York PV9 - Manual

York PV9

York PV9 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Unitary Products Group; DIMENSIONS
  • Page 3 – HIGH ALTITUDE PRESSURE SWITCH APPLICATION
  • Page 4 – AIR FLOW DATA; HIGH / LOW SPEED COOLING AND HEAT PUMP CFM
  • Page 5 – FILTER PERFORMANCE; The filter pressure drop values in the “Filter Perfor-; Select the filter type.; Airflow Range
  • Page 6 – ACCESSORIES
  • Page 7 – NOTES
  • Page 8 – Copyright
Loading the manual

TECHNICAL GUIDE

AFFINITY

MODELS: PV9

GAS-FIRED
CONDENSING / HIGH EFFICIENCY
TWO STAGE VARIABLE
UPFLOW FURNACES

UP TO 94% AFUE

NATURAL GAS
40 - 120 MBH INPUT

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com for the most
up-to-date technical information.

Additional rating information can be found at
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.

036-21584-001 Rev. B (1004)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.

WARRANTY

Lifetime limited warranty on both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.

10-year warranty on commercial applications.

5-year limited parts warranty.

FEATURES

Two stage heating operation includes:

- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation

Provides increased comfort level & very quiet unit oper-
ation

Adjustable delay timer allows two stage operation with
single stage thermostat

• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• High velocity filter and side -return filter rack provided for

easy field installation.

• May be installed as either two-pipe (sealed combustion)

or single pipe vent (using indoor combustion air)

• Top intake & vent connection allows installation in narrow

locations.

• Electronic Hot Surface Ignition saves fuel cost with

increased dependability and reliability.

• Induced combustion system with inshot main burners for

quiet, efficient operation.

• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-

grade stainless steel.

• Timed on, adjustable off blower capability for maximum

comfort.

• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance

or service.

• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• ClimaTraK comfort system allows dealer to customize

comfort settings based on regional location.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group; DIMENSIONS

036-21584-001 Rev. B (1004) 2 Unitary Products Group Three elbows (two in vent pipe and one in the air intake pipe) are already accounted for and need not be included in the elbow count from the Table above. 30-7/8 21-1/2 13-7/8 7 11 7/8 23-3/4 7/8 30-1/8 26-1/2 24-5/8 A 40 26-1/2 25-3/8 28-3/8 21-1...

Page 3 - HIGH ALTITUDE PRESSURE SWITCH APPLICATION

036-21584-001 Rev. B (1004) Unitary Products Group 3 NOTE: For high altitude conversion, an orifice change may also be required. See Form 035-14447-001 for application information. Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.Wire size and o...

Page 4 - AIR FLOW DATA; HIGH / LOW SPEED COOLING AND HEAT PUMP CFM

036-21584-001 Rev. B (1004) 4 Unitary Products Group AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM 40,000 INPUT - 3 Ton 60,000 INPUT - 3 Ton JUMPER SETTINGS CFM m³/min CFM m³/min High Low High Low High Low High Low COOL Tap ADJ Tap 1340 995 38.0 28.2 1330 900 37.7 25.5 A B 1205 885 34.1 2...

Other York Models