Table of Contents:
- Page 2 – Model
- Page 3 – Model Coil
- Page 4 – AIR; COOLING CAPACITY - COIL ONLY
- Page 5 – Unitary Products Group; APPLICATION LIMITATIONS; uncased upflow; APPLICATION FACTOR-RATED CFM VS. ACTUAL CFM; CAPACITY FACTOR; Entering Air Temperature Limits
- Page 8 – PHYSICAL DATA
- Page 11 – DIMENSIONS; Dimensions - MC Coils
- Page 13 – INLET; Dimensions - HD Coils
- Page 14 – NOTES
- Page 16 – Copyright
ADD - ON COILS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: MC, PC, FC, HD, HC, UC
600 - 2000 CFM 1.5 - 5 TON COILS
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
HORIZONTAL CASED
HC
FULL CASED
MULTI-POSITION
MC
UPFLOW
PARTIAL CASED
PC
HORIZONTAL
DUCT
HD
UPFLOW UNCASED
UC
UPFLOW/DOWNFLOW
FULL CASED
FC
ISO 9001
Certified Quality
Management System
258931-BTG-A-0606
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL
GUIDE
TECHNICAL
GUIDE
DESCRIPTION
These cooling and heat pump coils are designed to be installed with
UPG furnaces and to be matched with UPG cooling and heat pump
outdoor units. All UPG coils utilize a TXV to provide our customers
with the optimum performance and refrigerant control required for
13+ SEER systems. Coils can be ordered with a R22 TXV factory
installed that can be easily converted to R410A by changing the bolt-
on TXV.
“Flex-coils”
are also available without a factory installed metering
device. For added application flexibility a R22 or R410A TXV is
installed, on
“Flex-coils”,
in the field to meet your refrigerant choice.
Upflow/Downflow Coils Full Cased and Partial Cased
Coils –
Designed for high-efficiency to match any system, full cased
in the upflow or downflow and the partial cased in the upflow only
application
.
Multi-Position Coils -
Designed for high-efficiency like the
upflow/downflow coil but with the added flexibility that allows it to be
installed any position, upflow, downflow, horizontal right or left. This
coil can be easily applied to our furnace and modular air handler in
any configuration.
Horizontal Duct Coils -
Available for both cooling and heat pump
dedicated horizontal, slab coil, applications. Field transition may be
required
.
Dedicated Horizontal Cased Coils –
These coils are cooling
only or heat pump approved for horizontal furnace or modular air
handler applications. Unlike the horizontal duct coils these cased
coils match the dimensions of the furnace or modular blower
.
FEATURES
Thermal Expansion Valve -
Provides flexibility to convert any
coil to R22 or R410A refrigerant. A true bolt-on TXV, valve assembly
and equalizer tube are bolt-on, no brazing required. TXV and sens-
ing bulb are mounted inside the cased coil cabinet. (Must be field
supplied for all “Flex-coils”)
MicroBlue™ Coated Fins -
All coils are treated with a
MicroBlue™
Hydrophilic coating to enhance the removal of conden-
sate during the refrigeration cycle and reduce the possibility of water
blow-off. The
MicroBlue™
coating also reduces the growth of germ
causing microbes.
Insulated Cabinet -
All evaporator coil cabinets are thermally
insulated with foil faced insulation to prevent sweatin
g.
Internally Clean -
All evaporator coils are factory leak-tested,
dehydrated, sealed and shipped with a holding charge. The suction
and liquid lines are sealed with rubber plugs, no cutting of connection
stubs to attach line set
.
Durable Finish Inside and Out -
Coil casings are made of pre-
painted steel. The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep. All inter-
nal metal parts are made of G90 pre-painted steel i.e. triangular
plates, top plates, horizontal supports etc. (Coil header plates are
non-painted due to the brazing process during production.)
Optimum Heat Transfer -
Using the latest in heat transfer tech-
nology, staggered rows of copper tubes are mechanically expanded
into aluminum fins to provide optimum air to surface contact for
ample moisture removal as well as high performance ratings.
ACCESSORIES
Refer to Price Manual for specific model numbers.
TXV Kits
-
Thermal expansion valve kits are available for “Flex-coil”
applications and converting R22 to R410A refrigerant or as a service
replacement. All TXV kits are non-braze
,
all connections are bolt-on
including the valve assembly and equalizer tube. (No orifice or any
other metering device is to used in conjunction with the TXV).
Coil Casing Without Coil
–
Coil casings are available in each
width that can be installed with the furnace or modular air handler
during initial installation. This option is available to allow the installer
the flexibility to install the coil at a later date without duct modifica-
tions.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
258931-BTG-A-0606 2 Unitary Products Group COOLING CAPACITY - Coil Only * Model Rated CFM Entering Air ° F (Wet Bulb) MBH @ Evaporator Temperature and Corresponding Pressure °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 UPFLOW "A" TYPE FC18A PC18A 675 72 25.3 23.1 20.6 17.9 67 23.4 21.1 ...
258931-BTG-A-0606 Unitary Products Group 3 COOLING CAPACITY - COIL ONLY * Model Coil Rated CFM Entering Air °F (Wet Bulb) MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 FULL-CASED “A” TYPE MULTI-POSITION MC18A 550 72 25.8 23.5 21.0 18.2 67 23...
258931-BTG-A-0606 4 Unitary Products Group Notes: • MC coils available with a factory installed horizontal drain pan option (H). COOLING CAPACITY - Coil Only * MODEL RATED CFM ENTERING AIR ° F (Wet Bulb) MBH @ Evaporator Temperature and Corresponding Pressure °F/ PSIG 35 / 61.5 40 / 68.5 45 / 76.0 5...