  • Page 2 – Unitary Products Group; Physical and Electrical Data - 1 Phase; MODEL
  • Page 3 – Outdoor Unit; Indoor Coil
  • Page 6 – COOLING CAPACITY - With Air Handler Coils
  • Page 7 – COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
  • Page 10 – COOLING CAPACITY - With Variable Speed Furnaces
  • Page 12 – SOUND POWER RATINGS; Liquid
  • Page 13 – TYPICAL INSTALLATION; NOTE: ALL OUTDOOR WIRING
  • Page 14 – COOLING PERFORMANCE DATA; AIR CONDITIONER MODEL NO.; ENTERING AIR; Coil; KW
  • Page 24 – Copyright; MATCHING INDOOR COMPONENTS; * Available with factor; FOR NON-FURNACE APPLICATIONS
Loading the manual

TECHNICAL GUIDE

SPLIT-SYSTEM
AIR CONDITIONERS

12 SEER

MODELS:
H*RC018 THRU 060
(1.5 THRU 5 NOMINAL TONS, 1 PH)

H*RC036S(25,46) THRU 060
(3 THRU 5 NOMINAL TONS, 3 PH)

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com for the most
up-to-date technical information.

Additional rating information can be found at
www.ariprimenet.org.

LISTED

CERTIFICATION APPLIES ONLY

WHEN THE COMPLETE

SYSTEM IS LISTED

WITH ARI.

ISO 9001

Certified Quality

Management System

R

N

E

M

P

I

U

Q

E

T

Y

R

AT

I

N

U

0

1

2

A R

I

R

A

D

N

A

T

S

D

I

S

N

O

T

C

E

S

F

O

C

C

I

F

I

T

R

E

N

O

I

T

A

H T

I

W

C

G N

I

YL

P

M

O

S

A

I

R

A

O

T

D

E

I

F

I

T

R

E

C

R

E

R

UT

C

A

F

U

N

A

M

C

-

G

N I

N O

I

TI

D

N

O

R

I

A

036-21137-004 Rev. C (0505)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The 12 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, each designed to serve a specific function. Match-
ing Air Handlers are available for upflow, downflow or hori-
zontal applications to provide a complete system. Electric
Heaters are available if required. Add-On coils are available
for use with upflow, downflow or horizontal furnaces and air
handlers.

WARRANTY

Single Phase Units:
5-year limited parts warranty.
10-year limited compressor warranty.
Three Phase Units:
1-year limited parts warranty.
5-year limited compressor warranty.

FEATURES

QUALITY CONDENSER COILS - The coil is constructed

of enhanced copper tube and aluminum fins.

COIL PROTECTION - Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.

PROTECTED COMPRESSOR - The compressor is inter-

nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.

DURABLE FINISH - The cabinet is made of pre-painted

steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted textured champagne
finish insure less fading when exposed to sunlight.

LOWER INSTALLED COST - Installation time and costs

are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Available in sweat connect models only.
The unit contains enough refrigerant for matching indoor
coils and 15 feet of interconnecting piping. The small base
dimension means less space is required on the ground or
roof.

TOP DISCHARGE - The warm air from the top mounted

fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.

LOW OPERATING SOUND LEVEL - The upward air flow

carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.

LOW MAINTENANCE - Long life permanently lubricated

motor-bearings need no annual servicing.

EASY SERVICE ACCESS - Fully exposed refrigerant con-

nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.

SECURED SERVICE VALVES - Secured re-usable ser-

vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.

U.L. and C.U.L. listed - approved for outdoor application.

Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group; Physical and Electrical Data - 1 Phase; MODEL

036-21137-004 Rev. C (0505) 2 Unitary Products Group Physical and Electrical Data - 1 Phase MODEL H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06 Unit Supply Voltage 208/230 – 1 – 60 Normal Voltage Range 187 to 252 Minimum Circuit Ampacity 1 10.1 14.1 16.5 19.7 26.2 28.5...

Page 3 - Outdoor Unit; Indoor Coil

036-21137-004 Rev. C (0505) Unitary Products Group 3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06 Unit Orifice (s) 1 53 59 63 73 78 87 – Factory R-22 Charge, lbs-oz. 4 - 9 4 - 7 5...

Page 6 - COOLING CAPACITY - With Air Handler Coils

036-21137-004 Rev. C (0505) 6 Unitary Products Group - = Not applicable. COOLING CAPACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEAT KW W RATED CFM NET MBH SEER W/O TXV SEER WITH TXV 3 EER TOTAL SENS. 1 PH 12 SEER AC WITH N1AH / G2FD H2RC018S06 N1AHB08...