York K4EU090 - Manual

York K4EU090

York K4EU090 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – 36-21300-002-A-0905; TABLE OF CONTENTS; LIST OF FIGURES
  • Page 3 – NOMENCLATURE; HOT WATER COILS; APPLICATION FLEXIBILITY
  • Page 4 – FIGURE 1 - VERTICAL AND HORIZONTAL
  • Page 6 – TABLE 3: SOUND POWER RATINGS
  • Page 7 – TABLE 4: HEATING CAPACITY - ELECTRIC HEAT ACCESSORY
  • Page 8 – TABLE 5: STEAM COIL CAPACITY; TABLE 6: HOT WATER CAPACITY
  • Page 14 – TABLE 15: SUPPLY AIR PLENUM PERFORMANCE DATA; TABLE 16: BLOWER MOTOR AND DRIVE DATA
  • Page 15 – TABLE 17: KEU PHYSICAL DATA
  • Page 16 – ACCESSORIES; FIGURE 1 - UNIT DIMENSIONS KEU060
  • Page 19 – FIGURE 5 - ACCESSORY DIMENSIONS
  • Page 20 – FIGURE 6 - RETURN AIR GRILL; FIGURE 7 - BASE ACCESSORY
  • Page 21 – FIGURE 8 - STEAM COIL; FIGURE 9 - HOT WATER COIL
  • Page 22 – TABLE 22: KEU ELECTRICAL DATA
  • Page 24 – FIGURE 10 - FIELD WIRING FOR POWER SUPPLY; COOLING ONLY UNITS AN; FIGURE 11 - COOLING ONLY UNIT; FIGURE 12 - UNIT WITH STEAM OR HOT WATER COIL ACCESSORY
  • Page 25 – FIGURE 13 - FIELD WIRING FOR UNITS WITH ELECTRIC HEAT
Loading the manual

®

Technical Guide

SPLIT-SYSTEM

EVAPORATOR BLOWERS

K2EU060, K4EU090, K3EU120 &

K3EU180

5 THRU 15 NOMINAL TONS

036-21300-002-A-0905

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These completely assembled units include a well-insulated cabinet, a
DX cooling coil with copper tubes and aluminum fins, expansion
valve(s), distributor(s), throwaway filters, a centrifugal blower, a blower
motor, an adjustable belt drive, a blower motor contactor and a small
holding charge of refrigerant-22.

The units are shipped in the vertical position ready for field installation.
They can be installed for horizontal operation by reversing the position
of the solid bottom panel with the return air duct flange on the front of
the unit.

ACCESSORIES—FIELD INSTALLED

SUPPLY AIR PLENUMS

These fully insulated plenums are available for free standing units
located within the conditioned space, are shipped knocked-down for
easy field assembly, are finished to match the exterior of the basic
unit, and have double deflection grills that can be adjusted to vary the
throw, spread and drop of the supply air.

RETURN AIR GRILLS

These expanded metal grills are available for free standing units
located within the conditioned space, are finished to match the exterior
of the basic unit and are shipped in one piece for easy installation.

BASES

Bases are available to raise vertical units above the floor. Outdoor air
may be introduced through these bases by cutting an access opening
to accommodate the outdoor air duct connection. These bases are fin-
ished to match the exterior of the basic unit. They may have to be insu-
lated in the field for certain applications.

THREE-PHASE ELECTRIC HEATERS

Electric heaters are available in several capacities to provide maxi-
mum flexibility. Both the air conditioning unit and the heater can be
selected to precisely match the cooling and heating requirements of
the conditioned space. These heaters are designed for easy field
installation over the supply air opening of the unit. They have been
tested by and will be shipped with a CSA label. Every heater will be
fully protected against excessive current and temperature by fuses
and two high limit thermostats.

Units with electric heat will require only one power supply for both the
heating elements and the supply air blower motor, and the power wir-
ing can be protected by either dual element/time delay fuses or an
inverse time circuit breaker.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - 36-21300-002-A-0905; TABLE OF CONTENTS; LIST OF FIGURES

036-21300-002-A-0905 2 Unitary Products Group TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ACCESSORIES—FIELD INSTALLED . . . . . . . . . . . . . . . . 1 NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 APPLICATION...

Page 3 - NOMENCLATURE; HOT WATER COILS; APPLICATION FLEXIBILITY

036-21300-002-A-0905 Unitary Products Group 3 NOMENCLATURE ACCESSORIES-FIELD INSTALLED (CONT.) HOT WATER COILS These drainable coils have 2 rows of 1/2" copper tubes, 12aluminum fins per inch, a casing that is finished to match theexterior of the basic unit, but no water control valve. The coils...

Page 4 - FIGURE 1 - VERTICAL AND HORIZONTAL

036-21300-002-A-0905 4 Unitary Products Group MODEL 15 TON These units have two distinct modules . . . a blower moduleand a coil module. Although the unit is always shipped in thevertical position with a vertical air discharge as shown in illus-tration (a), the blower module can be repositioned in t...