Apple Drive Interconnect Board - Manual
Apple Drive Interconnect Board – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Figure 2; Removing the Installed Drive Interconnect Board; Hard Drives
- Page 4 – Figure 3; Grasp the drive handle, and pull the drive module out of the server.; Figure 4
- Page 5 – Xserve Drive Interconnect Board -; Blowers; Repeat steps 1 and 2 for the left blower.; Figure 5
- Page 6 – Heatsink Duct; blower, and lift the end of the duct as shown.; Figure 6
- Page 7 – ATA Controller Board; logic boards and remove the board from the server.; Figure 7
- Page 8 – Drive Interconnect Board; Figure 8
- Page 9 – Installing the Replacement Drive Interconnect Board
- Page 11 – Closing the Server; parts can damage it or cause injury.
073-0673 Rev. C
Xserve
Drive Interconnect Board
Replacement Instructions
Follow the instructions in this sheet carefully. Failure to follow these instructions could
damage your equipment and void its warranty.
Note:
Online instructions covering customer-installable parts are available at
http://www.info.apple.com/installparts/.
Tools Required
No tools are required for this procedure. You may, however, find a Phillips screwdriver
useful in releasing the thumbscrews at the front of the server.
Opening the Server
The server slides open from the front of the rack. The top cover remains in place in the
rack while the bottom housing (containing all internal components) should be placed on a
sturdy, flat surface.
1.
Alert users that the server will be unavailable for a period of time.
2.
Shut down the server.
Warning: To avoid damaging internal components or causing injury, always
shut down the server before opening it. After you shut down the server, internal
components can be very hot. Let the server cool down before continuing.
3.
Write down the server’s serial number, which is located on the back panel. If it is
necessary to set up the server’s software after you replace the drive interconnect
board, you will be asked for the serial number at login.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Xserve Drive Interconnect Board - 3 9. Grasp the thumbscrews and slide the bottom housing forward part way to expose the two chassis levers. (Figure 2) 10. While depressing both levers, pull the bottom housing all the way forward and remove it from the rack. Figure 2 11. Place the bottom housing on ...
Xserve Drive Interconnect Board - 4 For each installed drive, do the following: 1. Press the handle on the front of the drive module so the handle pops out. (Figure 3) Figure 3 2. Grasp the drive handle, and pull the drive module out of the server. (Figure 4) Figure 4
Xserve Drive Interconnect Board - 5 Blowers 1. Disconnect the cable for the right blower from the drive interconnect board. (Figure 5) 2. Lift the right blower straight up off its mounting pegs and remove it from the server. 3. Repeat steps 1 and 2 for the left blower. Figure 5