Apple 073-0674 - Manuals
Apple 073-0674 – Manual in PDF format online.
Manuals:
Manual Apple 073-0674
Summary
Xserve Blower - 2 4. If the server is in the locked position (the yellow security LED on the front panel is on), use the Allen key that came with the server to unlock it. 5. If the cable management arm is not in use, unplug all external cables except the power cord. 6. Touch the server’s metal case ...
Xserve Blower - 3 9. Grasp the thumbscrews and slide the bottom housing forward part way to expose the two chassis levers. (Figure 2) 10. While depressing both levers, pull the bottom housing all the way forward and remove it from the rack. Figure 2 11. Place the bottom housing on a sturdy, flat sur...
Xserve Blower - 4 Removing the Installed Blower 1. Disconnect the blower cable from the drive interconnect board. (Figure 3) 2. Lift the blower straight up off its mounting pegs and remove it from the server. Figure 3 Installing the Replacement Blower 1. Install the replacement blower on the two blo...