York GY9S-UP - Manual
York GY9S-UP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Johnson Controls Unitary Products
- Page 3 – ELECTRICAL AND PERFORMANCE DATA
- Page 4 – BLOWER PERFORMANCE CFM
- Page 5 – FILTER PERFORMANCE; RECOMMENDED FILTER SIZES
- Page 6 – Thermostat Chart
- Page 7 – ACCESSORIES
- Page 8 – Copyright; NOTES
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL GUIDE
MODELS: GY9S-UP
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW FURNACES
92% TO 94% AFUE
NATURAL GAS
40 - 135 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
277805-YTG-A-1106
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
•
Compact, easy to install, ideal height 40" cabinet
•
Blower-off delay for cooling SEER improvement.
•
Easy to connect power/control wiring.
•
Built-in, high level self diagnostics with fault code display.
•
Low unit amp requirement for easy replacement applica-
tion.
•
Integrated control module for reliable, economical opera-
tion.
•
May be installed as either two-pipe (sealed combustion)
or single pipe vent (using indoor combustion air)
•
Top intake & vent connection allows installation in narrow
locations.
•
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
•
Induced combustion system with inshot main burners for
quiet, efficient operation.
•
No special vent termination kit required.
•
100% shut off main gas valve for extra safety.
•
PSC four speed, direct drive motor with large, quiet
blower.
•
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
•
Hi-tech tubular aluminized steel primary heat exchanger.
•
Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
•
Timed on, adjustable off blower capability for maximum
comfort.
•
Solid removable bottom panel allows easy application.
•
Easy access from front of unit for cleaning, maintenance
or service.
•
Protection from intake, exhaust or condensate blockage.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Johnson Controls Unitary Products 277805-YTG-A-1106 30-7/8 21-1/2 13-7/8 7 11 7/8 23-3/4 7/8 28-1/2 26-1/2 24-5/8 A 40 26-1/2 25-3/8 28-3/8 21-1/2 11 8 26-3/4 1-1/2 1-1/4 C 24-3/8 20 5/8 5/8 B 24-7/16 2 D 1-1/2” GASPIPE ENTRY 7/8” JUNCTIONBOX HOLE T-STAT WIRING7/8” K.O. CONDENSATEDRAIN 7/8” K.O. O...
Johnson Controls Unitary Products 3 277805-YTG-A-1106 Nominal external static pressure is 0.50” w.c. at furnace outlet ahead of cooling coils.Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.Wire size and over current protection must comply with...
4 Johnson Controls Unitary Products 277805-YTG-A-1106 NOTES: 1. Airflow expressed in standard cubic feet per minute (CFM).2. Return air is through side opposite motor (left side) for one side return (worst case).3. Airflows above 1800 CFM require either return from two sides or one side plus bottom....