  • Page 2 – Unitary Products Group; DIMENSIONS
  • Page 3 – COOLING CAPACITY; Models
  • Page 4 – ACCESSORIES; TXV Kits; LIMITATIONS; AIR FLOW DATA - 60 Hz MODELS
  • Page 6 – PHYSICAL & ELECTRICAL DATA
  • Page 7 – kW & MBH CONVERSIONS - FOR TOTAL POWER INPUT REQUIREMENT
  • Page 11 – COOLING MODELS WITH ELECTRIC HEAT WIRING; SINGLE-STAGE COOLING WIRING; And Newer UPG Single Stage HP Systems; CONTROL WIRING - AHP or MA Series Air Handler
  • Page 12 – TYPICAL APPLICATIONS
Loading the manual

TECHNICAL GUIDE

SINGLE PIECE AIR HANDLERS

FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS

MODELS: AHP18 THRU 60 AND SHP48 THRU 60

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at
www.ari.org/aridirectory.

ISO 9001

Certified Quality

Management System

255029-YTG-J-1007

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

This fan coil line offers the ultimate in application flexibility.
The AHP (non-variable speed motor) models can be ordered
upflow only or as multi-position. The multi-position model can
be installed in downflow, upflow, horizontal right or left without
the need for additional field installed kits.

The SHP 48 & 60 models are upflow only models designed
into a shorter cabinet than the AHP version, for those special
applications where reduced height is required.

All UPG air handlers and coils utilize a TXV to provide our
customers with the optimum performance and refrigerant
control required for 13+ systems. Air handlers can be ordered
with a R22 TXV factory installed that can be easily converted
to R410A by changing the bolt-on TXV. Air handlers are also
available with “Flex-coils” without a factory installed metering
device. For added flexibility, an R22 or R410A TXV can be
field installed to meet your refrigerant choice.

FEATURES

Thermal Expansion Valve

- Provides the ultimate refrigerant

control required for today’s high efficient product. The UPG
bolt-on TXV provides the added flexibility to convert the air
handler to the required refrigerant. The UPG TXV is a true
bolt-on which does not require brazing to replace or install.

MicroBlue

TM

Coated Fins

- All air handler coils are treated

with the MicroBlue

TM

hydrophilic coating to enhance the

removal of condensate during the refrigeration cycle and
reduce the possibility of water blow-off. The MicroBlue

TM

coating also reduces the growth of germ causing microbes
for a healthier home environment.

Insulated Cabinet

- All air handler cabinets are thermally

insulated with 1” foil faced insulation (R-4.2) to prevent
sweating. For applications in extreme humidity conditions an
optional, field installed, external insulating wrap kit is also
available.

Durable Finish Inside and Out

- Air handler casings are

made of pre-painted galvanized steel which provides a better
paint to steel bond that resists corrosion and rust creep. All
internal coil sheet metal parts are made of G90 pre-painted
steel (i.e. triangular plates, top plates, horizontal supports
etc). Coil header plates are not painted due to the brazing
process during production. The coil header plates are treated
after the brazing process with a corrosion resistant spray to
reduce the probability of rust.

High Efficiency -

5 ton unit has high efficiency DC motor.

New 4 HK Heat Kit -

Installation friendly, easy service, more

robust, unique to new design.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group; DIMENSIONS

255029-YTG-J-1007 2 Unitary Products Group DIMENSIONS 10-3/8” F CIRCUIT BREAKER PANEL BOTTOM INLET DIMENSIONS DRAIN PAN CONNECTIONSFOR HORIZONTAL APPLICATIONS J BLOWERCOMPARTMENT REFRIGERANTCONNECTIONS DRAIN CONNECTIONS FOR UPFLOW AND DOWNFLOW APPLICATIONS 7-11/32” D B A K C 1-1/2” 18-9/32” E TOP OU...

Page 3 - COOLING CAPACITY; Models

255029-YTG-J-1007 Unitary Products Group 3 COOLING CAPACITY Models Rated CFM Entering Air °F (Dry / Wet Bulb) MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 FULL-CASED “A” TYPE MULTI-POSITION AHP18B2A(N,H)21 650 85/72 24.5 22.3 19.9 17.3 80/6...

Page 4 - ACCESSORIES; TXV Kits; LIMITATIONS; AIR FLOW DATA - 60 Hz MODELS

255029-YTG-J-1007 4 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kits - TXV kits are available for “Flex-coil” applications and converting R22 to R410A or as a service replacement.All kits are bolt-on and require no brazing to install. Non-Combustible Base...