  • Page 2 – Unitary Products Group; FIRE OR EXPLOSION HAZARD
  • Page 3 – Examine the furnace casing for obvious signs of deterioration.; Furnace Examination Checkpoints - Downflow
  • Page 4 – Operating Instructions:; FURNACE USER MAINTENANCE
  • Page 5 – Air Filters; Externally Mounted Air Filters
  • Page 6 – Blower Care; SECTION II: SERVICE AND MAINTENANCE; SAFETY SECTION; Burner Removal/Cleaning; ELECTRIC SHOCK, FIRE OR EXPLOSION HAZARD
  • Page 7 – Cleaning the Heat Exchanger; Lower Heat Exchanger Access; SEQUENCE OF OPERATION; Continuous Blower
  • Page 8 – Hot Surface Ignition System; TROUBLESHOOTING; CONTINUOUS FLASH; Never adjust pressure switch to allow furnace operation.
  • Page 9 – FLASH
  • Page 10 – SECTION III: REPLACEMENT PARTS LIST; Heat Exchanger Assembly; ITEM
  • Page 11 – Field Installed Accessories-Non-Electrical; REPLACEMENT PART CONTACT INFORMATION; York International
  • Page 12 – SECTION IV: WIRING DIAGRAM; Wiring Diagram
  • Page 13 – NOTES
  • Page 16 – Copyright; Limited Warranty; Cleaning or replacement of filters.
Loading the manual

035-19992-001 Rev. A (0404)

USER’S INFORMATION,

MAINTENANCE AND

SERVICE MANUAL

MODELS: G8C/ GF8

(Single Stage Multi-Position)

EFFICIENCY
RATING
CERTIFIED

This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.

The manufacturer recommends that the user read all sec-
tions of this manual and keep the manual for future refer-
ence.

SECTION I: USER’S INFORMATION

SAFETY

1.

The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.

2.

Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.

3.

The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.

4.

Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 4 of this manual when lighting the furnace or turning the
furnace off.

5.

Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.

6.

Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.

FIRE OR EXPLOSION HAZARD -

Failure to follow safety

warnings exactly could result in serious injury, death, or prop-
erty damage.

Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other
appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone
(including cell phone) in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire depart-
ment.

Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

CONTACT INFORMATION

Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions.

Contact us by mail:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

TABLE OF CONTENTS

CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

USER’S INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
DESCRIPTION (50-125 MBH INPUT MODELS) . . . . . . . . . . . . . . . 2
DESCRIPTION (150 MBH INPUT MODELS) . . . . . . . . . . . . . . . . . . 2
INSTRUCTIONS FOR EXAMINING THE FURNACE
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . 4
START-UP AND SHUTDOWN INSTRUCTIONS . . . . . . . . . . . . . . . 4

Read the Instructions Below Before Trying to Start the Furnace . . 4
Operating Instructions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
To Turn Off the Appliance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . 4

Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Removing Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Blower Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Motor Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

SERVICE AND MAINTENANCE MANUAL . . . . . . . . . . . . . . . . . . . . 6

SAFETY SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
FURNACE MAINTENANCE SECTION . . . . . . . . . . . . . . . . . . . . . . .6
FURNACE CLEANING SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Burner Removal/Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning the Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Continuous Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Intermittent Blower - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Heating Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Hot Surface Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . .8

REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

FIELD INSTALLED ACCESSORIES - NON-ELECTRICAL . . . . . .11

REPLACEMENT PART CONTACT INFORMATION . . . . . . . . . . . . .11
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group; FIRE OR EXPLOSION HAZARD

035-19992-001 Rev. A (0404) 2 Unitary Products Group 7. NEVER … Store flammable materials of any kind near your fur- nace. Gasoline, solvents, and other volatile liquids should bestored only in approved containers outside your home. Thesematerials vaporize easily and are extremely dangerous. 8. NEVE...

Page 3 - Examine the furnace casing for obvious signs of deterioration.; Furnace Examination Checkpoints - Downflow

035-19992-001 Rev. A (0404) Unitary Products Group 3 INSTRUCTIONS FOR EXAMINING THE FURNACE INSTALLATION It is the owner’s responsibility to ensure that an annual inspection of theentire heating portion of the unit is made by a qualified service agency.Examine the furnace as outlined below in steps ...

Page 4 - Operating Instructions:; FURNACE USER MAINTENANCE

035-19992-001 Rev. A (0404) 4 Unitary Products Group HOW YOUR GAS FURNACE WORKS Your furnace is a very easy appliance to take for granted. Season afterseason, it sits there in your home, keeping you warm and comfortable.For this reason, you may never have given much thought to the wayyour furnace op...

Other York Models