York E2FB120 - Manual
York E2FB120 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; INSTALLATION
- Page 3 – GROUND LEVEL LOCATIONS; RIGGING AND HANDLING; TABLE 1
- Page 4 – CLEARANCES; WARNING: Do not permit overhanging structures or shrubs to; COMPRESSORS; CAUTION: Do Not loosen compressor mounting bolts.; COMPRESSOR CRANKCASE HEATER; CAUTION: Do not attempt to start the compressor without at; POWER AND CONTROL WIRING; POWER WIRING; TABLE 2
- Page 5 – WIRE SIZING; REFRIGERANT PIPING; GENERAL GUIDELINES; - TYPICAL FIELD WIRING; TABLE 3; Total Circuit Length
- Page 6 – - UNIT DIMENSIONS AND CLEARANCES
- Page 7 – LINE SIZING; Oil return will be critical during:; TABLE 4; - FIELD PIPING DIAGRAMS
- Page 8 – SERVICE VALVES; EXTENDING THE SERVICE PORTS; TABLE 5
- Page 9 – EVACUATING AND CHARGING
- Page 10 – BALANCE POINT SETTING; The balance point of a heat pump is the lowest temperature at; The outdoor design temperature,; b i e n t b a l a n c e p o i n t c o n t r o l a c c e s s o r y M o d e l N o .; - EXTENDING THE SERVICE PORTS
- Page 11 – - REFRIGERANT FLOW DIAGRAM
- Page 13 – COOLING OPERATION; OPERATION
- Page 14 – DEFROST CYCLE; When condensate freezes on the outdoor coil during heating; OPERATION BELOW 0; When the system switch on the room thermostat is placed in
- Page 15 – CRANKCASE HEATER; CAUTION: DO NOT ATTEMPT TO START THE COMPRES-; SAFETY FEATURES; CLEANING; NOTICE TO OWNER; MAINTENANCE
GENERAL
These heat pump units are designed for outdoor installation on
a roof or at ground level. Every unit is completely piped and
wired at the factory and is shipped ready for immediate installa-
tion. Only the liquid and vapor lines to the indoor coil, the con-
trol wiring and the main power wiring are required to complete
the installation. Each unit is dehydrated, evacuated, leak
tested and pressure tested at 450 psig before being pressur-
ized with a holding charge of Refrigerant-22 for shipment
and/or storage.
Every unit includes a heavy-duty compressor with line break
overload protection, a suction line accumulator, a 4-way re-
versing valve, a filter-drier, an expansion valve, a distributor, a
check valve, and a copper tube/aluminum fin coil.
All controls are readily accessible for maintenance, adjustment
and service. All power and control wiring can be routed through
the front of the unit.
REFERENCE
This instruction covers the installation of the outdoor unit. For
information on the installation of the matching indoor unit, refer
to Form 515.41-N2.
All accessories come with a separate installation manual.
Refer to Parts Manual for complete listing of replacement parts
on this equipment.
The above forms may be ordered from:
Standard Register
TOLL FREE Telephone: 877-318-9675
TOLL FREE Fax: 877-379-7920
Installer should pay particular attention to the words: NOTE,
CAUTION and WARNING. Notes are intended to clarify or
make the installation easier. Cautions are given to prevent
equipment damage. Warnings are given to alert the installer
that personal injury and/or equipment damage may result if the
installation procedure is not handled properly.
INSPECTION
As soon as a unit is received, it should be inspected for possi-
ble damage during transit. If damage is evident, the extent of
the damage should be noted on the carrier's freight bill. A sepa-
rate request for inspection by the carrier's agent should be
made in writing. See Form 50.15-NM for more information.
SPLIT-SYSTEM HEAT PUMPS
OUTDOOR UNITS
INSTALLATION MANUAL
Supersedes: 035-15410-002-A-0304
035-15410-002-B-0404
MODELS E3FB090 & E2FB120
(50 and 60 Hz)
®
CAUTION
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE
WITH THE ENCLOSED INSTALLATION INSTRUCTIONS AND
ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES
INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRICAL,
AND MECHANICAL CODES.
WARNING
INCORRECT INSTALLATION MAY CREATE A CONDITION
WHERE THE OPERATION OF THE PRODUCT COULD CAUSE
PERSONAL INJURY OR PROPERTY DAMAGE.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Unitary Products Group 035-15410-002-B-0404 E 3 F B 2 5 9 A PRODUCT NOMENCLATURE PRODUCT GENERATION 1 = First Generation 2 = Second Generation 3 = Third Generation PRODUCT CATEGORY E = Split-System Heat Pump Outdoor Unit PRODUCT IDENTIFIER FB = Outdoor Unit VOLTAGE CODE 25 = 208/230-3-60 46 = 460-...
LIMITATIONS These units must be installed in accordance with all national and local safety codes. If no local codes apply, installation must conform with the appropriate national codes. See Table 1 for unit application data. Units are designed to meet National Safety Code Standards. If components ar...
Units may also be moved or lifted with a fork-lift. Slotted open- ings in the base rails are provided for this purpose. The 7-1/2 ton unit may be lifted from either the LH or RH side - under the unit.LENGTH OF FORKS MUST BE A MINIMUM OF 42" (for 7-1/2 ton units) and a MINIMUM OF 54" (for 10 ...