York H*RA036 THRU 090 - Manual

York H*RA036 THRU 090

York H*RA036 THRU 090 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – Unitary Products Group; Physical and Electrical Data - 1 Phase; Physical and Electrical Data - 3 Phase; MODEL
  • Page 3 – COOLING CAPACITY - With Air Handler Coils
  • Page 6 – COOLING PERFORMANCE
  • Page 7 – Hard Start Kit; - Provides increased starting torque for areas; Off Cycle Timer Delay; vent rapid recycling of the compressor.; Room Thermostats; TYPICAL INSTALLATION; UNIT MODEL; THERMOSTAT; NOTE: ALL OUTDOOR WIRING MUST
  • Page 8 – TYPICAL FIELD WIRING - 1 Phase Application
  • Page 9 – COOLING PERFORMANCE DATA; AIR CONDITIONER MODEL NO.; CONDENSER; Air Handler
  • Page 12 – Phase
  • Page 17 – Coil
  • Page 19 – MATCHING INDOOR COMPONENTS; FOR NON-FURNACE APPLICATIONS
  • Page 20 – NOTES
Loading the manual

TECHNICAL GUIDE

SPLIT-SYSTEM AIR CONDITIONERS
10 SEER
MODELS:
H*RA018 THRU 060
(1.5 THRU 5 NOMINAL TONS, 1 PH)
H*RA036 THRU 090
(3 THRU 7.5 NOMINAL TONS, 3 PH)

MODELS: 018 - 060 (1 PH & 3 PH)

MODELS: 076 - 090 (3 PH)

Due to continuous product improvement, specifica-
tions are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.

R

N

E

M

P

I

U

Q

E

T

Y

R

AT

I

N

U

0

1

2

A R

I

R

A

D

N

A

T

S

D

I

S

N

O

T

C

E

S

F

O

C

C

I

F

I

T

R

E

N

O

I

T

A

H T

I

W

C

G N

I

YL

P

M

O

S

A

I

R

A

O

T

D

E

I

F

I

T

R

E

C

R

E

R

UT

C

A

F

U

N

A

M

C

-

G

N I

N O

I

TI

D

N

O

R

I

A

CERTIFICATION APPLIES ONLY

WHEN THE COMPLETE

SYSTEM IS LISTED

WITH ARI.

LISTED

®

036-21121-002 Rev. A (0602)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The 10 SEER Series condensing unit is the outdoor part of a

versatile system of air conditioning. It is designed to be cus-

tom-matched with one of UPG’s complete line of evaporator

sections, each designed to serve a specific function. Match-

ing Air Handlers are available for upflow, downflow or hori-

zontal applications to provide a complete system. Electric

Heaters are available if required. Add-On coils are available

for use with upflow, downflow or horizontal furnaces and air

handlers.

WARRANTY

Single Phase Units:

5-year limited parts warranty.

5-year limited compressor warranty.

Three Phase Units:

1-year limited parts warranty.

5-year limited compressor warranty.

FEATURES

QUALITY CONDENSER COILS -

The coil is constructed

of enhanced copper tube and aluminum fins.

COIL PROTECTION -

Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC

coated steel coil guard.

PROTECTED COMPRESSOR -

The compressor is inter-

nally protected against high pressure and temperature.

This is accomplished by the simultaneous operation of

high pressure relief valve and a temperature sensor which

protects the compressor if undesirable operating condi-

tions occur. A liquid line filter-drier further protects the

compressor.

DURABLE FINISH -

The cabinet is made of pre-painted

steel. The pre-treated flat galvanized steel provides a bet-

ter paint to steel bond, which resists corrosion and rust

creep. Special primer formulas and matted desert sand fin-

ish insure less fading when exposed to sunlight.

LOWER INSTALLED COST -

Installation time and costs

are reduced by easy power and control wiring connec-

tions. Discharge line heat exchanger knockouts are pro-

vided, if required. Available in sweat connect models only.

The unit contains enough refrigerant for matching indoor

coils and 15 feet of interconnecting piping. The small base

dimension means less space is required on the ground or

roof.

TOP DISCHARGE -

The warm air from the top mounted

fan is blown up away from the structure and any landscap-

ing. This allows compact location on multi-unit applica-

tions.

LOW OPERATING SOUND LEVEL -

The upward air flow

carries the normal operating noise up away from the living

area. The rigid top panel effectively isolates any motor

sound. Isolator mounted compressor and the rippled fins

of the condenser coil muffle the normal fan motor and

compressor operating sounds.

LOW MAINTENANCE -

Long life permanently lubricated

motor-bearings need no annual servicing.

EASY SERVICE ACCESS -

Fully exposed refrigerant con-

nections, a single panel covering the electrical controls

and the molex plug in the control box connecting the con-

denser fan, make for easy servicing of the unit.

SECURED SERVICE VALVES -

Secured re-usable ser-

vice valves are provided on both the liquid and vapor

sweat connections for ease of evacuating and charging.

U.L. and C.U.L.

listed - approved for outdoor application.

Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group; Physical and Electrical Data - 1 Phase; Physical and Electrical Data - 3 Phase; MODEL

036-21121-002 Rev. A (0602) 2 Unitary Products Group 1. Rated in accordance with ARI Standard 110, utilization range “A”.2. Dual element fuses or HACR circuit breaker.3. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls. 4. ...

Page 3 - COOLING CAPACITY - With Air Handler Coils

036-21121-002 Rev. A (0602) Unitary Products Group 3 COOLING CAPACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEAT KW W RATED CFM NET MBH SEER W/O TXV SEER + TXV 3 EER TOTAL SENS. 1 PH 10 SEER AC WITH N1AH / G2FD H1RA018S06 N1AHB0806 2,5,8,10 17 G2FD024S...

Page 6 - COOLING PERFORMANCE

036-21121-002 Rev. A (0602) 6 Unitary Products Group NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat.2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increase capacity 1% for each 2° increase in sub-cooling. b. Decrease ...

Other York Models

All York Other