switch 3. Mechanical Timer 4. Terminal Block 5. Fan Motor 6. Heating Element 7. Selector Switch DP 8. Heating Thermostat 9. Digital Thermometer A Supply Cord - 3 Conductor, 12 A.W.G., Type SJO...
Page 16 - BevLes
16 Phone: +1 Fax: +1 (214) 565-0976 Toll Free: +1 (800) 441-1601 Website: www.BevLes.com E-mail: [email protected] (214) 421-7366 BevLes 729 Third Avenue Dallas, TX 75226