Table of Contents:
- Page 2 – TABLE OF CONTENTS; LIST OF FIGURES; SIMPLICITY; LIST OF TABLES
- Page 3 – PRODUCT NOMENCLATURE
- Page 4 – FEATURES; Simplicity
- Page 5 – Electric Heat Operation; - York’s SunlineTM series units offer factory; FACTORY-INSTALLED OPTIONS; with fully modulating spring-return motor actuator capa-; POWER EXHAUST; - Our single economizer options are; MOTORIZED OUTDOOR AIR INTAKE DAMPER; - Special coating process that utilizes; FIGURE 1 - UNIT CUTAWAY; UNIT SHOWN
- Page 7 – FIELD-INSTALLED ACCESSORIES
- Page 9 – TABLE 1: SOUND POWER RATING; TABLE 3: GAS HEAT RATIINGS
- Page 16 – Example 1; tion is given so 70°F is assumed.; TABLE 7: ALTITUDE CORRECTION FACTORS
- Page 17 – FIGURE 2 - ALTITUDE/TEMPERATURE CONVERSION FACTOR
- Page 18 – COOLING ONLY 180 MBH - BOTTOM DUCT CONNECTIONS
- Page 19 – 40 MBH - BOTTOM DUCT CONNECTIONS
- Page 20 – 80 MBH - BOTTOM DUCT CONNECTIONS
- Page 22 – 00 MBH - BOTTOM DUCT CONNECTIONS
- Page 23 – TABLE 13: BLOWER MOTOR AND DRIVE DATA; TABLE 15: POWER EXHAUST PERFORMANCE
- Page 28 – MODELS
- Page 29 – SUPPLY FAN MOTOR; TABLE 25: ELECTRIC HEAT CORRECTION; NOMINAL VOLTAGE; FIGURE 3 - TYPICAL DM FIELD WIRING DIAGRAM; CONTROL WIRING
- Page 30 – TABLE 26: UTILITIES ENTRY DATA; HOLE
- Page 31 – REAR VIEW DIMENSIONS; For bottom duct applications:; Connect ductwork to the flanges on those panels.; REAR
- Page 32 – Locate unit so that the vent air outlet hood is at least:; TABLE 27: MINIMUM CLEARANCES
- Page 33 – FIGURE 7 - CENTER OF GRAVITY
- Page 34 – FIGURE 9 - FOUR AND SIX POINT LOADS; TABLE 28: FOUR AND SIX POINT LOADS
- Page 35 – FIGURE 10 -UNIT ROOF CURB DIMENSIONS; FIGURE 11 -ROOF CURB DUCT OPENINGS
- Page 36 – CONTROL WIRING DIAGRAM; OCC
- Page 37 – GUIDE SPECIFICATIONS; GENERAL; UNIT CABINET
- Page 38 – REFRIGERANT COMPONENTS; All models shall have two independent circuits.; UNIT CONTROLS; Induced draft motor speed sensor.; UNIT OPERATING CHARACTERISTICS
262259-YTG-B-0107
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL GUIDE
SINGLE PACKAGE GAS/ELECTRIC UNITS
AND SINGLE PACKAGE AIR
CONDITIONERS
DM 180, 240 & 300
15, 20 & 25 NOMINAL TONS
®
DESCRIPTION
YORK Sunline 2000™ units are convertible single package
high efficiency rooftops. All models have independent dual
refrigerant circuits for efficient part load operation. Although
the units are primarily designed for curb mounting on a roof,
they can also be slab-mounted at ground level or set on steel
beams above a finished roof.
All units include:
•
Powder Paint finish that meets ASTM-B-117 1000 hour
salt spray standards
•
Two-stage cooling provided by dual independent
refrigeration circuits with expansion valves, filter-driers,
high and low pressure/loss of charge switches and
freezestats
•
Scroll compressors (25T model only)
•
Two-stage heating provided by dual independent heat
exchangers with aluminized steel tubes, redundant gas
valves, spark ignition with induced draft logic
•
Permanently lubricated motors
•
Bottom or side air discharge configuration capability
(field convertible)
•
Belt Drive Blower Motor with high static drive option
•
Constant supply air volume (CV) with optional variable
air volume (VAV)
•
Manufactured under the quality standards of ISO9001
•
Simplicity
® Control Board
•
Zero-25% fixed air damper with hood
•
Copper tube/aluminum fin coils
•
Hinged filter access and tooless latched doors
•
Rigging holes in base rails for lifting
•
Single point power connection
•
Complete factory package - tested, charged and wired
•
CSA agency approvals on all units
WARRANTY
•
One-year parts warranty
•
A Five-year parts warranty on the compressors and
electric heat elements
•
Ten-year parts warranty on the gas-fired heat
exchangers
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
262259-YTG-B-0107 2 Unitary Products Group TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FACTORY-INSTALLED OPTIONS . . . . ....
262259-YTG-B-0107 Unitary Products Group 3 PRODUCT NOMENCLATURE D M 180 N24 A 2 A AA 1 0 1 2 4 A D = A/C, Single Pkg., R-22 Product Category A = Std. Drive Airflow B = Std. Drive/Single Input Econo.C = Std. Drive/Single Input Econo./Power Exhaust (Downflow Only) D = Std. Drive/Motorized DamperN = Hi...
262259-YTG-B-0107 4 Unitary Products Group FEATURES All models are available with a wide variety of factory-mounted options such as stainless steel heat exchangers, phase monitor, dirty filter switch, and coil guard to make them suitable for almost every application. All units are self-contained and...